GE BFL50UQ Скачать руководство пользователя страница 5

Troubleshooting Guide

Trouble

Probable Cause

Suggested Remedy

1. Fan does not operate when the switch is on.

1a. A fuse may be blown or a circuit tripped.

1a. Replace fuse or reset circuit breaker.

1b. Connector plug from motor is not plugged in.

1b. Turn off power to unit. Remove Grill and plug motor into

receptacle in housing. Restore power to unit.

1c. Wiring is not connected properly.

1c. Turn off power to unit. Check that all wires are connected.

2. Fan is operating, but air moves slower than normal.

2.

Obstruction in the exhaust ducting.

2.

Check for any obstructions in the ducting. The most common

are bird nests in the roof cap or wall cap where the fan
exhausts to the outside.

3. Fan is operating louder than normal.

3a. Motor is loose.

3a. Turn off power to unit. Remove grill and check that all screws

are fully tightened. Restore power to unit.

3b. Fan blade is hitting housing of unit.

3b. Call your dealer for service.

210572123 Rev. D 1-08

5. Restore power and test your installation.

SECTION 7

Use and Care

CAUTION:

 

MAKE SURE POWER IS SWITCHED

OFF AT SERVICE PANEL BEFORE SERVICING THE UNIT.

1.

Cleaning the Grill:

 Remove grill and use a mild

detergent, such as dishwashing liquid, and dry with

a soft cloth. NEVER USE ANY ABRASIVE PADS OR
SCOURING POWDERS. Completely dry grill before
reinstalling. Refer to instructions in 

Section 6

Completing the Installation, to reinstall grill.

2.

Cleaning the Fan Assembly:

 Unplug the motor cord

and light cord from receptacles and loosen the
venturi screw to remove the venturi from the unit.
Wipe all parts with a dry cloth or gently vacuum the
fan. NEVER IMMERSE ELECTRICAL PARTS IN
WATER. Refer to instructions in 

Section 6

 

Completing

the Installation, to reinstall venturi.

CAUTION:

 

ALLOW BULB TO COOL BEFORE

REPLACING.

3.

Changing the Light Bulb:

 Disconnect power to the

unit. Remove the light lens by squeezing at the tabs
and pulling down (

Figure 13)

. Remove light bulb and

refer to instructions in 

Section 6

 

Completing the

Installation, to complete the light bulb change and
installation of light lens.

5 of 8

Figure 12

www.geelectrical.com

Содержание BFL50UQ

Страница 1: ...ng the following 1 Read all instructions before installing or using exhaust fan 2 Use this unit only in the manner intended by the manufacturer If you have questions contact the manufacturer 3 Before servicing or cleaning the unit switch power off at service panel and lock the service disconnecting means to prevent power from being switched on SAVE THESE INSTRUCTIONS IMPORTANT INSTRUCTIONS OPERATI...

Страница 2: ...dition to the exhaust fan you should have 1 Grill with Light Lens 4 Mounting Rails 1 Damper Assembly attached 1 Instruction Safety Sheet 2 Remove the fan s venturi assembly which is secured in place with one screw through the venturi Figure 1 This is a captive screw and will stay installed in venturi Keep the venturi assembly and the grill in the carton until needed so they do not get damaged or l...

Страница 3: ...finished ceiling Secure with four nails not provided to ensure proper installation Figure 4 SECTION 4 Ducting CAUTION ALL DUCTING MUST COMPLY WITH LOCAL AND NATIONAL BUILDING CODES 1 Connect the ducting to the fan s duct collar Figure 7 Secure in place using tape or screw clamp Always duct the fan to the outside through a wall or roof cap NOTE If damper detaches from unit reattach by snapping the ...

Страница 4: ...pproved methods for all connections SECTION 6 Completing the Installation 1 Reinstallthefan sventuribyholdingitatapproximately a 45 degree angle hook the two tabs on the venturi into the slots on the housing and secure in place by tightening the venturi screw Rotate the blower wheel by hand to ensure it spins freely Now plug the fan motor into the receptacle Figure 10 2 Install the grill lens ligh...

Страница 5: ...08 5 Restore power and test your installation SECTION 7 Use and Care CAUTION MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE SERVICING THE UNIT 1 Cleaning the Grill Remove grill and use a mild detergent such as dishwashing liquid and dry with a soft cloth NEVER USE ANY ABRASIVE PADS OR SCOURING POWDERS Completely dry grill before reinstalling Refer to instructions in Section 6 Completing t...

Страница 6: ...llation problem contact your dealer or installer You are responsible for providing adequate electrical exhausting and other connecting facilities See the Installation Instructions provided with this product for electrical exhaust and connection details Replacement of house fuses or resetting of circuit breakers Failure of the product if it is used for something other than the intended purpose of m...

Страница 7: ... Motor Clip 5S5201001 11 1 10 Lock Washer 5S1999007 12 1 10 Acorn Nut 5S1999008 13 1 Motor 50 CFM 5S2201001 1 Motor 70 CFM 5S2201003 1 14 2 3 5 6 7 8 9 10 11 12 13 15 16 Qty Description Replacement Part 14 2 Hex Nut 5S1999006 15 1 Impeller 5S1299001 16 1 Motor Plate 5S1201014 17 1 Captive Screw 5S1999005 18 1 Scroll 5S1201006 19 1 14 ga Ground Wire 5S1999003 20 1 10 Ground Screw 5S1999002 21 2 Pal...

Страница 8: ...210572123 Rev D 1 08 8 of 8 www geelectrical com ...