Safety Instructions

 . . . . . . . . . . .2

Operating Instructions

Controls—Dip Switches  . . . . . . . . .3–5
Controls—Terminal 
Connections  . . . . . . . . . . . . . . . . . . .6, 7
On/Off Switch  . . . . . . . . . . . . . . . . . . . .8
Ventilation Control . . . . . . . . . . . . . . . .8

Care and Cleaning

Air Filters  . . . . . . . . . . . . . . . . . . . . . . . . .9
Base Pan . . . . . . . . . . . . . . . . . . . . . . . . .9
Exhaust Coils  . . . . . . . . . . . . . . . . . . . . .9

Installation Instructions

Electrical Supply  . . . . . . . . . . . . .11–13
Installing the Zoneline  . . . . . . .14–21
Preparation  . . . . . . . . . . . . . . . . . . . . .10
Servicing . . . . . . . . . . . . . . . . . . . . . . . .22

Troubleshooting Tips

 . . . . . . .23

Normal Operating Sounds  . . . . . . .24

Consumer Support

Consumer Support  . . . . . .Back Cover
Warranty  . . . . . . . . . . . . . . . . . . . . . . .27

Cool Only, Heat/Cool and 

Heat Pump Models 

7500 Series

Owner’s Manual and

Installation Instructions

ge.com

Write the model and serial 
numbers here:

Model # __________________

Serial # __________________

Find these numbers on a label
on the front case panel.

Zoneline

®

V

e

rtical

Printed in China

Содержание AZ75H09DAC

Страница 1: ...s Electrical Supply 11 13 Installing the Zoneline 14 21 Preparation 10 Servicing 22 Troubleshooting Tips 23 Normal Operating Sounds 24 Consumer Support Consumer Support Back Cover Warranty 27 Cool Only Heat Cool and Heat Pump Models 7500 Series Owner s Manual and Installation Instructions ge com Write the model and serial numbers here Model __________________ Serial __________________ Find these n...

Страница 2: ...om the manufacturer and not repaired Do not use a cord that shows cracks or abrasion damage along its length or at either the plug or connector end Product must be operated with the electrical plug supplied with the product Do not replace the electrical plug supplied with the product If the receptacle does not match the plug the receptacle must be changed out by a qualified electrician Unplug or d...

Страница 3: ...esent NOTE The owner is responsible for setting the appropriate dip switches and connecting terminals Controls Dip Switches Dip Switches All Electric Heat Heat pump models only When this switch is enabled UP heat pump operation is locked out causing the unit to provide only electric resistance heat ALL I2 R All Electric Heat ALL I2 R All Electric Heat Heat pump models only FREEZ S Freeze Sentinel ...

Страница 4: ... the fan to run continuously Occupancy Sensor When this switch is enabled UP it allows the unit to utilize an infrared motion sensor and a door switch for occupancy detection This feature allows an energy management system to be installed and operated in conjunction with the unit FREEZE S Freeze Sentinel CONST FAN Constant ON Fan OCCUPIED Occupancy Sensor Duct The duct select function allows the i...

Страница 5: ...elect the cooling limits The next three switches are used to control the heating limits Temperature limiting during COOL mode all temperatures shown in F UP DOWN Minimum Maximum NONE 1 2 3 60 85 1 2 3 64 85 1 2 3 66 85 2 1 3 68 85 2 3 1 70 85 1 2 3 NONE 72 85 1 3 2 74 85 3 1 2 76 85 Temperature limiting during HEAT mode all temperatures shown in F UP DOWN Minimum Maximum NONE 4 5 6 60 85 4 5 6 60 ...

Страница 6: ...N Improper CDCwiring may damage the Zoneline electronics or cause erratic Zoneline operation No common busing is permitted A separate wire pair must be run from each separate controlling switch to each individual Zoneline Room Air Sensor Requires room air sensor kit RAVRMS When connected the room air sensor will allow utilization of the temperature limiting and freeze sentinel features NOTE If GE ...

Страница 7: ...n the room is opened or closed This feature must be used in conjunction with the motion sensor The door and motion sensors work together to automatically cycle the unit between normal and energy management operations Central Desk Control When connected the unit lock out is released and it can be turned ONor OFF with a switch located at the Central Desk Control A separate wire pair must be run from...

