GE GEC-4VDPBC Скачать руководство пользователя страница 4

4 of 11 

P/N 1069686 • REV 1.0 • ISS 10MAR10 

Table 1: Loop Resistance per 1000 feet 

Wire Type 

Resistance 

24 AWG /0,53 mm 

52 ohms 

23 AWG /0,57 mm 

42 ohms 

22 AWG /0,64 mm 

33 ohms 

 

Table 2: Power Distance Chart 

Power Supply Voltage 

12 VDC 

24 VAC 

28 VAC 

Voltage at the Camera 

10.8 VDC 

21.6 VAC 

21.6 VAC 

Dual 24 AWG 

448 ft. / 137 m 

896 ft. / 273 m 

2,388 ft. / 728 m 

100 mA Camera 

Dual 23 AWG 

564 ft. / 172 m  1,130 ft. / 345 m 

3,012 ft. / 918 m 

Dual 24 AWG 

150 ft. / 46

 

m 300 

ft. 

92

 

796 ft. / 243 m 

300 mA Camera 

Dual 23 AWG 

190 ft. / 58 m 

378 ft. / 115 m 

1,004 ft. / 306 m 

Dual 24 AWG 

46 ft. / 14 m 

90 ft. / 28 m 

240 ft. / 73 m 

1 AMP Camera 

Dual 23 AWG 

58 ft. / 18 m 

114 ft. / 35 m 

300 ft. / 92 m 

 

Important Safety Warnings 

•  Installation should be made by a qualified service person and should 

conform to all local codes. 

•  DO NOT bundle UTP signals in the same conduit as high-voltage wiring. 

•  To reduce the risk of fire or electrical shock, do not expose these products to 

rain, moisture, dripping or splashing. 

•  No objects filled with liquids, such as vases, shall be placed on GE equipment.  

•  DO NOT block ventilation openings to let sufficient airflow to the UTP devices. 

•  The Main fuse for models with built-in AC power supply is 5 A at 110 VAC or 

at 3 A 220 VAC. Each camera power fuse is 2 A and can be accessed by 
removing the front panel. Fuses may be replaced by a qualified service 
person only when the unit is off and AC power cord is unplugged. 

•  Use only the power cord and plug supplied with the unit for connecting to AC 

outlets. 

•  Only unplugging the power cord is considered as a main power disconnect. 

Содержание GEC-4VDPBC

Страница 1: ...8PVPDTCHUB and GEC 16PVPDTCHUB come with built in 8 and 16 channel fully isolated class II 24 28 VAC power supplies Each camera power output in addition to an auto reset fuse is equipped with a 2 A g...

Страница 2: ...s been damaged in any way such as a power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not o...

Страница 3: ...vers Passive GE transceivers can transmit video and Up the Coax P T Z control signals up to 750 ft 228 m We recommend using short 18 AWG solid wires for ground connections GE VPD products follow the E...

Страница 4: ...ation should be made by a qualified service person and should conform to all local codes DO NOT bundle UTP signals in the same conduit as high voltage wiring To reduce the risk of fire or electrical s...

Страница 5: ...onnect the Data UTP pigtail Black White of the GE single combiner receiver to the data connector of the camera There is no data connection on GEC VCR Power Connect the power UTP pigtail Black Red of t...

Страница 6: ...eiver unit Video Use provided 2 ft 60 cm coax patch cords to connect the BNC video inputs of video receiving devices such as DVRs or matrix switches Data Connect each RJ 45 data connector to a Cat 5 c...

Страница 7: ...id span location closer to the cameras Use an active receiver hub at control room Step 3 Use a single channel GE combiner transceiver on the camera side considering the camera voltage Diagnostic LEDs...

Страница 8: ...lt Protection 2 A 5x20 mm type T fuse front access plus a 2 5 A self resetting fuse at per channel Main fuse 4 A at 115 VAC 3 A at 220 VAC 5x20 mm GEC 8PVPDTCHUB 7 A at 115 VAC 5 A at 220 VAC 5x20 mm...

Страница 9: ...oncondensing Temperature Operating 10 to 50 C Storage 30 to 70 C Specifications are subject to change without notice Included Accessories Mounting brackets for front rear or wall installations Rubber...

Страница 10: ...1069686 REV 1 0 ISS 10MAR10 Camera side RJ 45 Connections Control Room Data Connections Figure 2 GEC 4VDPBC Cameras 1 4 only 16VDPBC 8PVPDTCHUB 16PVPDTCHUB Cameras 1 8 Figure 3 GEC 16VDPBC 16PVPDTCHUB...

Страница 11: ...owever there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by...