Machine Compartment Components
Condenser Fan Assembly Removal
1.
Disconnect power to the refrigerator.
2.
Remove the four 1/4 in. hex head screws from
the rear access cover.
3.
Move the water valve out of the way (if
applicable).
4.
Remove the one 1/4 in. hex head screw from the
condenser fan assembly.
5.
Remove the two 1/4 in. hex head screws from
the rear baffle.
6. Unplug the machine compartment connector.
7.
Release the plastic fastener from the baffle
(condenser fan motor wire).
8. Remove the fan blade.
9. Unplug the condenser fan motor connector.
10. Grasp the upper corner of the condenser fan
assembly and move toward the compressor
to allow the assembly to disengage from the
condenser support retainers.