2

 CAUTION/ATTENTION

RISK OF INJURY
•  While performing installations described, gloves, safety 

glasses or goggles should be worn.

RISQUES DE BLESSURE
•  Lors de l’exécution des installations décrites, des gants, des lunettes de 

sécurité ou des lunettes de protection doivent être portées.

 WARNING/AVERTISSEMENT

RISK OF ELECTRIC SHOCK

•  Disconnect power at fuse box or circuit breaker before servicing 

or installing product.

•  Properly ground Tetra

®

 power supply.

RISK OF FIRE

•  Minimum 10 cm (4”) to side and 2.5 cm (1”) spacing in 

compartment surrounding component required.

•  Use only approved wire for input/output connection. Minimum 

size 18 AWG (0.82 mm

2

).

•  Follow all local codes.

•  Application considerations potentially requiring additional 

spacing include high ambient temperature seen by the 

power supply, poor contact with a heat dissipating material, 

inadequate ventilation, or direct exposure to sun.

RISQUES DE DÉCHARGES ÉLECTRIQUES

•  Coupez l’alimentation électrique à la boîte de fusibles ou au disjoncteur avant 

l’entretien ou l’installation du produit.

•  Assurez-vous de correctement mettre à terre le bloc d’alimentation Tetra

®

.

RISQUES D’INCENDIE

•  Un espacement minimum de 10 cm (4 po) entre 2 alimentations de 

puissance est requis ainsi qu’un espacement minimal de 2,5 cm (1 po) 

avec toute enceinte.

•  N’utilisez que des fils approuvés pour les entrées/sorties de connexion. 

Taille minimum 18 AWG (0.82 mm

2

).

•  Respectez tous les codes locaux.

•  Certaines applications pourraient requérir un espacement additionnel, p. 

ex. une température ambiante élevée autour du bloc d’alimentation, un 

mauvais contact avec une matière dissipatrice de chaleur, une ventilation 

inadéquate ou une exposition directe au soleil. 

Save These Instructions

Use only in the manner intended by the manufacturer.

If you have any questions, contact the manufacturer.

Prepare Electrical Wiring

Electrical Requirements
•  Acceptable for use in dry, damp and wet locations.
•  The grounding and bonding of the LED Driver shall be 

done in accordance with National Electric Code (NEC) 
Article 600.

•  Follow all National Electric Codes (NEC) and local codes.

FOR UL ONLY

Power Supply Installation

Black (-)

Green with 

yellow stripe

White (+)

Connect the AC line to the black 

(line) and white (neutral) input 

wires of the power supply using 

18-14 AWG (0.82-2.08 mm

2

twist-on wire connectors. 

Properly ground (green wire with 

yellow stripe) power supply in 

accordance with National Electric 

Code (NEC) Article 600. 

1

Power Supply

Conduit

Power Supply 

input wires

AC Line

Run AC line through conduit and 

attach conduit to outdoor-rated/

UL approved enclosure. Attach 

power supply to enclosure.

Connect the red stripe wire (+) 

of the LED strip to the red wire 

(+) of the power supply. Connect 

the white wire (-) of the LED strip 

to the black wire (-) of the power 

supply.

2

3

To power supply 

Red (+)

Red stripe (+)

White (-)

Black (-)

NOTE:

  All electrical connections 

should be made within the letter.

Содержание Current Tetra GEPS12W-60

Страница 1: ... et information de sécurité est disponible à l adresse suivante https products currentbyge com eu HR Hrvatska verzija priručnika za ugradnju i sigurnosnih informacija nalazi se na sljedečoj lokaciji https products currentbyge com eu HU A telepítési útmutató és a biztnosági információk magyar nyelvű változata az alábbi címen található https products currentbyge com eu IT La versione italiana del ma...

Страница 2: ...orties de connexion Taille minimum 18 AWG 0 82 mm2 Respectez tous les codes locaux Certaines applications pourraient requérir un espacement additionnel p ex une température ambiante élevée autour du bloc d alimentation un mauvais contact avec une matière dissipatrice de chaleur une ventilation inadéquate ou une exposition directe au soleil Save These Instructions Use only in the manner intended by...

Страница 3: ...ker or disconnect device for line neutral and ground connections in accordance with National Electric Code NEC Article 600 and all local regulations NOTE Exceeding maximum load per bank will cause the power supply to shut down Once the excess load is removed cycle the input power to restart the power supply NOTE To avoid overloading this power supply with LED modules please refer to the specific m...

Страница 4: ... the Tetra LED System does not exceed the maximum load Ensure the length of supply wire is equal to or below the recommended remote mounting distance Some of the letters are not illuminated Inspect and correct the wires of the non illuminated letters for damage polarity issues If no issues are found see the troubleshooting solution for All letters are OFF Shadows Re route supply wire and secure to...

Отзывы: