background image

210572217 Rev. B 3-08

3.

Changing the Lamp:

 Disconnect power to the unit.

Remove grill by pulling downward on grill and
squeezing grill springs together to release from
housing (

Figure 12)

.

Fluorescent Bulb

: Remove lamp by gently rocking

lamp back and forth while applying outward
pressure to release the lamp from the base.
Replace with Air King model 26WFL or a
compatible CFM26W/GX24q/35 lamp.

Sylvania model: CF26DD/E/835
GE model: F26DBXT4SPX35/4P
Phillips model: PL-C 26W/835/4P/ALTO

Night Light

: Unscrew night light bulb from socket

and replace with a 4 watt maximum type C7
(candelabra base) night light bulb.

Refer to instructions in 

Section 6

 

Finishing the Installation,

to reinstall grill.

5 of 8

Figure 12

www.geelectrical.com

Troubleshooting Guide

Trouble

Probable Cause

Suggested Remedy

1. Fan does not operate when the switch is on.

1a. A fuse may be blown or a circuit tripped.

1a. Replace fuse or reset circuit breaker.

1b. Connector plug from motor is not plugged in.

1b. Turn off power to unit. Remove Grill and plug motor into

receptacle in housing. Restore power to unit.

1c. Wiring is not connected properly.

1c. Turn off power to unit. Check that all wires are connected.

1d. Motor has stopped operating.

1d. Replace motor.

2. Fan is operating, but air moves slower than normal.

2.

Obstruction in the exhaust ducting.

2.

Check for any obstructions in the ducting. The most common
are bird nestsin the roof cap or wall cap where the fan
exhausts to the outside.

3. Fan is operating louder than normal.

3a. Motor is loose.

3a. Turn off power to unit. Remove grill and check that all screws

are fully tightened. Restore power to unit.

3b. Fan blade is hitting housing of unit.

3b. Call your dealer for service.

Содержание BFL80UQ

Страница 1: ... Read all instructions before installing or using exhaust fan 2 Use this unit only in the manner intended by the manufacturer If you have questions contact the manufacturer 3 Before servicing or cleaning the unit switch power off at service panel and lock the service disconnecting means to prevent power from being switched on SAVE THESE INSTRUCTIONS IMPORTANT INSTRUCTIONS OPERATING MANUAL accident...

Страница 2: ... the exhaust fan you should have 1 Grill 1 Damper Assembly attached 4 Mounting Rails 1 26 Watt Fluorescent Lamp 1 Instruction Safety Sheet 2 Choose the location for your fan To ensure the best air and sound performance it is recommended that the length of ducting and the number of elbows be kept to a minimum and that insulated hard ducting be used Larger duct sizes will reduce noise and airflow re...

Страница 3: ...tment cover screw and place the cover in a secure place Figure 7 NOTE If the fan motor plug is connected to the fan housing receptacle unplug so the blower assembly can be completely removed 2 Run wiring from an approved wall switch carrying the appropriate rating One neutral White one ground green or bare copper and three hot Black Purple Yellow leads connected to the switch one for each function...

Страница 4: ...seated in the lamp holder Install a 4 watt maximum type C7 candelabra base night light not included into the side lamp holder Figure 10 4 Installthegrillbysqueezingthetwoendsofthesprings together and installing them up into the slots on the fan s housing Push the grill up into position Figure 11 5 Restore power and test your installation SECTION 7 Use and Care CAUTION MAKE SURE POWER IS SWITCHED O...

Страница 5: ...g Guide Trouble Probable Cause Suggested Remedy 1 Fan does not operate when the switch is on 1a A fuse may be blown or a circuit tripped 1a Replace fuse or reset circuit breaker 1b Connector plug from motor is not plugged in 1b Turn off power to unit Remove Grill and plug motor into receptacle in housing Restore power to unit 1c Wiring is not connected properly 1c Turn off power to unit Check that...

Страница 6: ...llation problem contact your dealer or installer You are responsible for providing adequate electrical exhausting and other connecting facilities See the Installation Instructions provided with this product for electrical exhaust and connection details Replacement of house fuses or resetting of circuit breakers Failure of the product if it is used for something other than the intended purpose of m...

Страница 7: ...crews 5S2202004 18 1 Motor Plate 5S2202005 19 1 Venturi 5S2202006 Qty Description Replacement Part 20 1 Reflector Support Bracket 5S1202036 21 1 Blower Wheel 5S2202003 22 2 Screw 5S2202002 23 1 Motor 5S2202001 24 5 Screw 5S1202037 25 1 26 Watt Lamp Holder 5S1202090 26 1 Light Reflector 5S1202015 27 1 Bushing 5S1202018 28 1 Clip 5S1202017 29 1 Ballast Mounting Bracket 5S1202091 30 2 Screw 5S1202040...

Страница 8: ...210572217 Rev B 3 08 8 of 8 www geelectrical com ...

Отзывы: