57
08/24/2016
6. Edition, ID No.: 37020GB-F
Operating Manual ERESCO MF4 Type Series
Copyright by GE Sensing & Inspection Technologies GmbH Bogenstrasse 41 D - 22926 Ahrensburg
Fig. 7 - Plug hutch of the digital control unit
ERESCO MF4 control
Fuses at the digital control unit
ERESCO MF4 control
F1
Water cooling pump
Microfuse 4 A/T Ø 5.0 x 20
F2
Power unit 230 V
Microfuse 20 A/FF Ø 6.3 x 32
Plug connections (see Fig. 7):
Pin assignment
X1
~
mains connection
L (1)
N
(2)
PE
Jumper between 3+4 for connecting cable (orange) 230VAC version
Jumper between 3+5 for connecting cable (grey) 115VAC version
Pin assignment X2
of the
potential-free contacts
between
pin 2 and 3:
Prewarning, (42 V / 1.0 A)
between
pin 7 and 8:
High voltage ON, (42 V / 1.0 A)
between
pin 13 and 14
Mains voltage ON, (110VDC, 125VAC, 1A)
Pin assignment X2
of the
door contacts
between
pin 1 and 4:
Door contact 1
between
pin 5 and 6:
Door contact 2
between
pin 9 and 10:
EMERGENCY STOP
between
pin 11 and 12:
EMERGENCY STOP
6
Fuses and pin assignment at ERESCO MF4 control