Страница 8: ... Pumps on some models Heat pumps can reduce operating costs by exchanging heat from the outside air even when the outside temperature is below freezing and releasing that heat indoors To get the best economic benefit from your heat pump don t change the room thermostat setting very often Raising the heat setting 2 3 degrees will cause the Zoneline to use its electric heating elements in order to r...

Страница 9: ...ter at least every 30 days Air Filters The most important thing you can do to maintain the Zoneline is to change the filter at least every 30 days Dirty filters reduce cooling heating and air flow Changing the filter will Decrease cost of operation save energy prevent clogged heat exchanger coils and reduce the risk of premature component failure CAUTION Do not operate the Zoneline without the fil...

Страница 10: ...ician Follow the National Electrical Code NEC and or local codes and ordinances For personal safety this Zoneline unit and case must be properly grounded Protective devices fuses or circuit breakers acceptable for Zoneline installations are specified on the nameplate of each unit Do not use an extension cord with this unit Aluminum building wiring may present special problems consult a qualified e...

Страница 11: ...rdance with the NEC and local codes ordinances and regulations Power supply kit Recommended branch circuit wire sizes Nameplate maximum circuit AWG Wire breaker size size 15A 14 20A 12 30A 10 AWG American Wire Gauge Single circuit breaker from main box Based on copper wire single insulated conductor at 60 C NOTE Use copper conductors only FOR 230 208 VOLT POWER CORD CONNECTIONS ONLY 1 Remove the f...

Страница 12: ...CTION CHART on page 13 to select the appropriate kit It is the responsibility of the installer to ensure the connection of components is done in accordance with electrical codes Direct connection to branch circuit wiring inside the provided junction box must be made by connecting as follows in steps 1 3 below ATTACH CONDUIT Use the round knockout hole at the top of the junction box to install cond...

Страница 13: ...0 240 VAC When connecting the Zoneline to a single phase circuit for 230V applications Connect the white and black leads of the Zoneline power supply kit to the branch circuit L1 and L2 leads The white lead of the power supply kit should be identified by the installer using electrical tape with some color other than green or white Connect the green lead of the power supply kit to the power supply ...

Страница 14: ... 12 D x 193 4 W x 32 H RAVWP15 15 D x 193 4 W x 32 H Cutout Dimensions 20 W x 321 4 H Access Panel with Return Air Grille RAVRG1 Return Air Grille RAVRG2 Cutout Dimensions 28 W x 48 H Cutout Dimensions 203 8 W x 203 8 H OR Wall Thermostat Model Type Mechanical Thermostat Electronic Thermostat Heat Cool Models 4 wire 5 wire Heat Pump Models 6 wire 6 wire Check the thermostat instructions for correc...

Страница 15: ...ir grille Filter bracket Secure platform to the floor Platform 231 4 x 231 4 square Min load capacity 175 lbs 4 min from front of case Unit installed through FRONT of case 5 min from front of case Unit installed through SIDE of case 3 min from two sides of case Plenum cutout 321 4 H x 20 W Drain fittings 3 4 Outside wall Platform Wall plenum Field supplied outer flashing 10 111 2 A B A Minimum rec...

Страница 16: ...depth 231 8 D Case height 31 E Condensate drains 3 4 connector Primary Drain Centerline of cutout is approximately 51 4 from left case wall and 81 2 from back case wall Secondary Drain Centerline of cutout is approximately 61 2 from left case wall and 51 4 from back case wall F Typical wall plug 6 12 above case G Room air sensor kit 10 long Outside wall Flex duct may be used for transitions only U...

Страница 17: ... the option that best suits your installation requirements Follow the Installation Instructions provided with the return air grille accessory for installation details NOTE Use only one filter in the installation The filter may be installed on the unit or in the access panel door Unit mounted filter with a field supplied return air grille and access door panel RAVRG2 Return air grille RAVRG1 Access...

Страница 18: ...WP8 8 D x 193 4 W x 32 H RAVWP12 12 D x 193 4 W x 32 H RAVWP15 15 D x 193 4 W x 32 H 2 Make drain hole cutout s Primary Drain Centerline of drain is approximately 51 4 from left platform edge and 81 2 from back platform edge Secondary Drain Centerline of drain is approximately 61 2 from left platform edge and 51 4 from back platform edge 3 Place the platform in the utility closet with the followin...

