Installation Instructions

6

 LEVELING AND STABILIZING YOUR 
 DRYER

Stand the dryer upright near the final location and adjust 

the 4 leveling legs, at the corners, to ensure that the dryer 

is level from side to side and front to rear.

9

 ALCOVE OR CLOSET INSTALLATION

• If your dryer is approved for installation in an alcove or 

closet, it will be stated on a label on the dryer back.

• The  dryer  MUST  be  vented  to  the  outdoors.  See  the 

EXHAUST INFORMATION section 6.

• Minimum clearance between dryer cabinet and adjacent 

walls or other surfaces is:

          0 in. either side

          3 in. front

          4 in. rear

• Minimum vertical space from floor to overhead cabinets, 

ceiling, etc. is 52 in.

• Closet  doors  must  be  louvered  or  otherwise  ventilated 

and must contain a minimum of 60 sq. in. of open area 

equally distributed. If the closet contains both a washer 

and a dryer, doors must contain a minimum of 120 sq. in. 

of open area equally distributed.

• The closet should be vented to the outdoors to prevent 

gas pocketing in case of a gas leak in the supply line.

• No other fuel-burning appliance shall be installed in the 

same closet with the dryer.

NOTE:  WHEN  THE  EXHAUST  DUCT  IS  LOCATED  AT  THE 

REAR OF THE DRYER, MINIMUM CLEARANCE FROM THE 

WALL IS 5.5 in.

DO

ELBOW

REQUIRED

ELBOWS

REQUIRED

DON’T

DO NOT USE

EXCESSIVE

EXHAUST

LENGTH

DO NOT

CRUSH

FLEXIBLE

EXHAUST

AGAINST

WALL

DO NOT

SIT DRYER

ON FLEXIBLE

EXHAUST

8

LEVEL

SIDE-TO-SIDE

4 LEVELING

LEGS

LEVEL

FRONT-TO-BACK

Stand the dryer upright near the final location and adjust

the 4 leveling legs, at the corners, to ensure that the dryer

is level from side to side and front to rear.

• For many applications, installing elbows at both the dryer 

and  the  wall  is  highly  recommended  (see  illustrations 

below).  Elbows  allow  the  dryer  to  sit  close  to  the  wall 

without  kinking  and  or  crushing  the  transition  duct, 

maximizing drying performance.

• Avoid resting the duct on sharp objects.
UL-LISTED FLEXIBLE METAL (FOIL-TYPE) TRANSITION DUCT

• In  special  installations,  it  may  be  necessary  to  connect 

the  dryer  to  the  house  vent  using  a  flexible  metal  (foil-

type)  duct.  A  UL-listed  flexible  metal  (foil-type)  duct  may 

be used ONLY in installations where rigid metal or flexible 

metal (semi-rigid) ducting cannot be used AND where a 4” 

diameter can be maintained throughout the entire length 

of the transition duct.

• In  Canada  and  the  United  States,  only  the  flexible  metal 

(foil-type)  ducts  that  comply  with  the  “Outline  for  Clothes 

Dryer Transition Duct Subject 2158A” shall be used.

• Never install flexible metal duct in walls, ceilings, floors or 

other enclosed spaces.

• Total length of flexible metal duct should not exceed 8 feet 

(2.4m).

• Avoid resting the duct on sharp objects.
For best drying performance:

1. Slide one end of the duct over the clothes dryer outlet pipe.

2. Secure the duct with a clamp.

3. With the dryer in its permanent position, extend the duct 

to its full length. Allow 2” of duct to overlap the exhaust pipe. 

Cut off and remove excess duct. Keep the duct as straight 

as possible for maximum airflow.

4. Secure the duct to the exhaust pipe with the other clamp.

Содержание GFDS350GLWW

Страница 1: ...sit our Web site at www GEAppliances com US BEFORE YOU BEGIN Read these instructions completely and carefully IMPORTANT Save these instructions for local inspector s use IMPORTANT Observe all governing codes and ordinances Note to Installer Be sure to leave these instructions with the customer Note to Customer Keep these instructions with your Use and Care Book for future reference Before the old ...

Страница 2: ...EL GAS CODE ANSI Z223 This gas dryer is equipped with a Valve Burner Assem bly for use only with natural gas Using conversion kit WE25X0217 your local service organization can convert this dryer for use with propane LP gas ALL CONVER SIONS MUST BE MADE BY PROPERLY TRAINED AND QUALI FIED PERSONNEL AND IN ACCORDANCE WITH LOCAL CODES AND ORDINANCE REQUIREMENTS The dryer must be disconnected from the ...

Страница 3: ...ealant CAUTION Use adaptors as shown Connector nuts must not be connected directly to pipe threads APPLY PIPE COMPOUND TO THE ADAPTER AND DRYER GAS INLET Tighten the flexible gas line using two adjustable wrenches APPLY PIPE COMPOUND TO ALL MALE THREADS Tighten all connections using two adjustable wrenches Do not overtorque gas connections Check all connections for leaks with soapy solution or equ...

Страница 4: ...LLOWABLE duct length and number of bends of the exhaust system depends upon the type of duct number of turns the type of exhaust hood wall cap and all conditions noted below The maximum duct length for rigid metal duct is shown in the table below EXHAUST LENGTH 4 DIA 4 4 DIA Exhaust Hood Types No of 90º Elbows Rigid Metal 90 Feet 60 Feet 45 Feet 35 Feet 25 Feet 0 1 2 3 4 RECCOMMENDED MAX LENGTH 5 ...

Страница 5: ...azard Do not use duct longer than specified in the exhaust length table Longer ducts can accumulate lint creating a potential fire hazard Never install a screen in or over the exhaust duct This will cause lint to accumulate creating a potential fire hazard Do not assemble ductwork with any fasteners that extend into the duct These fasteners can accumulate lint creating a potential fire hazard Do n...

Страница 6: ...K Stand the dryer upright near the final location and adjust the 4 leveling legs at the corners to ensure that the dryer is level from side to side and front to rear For many applications installing elbows at both the dryer and the wall is highly recommended see illustrations below Elbows allow the dryer to sit close to the wall without kinking and or crushing the transition duct maximizing drying...

Страница 7: ...MUST be vented to the outdoors with the termination securely fastened to the mobile home structure See EXHAUST INFORMATION section 6 The vent MUST NOT be terminated beneath a mobile or manufactured home The vent duct material MUST BE METAL KIT 14 D346 33 MUST be used to attach the dryer securely to the structure The vent MUST NOT be connected to any other duct vent or chimney Do not use sheet meta...

Страница 8: ...elbow as shown above DUCT TAPE CAUTION Use 4 rigid metal ducting only inside the dryer Internal duct joints must be secured with tape otherwise they may sepa rate and cause a safety hazard ADDING COVER PLATE TO REAR OF CABINET Connect standard metal elbows and ducts to complete the exhaust system Cover back opening with a plate Kit WE1M454 available from your local service provider Place dryer in ...

Страница 9: ... Siga todos los códigos y ordenanzas vigentes Nota al instalador Asegúrese de dejar estas instrucciones con el consumidor Nota al consumidor Mantenga estas instrucciones con el Manual de uso y cuidados para referencia futura Antes de que la secadora antigua sea retirada del servicio o elimi nada quítele la puerta La información sobre reparaciones y el diagrama del cableado se en cuentran en la con...

Страница 10: ...anzas locales o si no las hubiera con el CÓDIGO NACIONAL DE GAS ANSI Z223 Esta secadora a gas está equipada con un montaje de válvula y quemador para utilizar sólo con gas natural Mediante el kit de conversión WE25X0217 la organización de atención local puede convertir esta secadora para su uso con gas propano LP TODAS LAS CONVERSIONES DEBEN LLEVARLAS A CABO PERSONAL CAPACITADO Y CALIFICADO EN CUM...

Страница 11: ...exión no deben conectarse directa mente en las roscas de la tubería APLIQUE COMPUESTO PARA TUBERÍA AL ADAPTADOR Y A LA ENTRADA DE GAS DE LA SECADORA Ajuste la tubería flexible de gas utilizando dos llaves ajustables APLIQUE COMPUESTO PARA TUBERÍA EN TODAS LAS ROSCAS MACHO Ajuste todas las conexiones mediante dos llaves ajustables No ajuste de más las conexiones de gas Controle todas las conexiones...

Страница 12: ...ad de codos del sistema de salida dependen del tipo de conducto la cantidad de curvas la clase de campana de salida cubierta de pared y todas las condiciones indicadas a continuación La longitud máxima del conducto para conductos rígidos de metal se indica en la siguiente tabla 4 DIA 4 4 DIA 90 Feet 60 Feet 45 Feet 35 Feet 25 Feet 0 1 2 3 4 LONGITUD DE SALIDA LONGITUD MÁXIMA RECOMENDADA Tipos de c...

Страница 13: ... de una longitud mayor a la especificada en la tabla de longitud de salida Los conductos más largos acumulan pelusa lo que genera un riesgo potencial de incendio Nunca instale un filtro dentro o sobre el conducto de salida Esto provocará la acumulación de pelusas lo que genera un riesgo potencial de incendio No arme la red de conductos con sujeciones que se extiendan dentro del conducto Estas suje...

Страница 14: ...LAR FRENTE A PARTE TRASERA Stand the dryer upright near the final location and adjust the 4 leveling legs at the corners to ensure that the dryer is level from side to side and front to rear Para muchas aplicaciones se recomienda enfáticamente la instalacióndecodosenlasecadorayenlapared verilustraciones de abajo Los codos permiten que la secadora se ubique cerca de la pared sin torcer o aplastar e...

Страница 15: ...norma no sea aplicable con la NORMA NACIONAL ESTADOUNIDENSE PARA CASAS MÓVILES ANSI NFPA Nº 501B La secadora DEBE tener ventilación al exterior con la terminación bien sujeta a la estructura de la casa móvil Ver la INFORMACIÓN SOBRE SALIDA sección 6 La ventilación NO DEBE terminar debajo de una casa móvil o prefabricada El material del conducto de ventilación DEBE SER METAL DEBEutilizarseelKIT14 D...

Страница 16: ...A PRECAUCIÓN Utilice un conducto de metal rígido de 4 sólo dentro de la secadora Las juntas del con ducto interno deben sujetarse con cinta caso contrario pueden separarse y provocar un riesgo de seguridad CÓMO AGREGAR LA PLACA DE CUBIERTA A LA PARTE TRASERA DEL GABINETE Conecte los codos y conductos de metal estándar para completar el sistema de salida Cubra la abertura trasera con la placa Kit W...

Отзывы: