1) Read these instructions.

2) Keep these instructions.

3) Heed all warnings.

4) Follow all instructions.

5) Do not use this apparatus near water.

6) Clean only with a dry cloth.

7) Do not block any ventilation openings.

8) Install in accordance with the manufacturer’s instructions.

9) Do not install near any heat sources such as radiators, heat registers, stoves or other 
apparatus (including DVRs) that produce heat.

10) Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug 
has two blades with one wider than the other. A grounding type plug has two blades and a
third grounding prong. The wider blade or the third prong are provided for your safety. If the 
provided plug does not fit into your outlet, consult an electrician for replacement of the 
obsolete outlet.

11) Protect the power cord from being walked on or pinched particularly at plugs, convenience 
receptacles, and the point where they exit from the apparatus.

12) Only use attachments/accessories specified by the manufacturer.

13) Unplug this apparatus during lightning storms or when unused for long periods of time.

14) Refer all servicing to qualified service personnel. Servicing is required when the apparatus 
has been damaged in any way, such as a power supply cord or plug is damaged, liquid has 
been spilled, or objects have fallen into the apparatus, the apparatus has been exposed to 
rain or moisture, does not operate normally, or has been dropped.

         WARNING! - To reduce the risk of fire or electric shock, do not expose this apparatus to 
rain or moisture. This apparatus shall not be exposed to dripping or splashing and no objects 

filled with liquids, such as vases shall be placed on the apparatus.

       
         WARNING! -  This apparatus is a Class I product. This product must be connected to a 
mains socket outlet with a 

protective earthing connection.

        
          

The mains plug is used as the disconnect device and shall remain readily 

operable.

WARNING! - 

IMPORTANT SAFETY INSTRUCTIONS

DO NOT OPEN

RISK OF ELECTRIC SHOCK

CAUTION

CAUTION: 

TO REDUCE THE RISK OF ELECTRICAL SHOCK,

                   DO NOT REMOVE COVER. NO USER SERVICEABLE
                   PARTS INSIDE. REFER SERVICING TO QUALIFIED
                   SERVICE PERSONNEL.

IMPORTANT SAFETY INSTRUCTIONS

        The exclamation point within an equilateral triangle, is intended to alert the user to the presence of important operating and 
maintenance instructions in the literature accompanying the appliance.

         The lightning flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated 
"dangerous voltage" within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.

 

Содержание GEC-4VDPBC

Страница 1: ...8PVPDTCHUB and GEC 16PVPDTCHUB come with built in 8 and 16 channel fully isolated class II 24 28 VAC power supplies Each camera power output in addition to an auto reset fuse is equipped with a 2 A g...

Страница 2: ...s been damaged in any way such as a power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not o...

Страница 3: ...vers Passive GE transceivers can transmit video and Up the Coax P T Z control signals up to 750 ft 228 m We recommend using short 18 AWG solid wires for ground connections GE VPD products follow the E...

Страница 4: ...ation should be made by a qualified service person and should conform to all local codes DO NOT bundle UTP signals in the same conduit as high voltage wiring To reduce the risk of fire or electrical s...

Страница 5: ...onnect the Data UTP pigtail Black White of the GE single combiner receiver to the data connector of the camera There is no data connection on GEC VCR Power Connect the power UTP pigtail Black Red of t...

Страница 6: ...eiver unit Video Use provided 2 ft 60 cm coax patch cords to connect the BNC video inputs of video receiving devices such as DVRs or matrix switches Data Connect each RJ 45 data connector to a Cat 5 c...

Страница 7: ...id span location closer to the cameras Use an active receiver hub at control room Step 3 Use a single channel GE combiner transceiver on the camera side considering the camera voltage Diagnostic LEDs...

Страница 8: ...lt Protection 2 A 5x20 mm type T fuse front access plus a 2 5 A self resetting fuse at per channel Main fuse 4 A at 115 VAC 3 A at 220 VAC 5x20 mm GEC 8PVPDTCHUB 7 A at 115 VAC 5 A at 220 VAC 5x20 mm...

Страница 9: ...oncondensing Temperature Operating 10 to 50 C Storage 30 to 70 C Specifications are subject to change without notice Included Accessories Mounting brackets for front rear or wall installations Rubber...

Страница 10: ...1069686 REV 1 0 ISS 10MAR10 Camera side RJ 45 Connections Control Room Data Connections Figure 2 GEC 4VDPBC Cameras 1 4 only 16VDPBC 8PVPDTCHUB 16PVPDTCHUB Cameras 1 8 Figure 3 GEC 16VDPBC 16PVPDTCHUB...

Страница 11: ...owever there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by...