Страница 19: ...can collapse and cause airflow restrictions Do not use flex duct for 90 bends or unsupported runs of 5 ft or more 3 Installation Instructions Your airflow should be balanced based on many factors such as available ESP room CFM and ductwork Consult an HVAC engineer for proper applications External static pressure ESP can be measured with a manometer or pitot tube Once this ESP is established you ca...

Страница 20: ... may be removed to enable the unit to be slid into the case 2 Ground the unit to the case by installing the front case to unit hex bolt and or case to unit side screw 5a Hex bolt Air discharge outlet Rigid ductwork Inside wall 20 Primary female drain fitting 3 4 Leveling legs INSTALL AND GROUND THE UNIT TO THE CASE UNIT INSTALLED THROUGH SIDE OF CASE 1 Slide the side of the unit into the case Push...

Страница 21: ...ctions as appropriate of this manual for proper connections 3 Replace the case front panel by replacing the four front screws and the two top screws 6 Installation Instructions Thermostat Unit Connections 21 Maximum Wiring Length for Thermostat Connection to the Unit 66 ft for AWG 18 60 ft for AWG 20 40 ft for AWG 24 AWG American Wire Gauge CONNECT THE TOP DUCT 1 Install the duct onto the air disc...

Страница 22: ...r case top duct adjusting screws counterclockwise 3 Remove the front case panel 4 Remove the front and or side case to unit grounding screw if present 5 Slide the unit out of the case 22 FINAL CHECK Review this Checklist before restoring power Correct line voltage Single circuit only HVACR type breaker fuse Ductwork connected Case and unit level Wall plenum caulked Level Flashing Drain connected W...

Страница 23: ... minimum of 65 free area Non GE grilles may be too restrictive for proper performance Consult your salesperson for assistance The air filter is dirty Change the filter at least every 30 days See the Care and Cleaning Air Filters section The room may have When the Zoneline is first turned on you need to been hot or cold allow time for the room to cool down or warm up Outdoor air is Set the vent con...

Страница 24: ...nel is set at fan cycle up This will cause the fan to cycle on and off with the compressor You may also hear a fan noise stop and start You may notice a few minutes delay in starting if you try to restart the Zoneline too soon after turning it off or if you adjust the thermostat right after the compressor has shut off This is due to a built in restart protector for the compressor that causes a 3 m...

Страница 25: ...Safety Instructions Operating Instructions Care and Cleaning Troubleshooting Tips Consumer Support Notes ge com 25 ...

Страница 26: ...Notes Consumer Support Troubleshooting Tips Care and Cleaning Operating Instructions Safety Instructions 26 ...

Страница 27: ...roduct resulting from modifications to the product or due to unreasonable use including failure to provide reasonable and necessary maintenance Failure or damage resulting from corrosion due to installation in a coastal environment except for models treated with special factory applied anti corrosion protection as designated in the model number Damage to product caused by improper power supply vol...

Страница 28: ...ut our Website today For the hearing impaired please call 800 TDD GEAC 800 833 4322 Parts and Accessories ge com Individuals qualified to service their own appliances can have parts or accessories sent directly to their homes VISA MasterCard and Discover cards are accepted Order on line today 24 hours every day or by phone at 800 626 2002 during normal business hours Instructions contained in this...

Страница 29: ...ion du climatiseur Zoneline 14 21 Préparation 10 Réparation 22 Dépannage 23 Bruits normaux de fonctionnement 24 Service à la clientèle Garantie 27 Service à la clientèle Dernière page Modèles à climatisation seulement à chauffage climatisation et thermopompe Série 7500 Manuel d utilisation et directives d installation Inscrivez ci dessous les numéros de modèle et de série N de modèle _____________...

Страница 30: ... est endommagée Le produit doit être utilisé avec la fiche électrique fournie avec l appareil Ne remplacez pas la fiche électrique fournie avec le produit Si la prise de courant ne convient pas à la fiche électrique il faut faire remplacer cette prise par un électricien qualifié Avant d effectuer une réparation débranchez l appareil ou coupez l alimentation électrique en enlevant le fusible ou en ...

Страница 31: ...rder les bornes de la façon appropriée Commandes Commutateurs DIP Commutateurs DIP Chauffage électrique thermopompe seulement Lorsque ce commutateur est réglé au niveau haut UP le fonctionnement de la thermopompe est bloqué le chauffage étant assuré uniquement par l élément chauffant ALL I2R Chauffage électrique All I2R Chauffage électrique Thermopompe seulement FREEZ S Protection antigel Sentinel...

Страница 32: ...continuellement Détecteur d occupation Lorsque ce commutateur est au niveau haut UP il permet à l appareil d utiliser un détecteur de mouvement à infrarouge et un détecteur d ouverture de porte pour détecter la présence d occupants Cette fonction permet d installer et de faire fonctionner un système de gestion de l énergie conjointement avec l appareil FREEZE S Protection antigel Sentinel CONST FA...

Страница 33: ...de chauffage Limitation de la température au mode CLIMATISATION températures en C F HAUT UP BAS DOWN Minimum Maximum AUCUN 1 2 3 15 5 60 29 4 85 1 2 3 17 7 64 29 4 85 1 2 3 18 8 66 29 4 85 2 1 3 20 0 68 29 4 85 2 3 1 21 1 70 29 4 85 1 2 3 AUCUN 22 2 72 29 4 85 1 3 2 23 3 74 29 4 85 3 1 2 24 4 76 29 4 85 LimitationdelatempératureaumodeCHAUFFAGE températuresen C F HAUT UP BAS DOWN Minimum Maximum AU...

Страница 34: ...rovoquer un mauvais fonctionnement de ce dernier Il est interdit d utiliser une barre omnibus Il faut acheminer deux fils distincts à partir de chaque interrupteur de commande vers chacun des appareils Zoneline Capteur d air ambiant exige l ensemble de capteur RAVRMS Lorsqu il est raccordé le capteur d air ambiant permet l utilisation des fonctions de limitation de la température et de protection ...

Страница 35: ...et le détecteur d ouverture de porte travaillent ensemble pour faire fonctionner automatiquement de façon cyclique l appareil entre le mode de fonctionnement normal et le mode de gestion de l énergie Poste de commande central Lorsque cette fonction est raccordée l appareil est déverrouillé et peut être MIS EN MARCHE ou ARRÊTÉ au moyen d un interrupteur du poste de commande central Il faut achemine...

Страница 36: ...érieur est inférieure au point de congélation puis en libérant cette chaleur à l intérieur Pour tirer le maximum de votre thermopompe sur le plan économique ne modifiez pas très souvent le réglage du thermostat mural Lorsque vous augmentez le réglage de 2 ou 3 degrés pour le chauffage l appareil Zoneline utilise ses éléments chauffants électriques pour atteindre rapidement la nouvelle température ...

Страница 37: ...èrement les serpentins de sortie de l appareil Zoneline S ils sont obstrués par de la poussière ou de la suie ils peuvent être nettoyés à la vapeur de façon professionnelle par votre Centre de service après vente GE Pour ce faire il vous faudra sortir l appareil de son boîtier pour inspecter les serpentins car l accumulation de saleté se produit du côté sortie 9 Entretien et nettoyage Avant de le ...

Страница 38: ...é et ou les ordonnances et codes locaux Pour votre sécurité le boîtier et l appareil Zoneline doivent être correctement mis à la terre Les dispositifs de protection acceptables fusibles ou disjoncteurs pour l installation d un appareil Zoneline sont indiqués sur la plaque signalétique de chaque appareil N utilisez pas de rallonge électrique avec cet appareil Le câblage en aluminium de l immeuble p...

Страница 39: ... règlements locaux en vigueur Ensemble d alimentation électrique Grosseur de fil recommandée pour un circuit de dérivation Capacité maximale du disjoncteur Grosseur de fil indiquée sur la plaque AWG signalétique 15A 14 20A 12 30A 10 AWG American Wire Gauge Disjoncteur simple du panneau de distribution principal Établie à partir d un conducteur isolé simple en cuivre à 60 C REMARQUE N utilisez que ...

Страница 40: ...nsemble approprié reportez vous au TABLEAU DE RACCORDEMENT ÉLECTRIQUE à la page 13 L installateur a la responsabilité de s assurer que le raccordement des composants est conforme à tous les codes d électricité Pour effectuer le branchement direct aux fils du circuit de dérivation à l intérieur de la boîte de jonction fournie il faut suivre les trois étapes ci dessous INSTALLATION DU CONDUIT Utilis...

Страница 41: ...ement de l appareil Zoneline à un circuit monophasé de 230 V Raccordez les fils blanc et noir de l ensemble d alimentation électrique de l appareil Zoneline aux fils L1 et L2 du circuit de dérivation L installateur doit identifier le fil blanc de l ensemble d alimentation électrique à l aide de ruban gommé de n importe quelle couleur sauf vert ou blanc Raccordez le fil vert de l ensemble d aliment...

