background image

210572217 Rev. B 3-08

SECTION 4

Ducting

CAUTION:

 

ALL DUCTING MUST COMPLY WITH

LOCAL AND NATIONAL BUILDING CODES.

1. Connect the ducting to the fan’s duct collar (

Figure

4)

. Secure in place using tape or screw clamp.

Always duct the fan to the outside through a wall or
roof cap.

SECTION 5

Wiring

CAUTION:

 

MAKE SURE POWER IS SWITCHED OFF

AT SERVICE PANEL BEFORE STARTING INSTALLATION.

CAUTION:

 

ALL ELECTRICAL CONNECTIONS MUST

BE MADE IN ACCORDANCE WITH LOCAL CODES,
ORDINANCES, OR NATIONAL ELECTRICAL CODE. IF YOU
ARE UNFAMILIAR WITH METHODS OF INSTALLING
ELECTRICAL WIRING, SECURE THE SERVICES OF A
QUALIFIED ELECTRICIAN.

NOTE:

 This unit includes a side access panel for wiring

that does not require the removal of the fan’s blower
assembly. If you choose to wire the unit from the inside,
you will need to remove the blower assembly and internal
wiring compartment. Both methods are equally effective.

1a.

External Wire Compartment:

 Remove the wire

compartment cover screw and place cover in a
secure place 

(Figure 5)

.

1b.

Internal Wire Compartment:

 Remove the three

screws holding the blower assembly in place and
lift assembly out of housing 

(Figure 6)

. Remove the

wire compartment cover screw and place the cover
in a secure place 

(Figure 7)

.

NOTE:

 If the fan motor plug is connected to the fan

housing receptacle, unplug so the blower assembly can
be completely removed.

2. Run wiring from an approved wall switch carrying

the appropriate rating. One neutral (White), one
ground (green or bare copper), and three hot (Black,
Purple, Yellow leads connected to the switch, one
for each function). Secure the electrical wires to the
housing with an approved electrical connector. Make
sure you leave enough wiring in the box to make the
connection to the fan’s receptacle.

3. From where you have chosen to access the fan’s

junction box, connect the White wire from the house
to the two White wires from the fan. Connect one
Hot (Black) wire from the wall switch to the Black
wire from the fan (this is the fan control). Connect
second Hot (Purple) wire from the wall switch to the
Purple wire from the fan (this is the night light control).
Connect the third Hot (Yellow) wire from the wall
switch to the Yellow wire from the fan (this is the
main light control). Connect the ground wire (green
or bare copper) from the house to the Green wire
from the fan 

(Figure 8)

. Use approved methods for

all connections.

3 of 8

Figure 4

Ducting

Duct
Collar

Figure 5

Screw

Wire
Compartment
Cover

Screw

Wire

Compartment

Cover

Figure 7

www.geelectrical.com

Figure 6

Plug

Screws

Venturi

Содержание BFL80UQ

Страница 1: ... Read all instructions before installing or using exhaust fan 2 Use this unit only in the manner intended by the manufacturer If you have questions contact the manufacturer 3 Before servicing or cleaning the unit switch power off at service panel and lock the service disconnecting means to prevent power from being switched on SAVE THESE INSTRUCTIONS IMPORTANT INSTRUCTIONS OPERATING MANUAL accident...

Страница 2: ... the exhaust fan you should have 1 Grill 1 Damper Assembly attached 4 Mounting Rails 1 26 Watt Fluorescent Lamp 1 Instruction Safety Sheet 2 Choose the location for your fan To ensure the best air and sound performance it is recommended that the length of ducting and the number of elbows be kept to a minimum and that insulated hard ducting be used Larger duct sizes will reduce noise and airflow re...

Страница 3: ...tment cover screw and place the cover in a secure place Figure 7 NOTE If the fan motor plug is connected to the fan housing receptacle unplug so the blower assembly can be completely removed 2 Run wiring from an approved wall switch carrying the appropriate rating One neutral White one ground green or bare copper and three hot Black Purple Yellow leads connected to the switch one for each function...

Страница 4: ...seated in the lamp holder Install a 4 watt maximum type C7 candelabra base night light not included into the side lamp holder Figure 10 4 Installthegrillbysqueezingthetwoendsofthesprings together and installing them up into the slots on the fan s housing Push the grill up into position Figure 11 5 Restore power and test your installation SECTION 7 Use and Care CAUTION MAKE SURE POWER IS SWITCHED O...

Страница 5: ...g Guide Trouble Probable Cause Suggested Remedy 1 Fan does not operate when the switch is on 1a A fuse may be blown or a circuit tripped 1a Replace fuse or reset circuit breaker 1b Connector plug from motor is not plugged in 1b Turn off power to unit Remove Grill and plug motor into receptacle in housing Restore power to unit 1c Wiring is not connected properly 1c Turn off power to unit Check that...

Страница 6: ...llation problem contact your dealer or installer You are responsible for providing adequate electrical exhausting and other connecting facilities See the Installation Instructions provided with this product for electrical exhaust and connection details Replacement of house fuses or resetting of circuit breakers Failure of the product if it is used for something other than the intended purpose of m...

Страница 7: ...crews 5S2202004 18 1 Motor Plate 5S2202005 19 1 Venturi 5S2202006 Qty Description Replacement Part 20 1 Reflector Support Bracket 5S1202036 21 1 Blower Wheel 5S2202003 22 2 Screw 5S2202002 23 1 Motor 5S2202001 24 5 Screw 5S1202037 25 1 26 Watt Lamp Holder 5S1202090 26 1 Light Reflector 5S1202015 27 1 Bushing 5S1202018 28 1 Clip 5S1202017 29 1 Ballast Mounting Bracket 5S1202091 30 2 Screw 5S1202040...

Страница 8: ...210572217 Rev B 3 08 8 of 8 www geelectrical com ...

Отзывы: