background image

WARRANTY

WHAT IS COVERED?

Full Five Year Parts Warranty from date of original proof of
purchase. We will provide, free of charge, a replacement part
that fails due to manufacturing defect in material or workmanship,
when installed and used as directed in the User’s Guide.

This warranty is extended to the original purchaser for products
purchased for ordinary home use.

GE Bath Fan Hot Line

1-800-684-9975

FOR TECHNICAL ASSISTANCE

AND / OR QUESTIONS.

Read your User’s Guide.

 

If you have any questions about operating the product, please contact your dealer.

Some states and provinces do not allow the exclusion or limitation of incidental or consequential damages and some states
do not allow limitations on how long an implied warranty lasts, so these exclusions or limitations may not apply to you. This
warranty gives you specific legal rights and you may have other rights which vary from state to state and province to province.

WHAT IS NOT COVERED?

• Installation services or service trips to your home to teach

you how to use the product.

• Labor costs or the cost of replacement components as part

of routine maintenance.

• Failure or defects in product arising from Improper installation

If you have an installation problem, contact your dealer or
installer. You are responsible for providing adequate
electrical, exhausting and other connecting facilities. See
the Installation Instructions provided with this product for
electrical, exhaust and connection details.

• Replacement of house fuses or resetting of circuit breakers.

• Failure of the product if it is used for something other than

the intended purpose of manufacturer or used commercially.

• Damage to the product caused by accident, fire, floods,

acts of customer, or acts of God.

This warranty contains the sole and exclusive warranty of GE for claims based on defects in these products. Upon the expiration
of the warranty period, all such liability shall terminate. There are no other warranties, whether written, oral, implied or
statutory. NO IMPLIED STATUTORY WARRANTY OF MERCHANTABILITY OR FITNESS FOR PARTICULAR PURPOSE SHALL APPLY.

IN NO EVENT SHALL GE BE LIABLE FOR ANY SPECIAL, CONSEQUENTIAL, INDIRECT, OR INCIDENTAL DAMAGES, SUCH AS, BUT
NOT LIMITED TO, LOSS OF PROFIT OR REVENUES, LOSS OF USE OF THE PRODUCTS OR ANY ASSOCIATED EQUIPMENT, DAMAGE
TO ASSOCIATED EQUIPMENT, OR COST OF SUBSTITUTE PRODUCTS.

IN NO EVENT, SHALL GE’S LIABILITY TO BUYER FROM THE SALE OF THESE PRODUCTS EXCEED THE PRICE OF THE DEFECTIVE
PRODUCT SOLD AND ANY SUCH LIABILITY SHALL TERMINATE UPON THE EXPIRATION OF THE WARRANTY PERIOD.

210572123 Rev. D 1-08

6 of 8

www.geelectrical.com

Содержание BFL50UQ

Страница 1: ...ng the following 1 Read all instructions before installing or using exhaust fan 2 Use this unit only in the manner intended by the manufacturer If you have questions contact the manufacturer 3 Before servicing or cleaning the unit switch power off at service panel and lock the service disconnecting means to prevent power from being switched on SAVE THESE INSTRUCTIONS IMPORTANT INSTRUCTIONS OPERATI...

Страница 2: ...dition to the exhaust fan you should have 1 Grill with Light Lens 4 Mounting Rails 1 Damper Assembly attached 1 Instruction Safety Sheet 2 Remove the fan s venturi assembly which is secured in place with one screw through the venturi Figure 1 This is a captive screw and will stay installed in venturi Keep the venturi assembly and the grill in the carton until needed so they do not get damaged or l...

Страница 3: ...finished ceiling Secure with four nails not provided to ensure proper installation Figure 4 SECTION 4 Ducting CAUTION ALL DUCTING MUST COMPLY WITH LOCAL AND NATIONAL BUILDING CODES 1 Connect the ducting to the fan s duct collar Figure 7 Secure in place using tape or screw clamp Always duct the fan to the outside through a wall or roof cap NOTE If damper detaches from unit reattach by snapping the ...

Страница 4: ...pproved methods for all connections SECTION 6 Completing the Installation 1 Reinstallthefan sventuribyholdingitatapproximately a 45 degree angle hook the two tabs on the venturi into the slots on the housing and secure in place by tightening the venturi screw Rotate the blower wheel by hand to ensure it spins freely Now plug the fan motor into the receptacle Figure 10 2 Install the grill lens ligh...

Страница 5: ...08 5 Restore power and test your installation SECTION 7 Use and Care CAUTION MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE SERVICING THE UNIT 1 Cleaning the Grill Remove grill and use a mild detergent such as dishwashing liquid and dry with a soft cloth NEVER USE ANY ABRASIVE PADS OR SCOURING POWDERS Completely dry grill before reinstalling Refer to instructions in Section 6 Completing t...

Страница 6: ...llation problem contact your dealer or installer You are responsible for providing adequate electrical exhausting and other connecting facilities See the Installation Instructions provided with this product for electrical exhaust and connection details Replacement of house fuses or resetting of circuit breakers Failure of the product if it is used for something other than the intended purpose of m...

Страница 7: ... Motor Clip 5S5201001 11 1 10 Lock Washer 5S1999007 12 1 10 Acorn Nut 5S1999008 13 1 Motor 50 CFM 5S2201001 1 Motor 70 CFM 5S2201003 1 14 2 3 5 6 7 8 9 10 11 12 13 15 16 Qty Description Replacement Part 14 2 Hex Nut 5S1999006 15 1 Impeller 5S1299001 16 1 Motor Plate 5S1201014 17 1 Captive Screw 5S1999005 18 1 Scroll 5S1201006 19 1 14 ga Ground Wire 5S1999003 20 1 10 Ground Screw 5S1999002 21 2 Pal...

Страница 8: ...210572123 Rev D 1 08 8 of 8 www geelectrical com ...

Отзывы: