4. Dispenser Solenoid Valve (Dispenser Models Only)
1) Disassembling Procedure (Features are model dependent)
2) How to check Dispenser Solenoid Valve
HOW TO CHECK EACH PART
No
No
5
Unscrew and remove Solenoid Valve.
Separate Front PCB connector.
(Features are model dependent.)
3
6
2
Unscrew and remove Cover Ice Flap.
Unscrew to remove Box Dispenser Ice Shut.
1
4
Procedure
Procedure
Disassemble the Cover dispenser Box As
Disconnect 2 terminals and 2P Wire.
( Good ): 215 Ohm (+-10%)
(193 ~ 236 Ohm)
(Defective): Change the part.
( Good ): 96 Ohm (+-8%)
(88 ~ 104 Ohm)
(Defective): Change the part.
Parts
How to Check
Remark
Check the resistance of
both terminals.
Check the resistance of
2 terminals with a Tester.
Flap Heater Assembly
Dispenser Solenoid Valve