2
CAUTION/ATTENTION
RISK OF INJURY
• While performing installations described, gloves, safety
glasses or goggles should be worn.
RISQUES DE BLESSURE
• Lors de l’exécution des installations décrites, des gants, des lunettes de
sécurité ou des lunettes de protection doivent être portées.
WARNING/AVERTISSEMENT
RISK OF ELECTRIC SHOCK
• Disconnect power at fuse box or circuit breaker before servicing
or installing product.
• Properly ground Tetra
®
power supply.
RISK OF FIRE
• Minimum 10 cm (4”) to side and 2.5 cm (1”) spacing in
compartment surrounding component required.
• Use only approved wire for input/output connection. Minimum
size 18 AWG (0.82 mm
2
).
• Follow all local codes.
• Application considerations potentially requiring additional
spacing include high ambient temperature seen by the
power supply, poor contact with a heat dissipating material,
inadequate ventilation, or direct exposure to sun.
RISQUES DE DÉCHARGES ÉLECTRIQUES
• Coupez l’alimentation électrique à la boîte de fusibles ou au disjoncteur avant
l’entretien ou l’installation du produit.
• Assurez-vous de correctement mettre à terre le bloc d’alimentation Tetra
®
.
RISQUES D’INCENDIE
• Un espacement minimum de 10 cm (4 po) entre 2 alimentations de
puissance est requis ainsi qu’un espacement minimal de 2,5 cm (1 po)
avec toute enceinte.
• N’utilisez que des fils approuvés pour les entrées/sorties de connexion.
Taille minimum 18 AWG (0.82 mm
2
).
• Respectez tous les codes locaux.
• Certaines applications pourraient requérir un espacement additionnel, p.
ex. une température ambiante élevée autour du bloc d’alimentation, un
mauvais contact avec une matière dissipatrice de chaleur, une ventilation
inadéquate ou une exposition directe au soleil.
Save These Instructions
Use only in the manner intended by the manufacturer.
If you have any questions, contact the manufacturer.
Prepare Electrical Wiring
Electrical Requirements
• Acceptable for use in dry, damp and wet locations.
• The grounding and bonding of the LED Driver shall be
done in accordance with National Electric Code (NEC)
Article 600.
• Follow all National Electric Codes (NEC) and local codes.
FOR UL ONLY
Power Supply Installation
Black (-)
Green with
yellow stripe
White (+)
Connect the AC line to the black
(line) and white (neutral) input
wires of the power supply using
18-14 AWG (0.82-2.08 mm
2
)
twist-on wire connectors.
Properly ground (green wire with
yellow stripe) power supply in
accordance with National Electric
Code (NEC) Article 600.
1
Power Supply
Conduit
Power Supply
input wires
AC Line
Run AC line through conduit and
attach conduit to outdoor-rated/
UL approved enclosure. Attach
power supply to enclosure.
Connect the red stripe wire (+)
of the LED strip to the red wire
(+) of the power supply. Connect
the white wire (-) of the LED strip
to the black wire (-) of the power
supply.
2
3
To power supply
Red (+)
Red stripe (+)
White (-)
Black (-)
NOTE:
All electrical connections
should be made within the letter.