Programming the Panel
36
Opening Reports (0510)
Reporting-Partition 1 (Default=off)
This setting determines whether or not the panel sends an opening report to
the central station (or pager) after disarming the system.
Note
To use this feature, the Open/Close Reports settings under the
PHONES—CS
PHONE 1-2
and/or
PHONES—PAGER PHONE 1-3
menus must be turned on for the
specific CS Phone or Pager Phone number.
¾
To turn Opening Reports off or on:
1. With the display showing
OPENING REPORTS
OFF/ON
(current setting)
, press
1
(off) or
2
(on). The display flashes the entered setting.
2. Press
ƒ
and the display shows the new set-
ting.
Closing Reports (0511)
Reporting-Partition 1 (Default=off)
This setting determines whether or not the panel sends a closing report to the
central station (or pager) after arming the system.
Note
To use this feature, the Open/Close Reports settings under the
PHONES—CS
PHONE 1-2
and/or
PHONES—PAGER PHONE 1-3
menus must be turned on for the
specific CS Phone or Pager Phone number.
¾
To turn Closing Reports off or on:
1. With the display showing
CLOSING REPORTS
OFF/ON
(current setting)
, press
1
(off) or
2
(on). The display flashes the entered setting.
2. Press
ƒ
and the display shows the new set-
ting.
Recent Closings (0512)
Reporting-Partition 1 (Default=on)
This setting determines whether or not the panel sends a recent closing report
to the central station (or a pager) if an alarm occurs within two minutes
after
the exit delay time expires. Such a report is used to identify a possible exit
fault.
¾
To turn Recent Closings off or on:
1.
With the display showing
RECENT CLOS-
INGS OFF/ON
(current setting)
, press
1
(off)
or
2
(on). The display flashes the entered
setting.
2.
Press
ƒ
and the display shows the new set-
ting.
No Activity (0513)
Reporting-Partition 1 (Default=off)
This setting determines whether or not the panel sends a no activity report to
the central station (or pager) if there is no system activity within a preset time
period (see “” on page 30).
¾
To turn No Activity reports off or on:
1. With the display showing
NO ACTIVITY OFF/
ON
(current setting)
, press
1
(off) or
2
(on).
The display flashes the entered setting.
2. Press
ƒ
and the display shows the new set-
ting.
Duress Option (0514)
Reporting-Partition 1 (Default=off)
This setting determines whether or not the system can be controlled using a
programmed duress code (see “” on page 23).
Because using duress codes often results in false alarms due to code
entry errors, it is strongly recommended not to program any
duress codes.
If a duress code is absolutely necessary, their use with an Interro-
gator is highly recommended to reduce false alarms and accidental
dispatches.
¾
To turn Duress Option off or on:
1. With the display showing
DURESS OFF/ON
(current setting)
, press
1
(off) or
2
(on).
The display flashes the entered setting.
2. Press
ƒ
and display shows the new setting.
Caution
!