3
OPTIONAL
A Weather Box (GEXNWB2) may be used to house
and seal Class 2 connections.
A) Insert wire connectors into weather box. Fill
with electrical grade silicone and close box.
B) Secure the weather box using a #6 or #8 (M2
or M3) screw.
Weather box
can be painted
Light engine
A
B
FOR UL ONLY
NOTE:
For installation in Canada, a disconnect switch of appropriate rating needs to be placed within 29.5 feet
(9 meters) of primary side of the power supply. The switch voltage rating shall not be less than the branch circuit
voltage. The switch must also support twice the amount of input current.
FOR UL ONLY
NOTE:
When installing power supply, connect to the appropriate sized building breaker or disconnect device for line,
neutral and ground connections, in accordance with National Electric Code (NEC) Article 600 and all local regulations.
NOTE:
Exceeding maximum load per bank will cause the power supply to shut down. Once the excess load is
removed, cycle the input power to restart the power supply.
NOTE:
To avoid overloading
this power supply with LED
modules, please refer to the
specific module loading guides.
4
Mount Power Supply in a
horizontal orientation with a
minimum of one screw per
mounting plate (two screws per
power supply) with the base
in contact with the mounting
surface in accordance with
the power supply spacing
requirements described above.
5
Tighten liquid-tight fittings
and properly replace cover
on junction box to ensure a
water-tight seal. If not protected
from the weather, the output
connections may be sealed with
electrical grade silicone.