background image

GE imagination at work

GE Healthcare 
P.O. Box 900, FIN-00031 GE, Finland
Tel. +358 10 394 11 

• 

Fax +358 9 146 3310

www.gehealthcare.com

©2006 General Electric Company – All rights reserved.
GE and GE Monogram are trademarks of General Electric Company.

Masimo  and SET are registered trademarks of Masimo Corporation.

Nellcor is a registered trademark of Nellcor Puritan Bennett, Inc.

Dash, TrimKnob, DINAMAP and SuperSTAT are registered  
trademarks of General Electric Company. 

GE Healthcare Oy., doing business as GE Healthcare.

Certification 

   

 

 

UL2601-1 classified 

IEC 60601-1 certified

CE Marking for the 93/42/EEC   UL Classified for CAN/CSA 
Medical Device Directive  

C22.2 No. 601.1

2028034-002-2006.03-V2.0

Storage conditions

Do not exceed
Maximum 

 

70°C (158°F) at 95% relative humidity

Minimum 

 

-40°C (-40°F)

CO

2

 sensor   

-30 to 65°C (-22 to 149°F)

Batteries 

 

-20 to 60°C (-4 to 140°F)

Physical specifications

 

Height 

Depth 

Width 

Weight

*

Dash 5000 

28.7 cm (11.3 in.) 

23.9 cm (9.4 in.) 

30.7 cm (12.2 in.) 

6.4 kg (14 lbs.)

Dash 4000 

27.4 cm (10.8 in.) 

24.3 cm (9.6 in.) 

29.3 cm (11.5 in.) 

5.5 kg (12.2 lbs.)

Dash 3000 

26 cm (10.25 in.) 

20 cm (8 in.) 

28 cm (11.0 in.) 

5.2 kg (11.2 lbs.) 

Operating conditions

Ambient temperature 

0-40°C (32-104°F) (Nellcor 0-35°C (32-95°F))

While charging batteries 

0-35°C (35-95°F)

CO

2

 sensor   

10-40°C (50-104°F)

Relative humidity 

5-95% @40°C

Vibration 

 

MIL-STD 810E, Method 514.4, Category 1

Altitude 

 

-273 m to 2,943 m (-896 to 9,655 ft.)

Warranty

Standard warranty is one year.

* Weight of product without batteries.

Содержание Dash 3000

Страница 1: ... revolutionize patient care and assessment by combining the most complete selection of gold standard patient monitoring parameters with leading edge cardiac technology Enterprise networking Hard wired and wireless network connectivity including access to CIS CVIS PACS RIS HIS and more than 350 beds without central station support contributes to the Dash monitors unprecedented ability to adapt to c...

Страница 2: ...Default and individual Silencing 1 minute current alarm only Pause 5 minutes in Adult ICU mode 3 minutes in Neonatal ICU mode and 5 minute 15 minute or permanent pause in OR mode Volume Default 70 dB measured at 1 meter Invasive blood pressure Number of channels 1 to 4 optional Transducer sites Arterial femoral artery pulmonary arterial central venous right atrial left atrial intracranial and spec...

Страница 3: ... is limited by resolution to 40 Hz 3 dB 25 mm s Specified upper frequency limits may vary by 2 Hz Diagnostic mode 0 67 Hz 0 4 dB to 100 Hz 3 dB For compliance with China 1 0 Hz 0 4dB to 75 Hz 3 dB National Standard Monitoring mode 0 67 0 4 dB to 40 Hz 3 dB Moderate mode 0 67 0 4 dB to 25 Hz 3 dB Maximum mode 5 0 Hz 0 3 dB to 25 Hz 3 dB Noise 30 µV referred to input Pacemaker detection rejection In...

Страница 4: ...jectate temperature and trial number Range Cardiac output 0 2 15 liters per minute Blood temperature 30 42 C Injectate temperature 0 30 C Accuracy Cardiac output 5 Blood temperature 0 2 C Injectate temperature 0 3 C Frequency response dc to 15 Hz 2 Hz Pulse oximetry Parameters monitored Arterial oxygen saturation SpO2 and peripheral pulse rate PPR SpO2 range Nellcor 1 100 Masimo 30 100 GE Ohmeda 3...

Страница 5: ...te 10 110 mmHg Pulse rate as displayed in tabular trends or 3 wave form display Adult 30 200 bpm Pediatric 30 200 bpm Neonate 30 200 bpm Other specifications Overall system accuracy Meets or exceeds SP 10 1992 AAMI standards Automatic cycle times 0 4 hours Tubing length 12 feet adult 8 feet neonatal Automatic cuff deflation Cycle time exceeding 3 minutes 90 seconds neonatal French mode Cycle time ...

Страница 6: ...all specifications 12 of actual from 80 150 BrPM Display resolution 1 mmHg Rise time Less than 200 ms low flow sidestream less than 60 ms mainstream adult reusable or SPU less than 50 ms mainstream infant reusable or SPU Respiration rate accuracy 1 breath min Compensations Automatic barometric pressure 25 mmHg from 530 785 mmHg Operator selectable O2 N2O compensation Calibration Mainstream No rout...

Страница 7: ...ency 2 4 to 2 5 GHz Transmit power 100 mW Data rate 802 11 1Mbps and 2Mbps per channel 802 11b 1 2 5 5 11 Mbps Radio technology Frequency hopping spread spectrum Communication protocol IEEE 802 11 or IEEEE 802 11b UL 1950 Listed ITE 9B97 CE Mark RF Standard US CAN FCC Part 15 Class B RSS 210 Europe ETSI EN 300 328 Japan RCD STD 33R Battery Battery type Exchangeable Lithium Ion Maximum number of ba...

Страница 8: ...dical Device Directive C22 2 No 601 1 2028034 002 2006 03 V2 0 Storage conditions Do not exceed Maximum 70 C 158 F at 95 relative humidity Minimum 40 C 40 F CO2 sensor 30 to 65 C 22 to 149 F Batteries 20 to 60 C 4 to 140 F Physical specifications Height Depth Width Weight Dash 5000 28 7 cm 11 3 in 23 9 cm 9 4 in 30 7 cm 12 2 in 6 4 kg 14 lbs Dash 4000 27 4 cm 10 8 in 24 3 cm 9 6 in 29 3 cm 11 5 in...

Отзывы: