210572217 Rev. B 3-08
SECTION 4
Ducting
CAUTION:
ALL DUCTING MUST COMPLY WITH
LOCAL AND NATIONAL BUILDING CODES.
1. Connect the ducting to the fan’s duct collar (
Figure
4)
. Secure in place using tape or screw clamp.
Always duct the fan to the outside through a wall or
roof cap.
SECTION 5
Wiring
CAUTION:
MAKE SURE POWER IS SWITCHED OFF
AT SERVICE PANEL BEFORE STARTING INSTALLATION.
CAUTION:
ALL ELECTRICAL CONNECTIONS MUST
BE MADE IN ACCORDANCE WITH LOCAL CODES,
ORDINANCES, OR NATIONAL ELECTRICAL CODE. IF YOU
ARE UNFAMILIAR WITH METHODS OF INSTALLING
ELECTRICAL WIRING, SECURE THE SERVICES OF A
QUALIFIED ELECTRICIAN.
NOTE:
This unit includes a side access panel for wiring
that does not require the removal of the fan’s blower
assembly. If you choose to wire the unit from the inside,
you will need to remove the blower assembly and internal
wiring compartment. Both methods are equally effective.
1a.
External Wire Compartment:
Remove the wire
compartment cover screw and place cover in a
secure place
(Figure 5)
.
1b.
Internal Wire Compartment:
Remove the three
screws holding the blower assembly in place and
lift assembly out of housing
(Figure 6)
. Remove the
wire compartment cover screw and place the cover
in a secure place
(Figure 7)
.
NOTE:
If the fan motor plug is connected to the fan
housing receptacle, unplug so the blower assembly can
be completely removed.
2. Run wiring from an approved wall switch carrying
the appropriate rating. One neutral (White), one
ground (green or bare copper), and three hot (Black,
Purple, Yellow leads connected to the switch, one
for each function). Secure the electrical wires to the
housing with an approved electrical connector. Make
sure you leave enough wiring in the box to make the
connection to the fan’s receptacle.
3. From where you have chosen to access the fan’s
junction box, connect the White wire from the house
to the two White wires from the fan. Connect one
Hot (Black) wire from the wall switch to the Black
wire from the fan (this is the fan control). Connect
second Hot (Purple) wire from the wall switch to the
Purple wire from the fan (this is the night light control).
Connect the third Hot (Yellow) wire from the wall
switch to the Yellow wire from the fan (this is the
main light control). Connect the ground wire (green
or bare copper) from the house to the Green wire
from the fan
(Figure 8)
. Use approved methods for
all connections.
3 of 8
Figure 4
Ducting
Duct
Collar
Figure 5
Screw
Wire
Compartment
Cover
Screw
Wire
Compartment
Cover
Figure 7
www.geelectrical.com
Figure 6
Plug
Screws
Venturi