1. Freezer Compartment Control
1) Adjust by the pushing the FRZ.SET button.
2) Compressor & Freezer Fan controlled by each mode ON/OFF point.
3) Freezer Compartment ON/OFF Difference : 2C
- MEDIUM OFF point : -19C
- When Room Temperature (RT) is below 13C, Freezer sensor OFF point 2C up ( so, MEDIUM OFF : -17C )
4) Control Temperature Point in Each Mode
6) SUPER FRZ. (QUICK) Mode
- In this mode, Compressor & Freezer Fan motor is on unconditionally for 150min. ( free of freezer sensor )
FUNCTIONS ( TEMPERATURE CONTROL_Dispenser Model )
Initially On
1st Press
2nd Press
3rd Press
4th Press
5th Press
6th Press
Sensor On
-14.8
-15.8
-16.8
-17.8
-11.8
-12.8
-13.8
Sensor Off
-16.8
-17.8
-18.8
-19.8
-13.8
-14.8
-15.8
Sensor On
-12.8
-13.8
-14.8
-15.8
-9.8
-10.8
-11.8
Sensor Off
-14.8
-15.8
-16.8
-17.8
-11.8
-12.8
-13.8
-18
-21
-22
Min
-16
-17
Medium Max
Max
Medium Min
-19
-20
Division
Control
Temperature
Normal
RT <= 13C
Medium
Display
Freezer
Sensor
Freezer
Fan On/Off
SUPER FRZ. Start
( SUPER FRZ. MODE )
NORMAL MODE
Start
150MIN
9
Содержание GCG200NGWC
Страница 1: ...Pub No DWWR1053E GC 200YAWC GC 200YHWC GC 200NGWC GC 200NHWC ...
Страница 3: ...2 External Size Features are model dependent All model has same size SPECIFICATIONS 2 ...
Страница 27: ...1 Basic Model 2 Dispenser Model WIRING DIAGRAM 26 ...
Страница 51: ...COOLING CYCLE HEAVY REPAIR Brzing Reference Drawings 50 ...
Страница 52: ...Water System for Dispenser Model 51 ...