Страница 42: ... 1 cm L x 81 2 cm 15 po x 193 4 po x 32 po Dimensions de l ouverture 50 8 cm L x 81 9 cm H 20 po x 321 4 po Panneau d accès avec grille de retour d air RAVRG1 Grille de retour d air RAVRG2 Dimensions de l ouverture 51 7 cm L x 51 7 cm H 203 8 po x 203 8 po Dimensions de l ouverture 71 1 cm L x 121 9 cm H 28 po x 48 po OU Thermostat mural Modèle Thermostat mécanique Electronic Thermostat Chauffage ...

Страница 43: ... 7 cm 5 po min à partir de l avant du boîtier appareil installé par le CÔTÉ du boîtier 7 6 cm 3 po min à partir des deux côtés du boîtier Ouverture pour la gaine de 81 9 cm H x 50 8 cm L 32 1 4 po x 20 po Mur extérieur Plateforme Gaine murale Solin acheté localement A B A Largeur minimum recommandée pour la porte d accès 76 2 cm 30 po B Hauteur minimum recommandée pour la porte d accès 127 0 cm 50...

Страница 44: ...lement principal la ligne centrale de l ouverture se trouve à environ 13 3 cm 51 4 po de la paroi gauche du boîtier et à 21 5 cm 81 2 po de la paroi arrière du boîtier Raccord d écoulement secondaire la ligne centrale de l ouverture se trouve à environ 16 5 cm 61 2 po de la paroi gauche du boîtier et à 13 3 cm 51 4 po de la paroi arrière du boîtier F Prise de courant murale entre 15 2 et 30 4 cm e...

Страница 45: ...d air intérieure Choisissez l option qui convient le mieux à votre installation Suivez les directives données avec la grille de retour d air pour l installation REMARQUE N utilisez qu un seul filtre dans l installation Le filtre peut être installé sur l appareil ou dans la porte ou le panneau d accès Filtre monté sur l appareil avec grille de retour d air achetée localement et porte panneau d accè...

Страница 46: ...x 32 po 2 Pratiquez des ouvertures pour le système d écoulement Raccord d écoulement principal la ligne centrale du raccord d écoulement se trouve à environ 13 3 cm 51 4 po de la paroi gauche du boîtier et à 21 5 cm 81 2 po de la paroi arrière du boîtier Raccord d écoulement secondaire la ligne centrale du raccord d écoulement se trouve à environ 16 5 cm 61 2 po de la paroi gauche du boîtier et à ...

Страница 47: ...circulation d air dans la pièce et le bruit causé par le conduit tandis qu un débit plus faible a tendance à accroître la capacité latente et à réduire le bruit Vue de côté Mur intérieur Raccord d écoulement femelle de 1 9 cm 3 4 po Tuyau en PVC Coude de 90 Tuyau en PVC conduite d écoulement externe Tuyau en PVC conduite d écoulement interne Vue de côté Mur intérieur Raccord d écoulement femelle d...

Страница 48: ...re par l entremise du boîtier en installant à l avant un boulon à tête hexagonale et ou une vis sur le côté pour relier l appareil au boîtier 5a Boulon à tête hexagonale Sortie d air Conduit rigide Mur intérieur 20 Raccord d écoulement principal femelle de 1 9 cm 3 4 po Pieds de nivellement INSTALLATION ET MISE À LA TERRE DE L APPAREIL DANS LE BOÎTIER APPAREIL INSTALLÉ PAR LE CÔTÉ DU BOÎTIER 1 Fai...

Страница 49: ...dements appropriés 3 Remettez en place le panneau avant en réinstallant les quatre vis à l avant et les deux vis sur le dessus de l appareil 6 Directives d installation Thermostat Raccordements de l appareil 21 Longueur maximum des fils pour raccorder le thermostat à l appareil 20 1 m 66 pi pour des fils n 18 AWG 18 2 m 60 pi pour des fils n 20 AWG 12 2 m 40 pi pour des fils n 24 AWG AWG American ...

Страница 50: ...neau avant 4 Enlevez la vis de mise à la terre à l avant et ou sur le côté de l appareil 5 Tirez sur l appareil pour le sortir de son boîtier 22 DERNIÈRES VÉRIFICATIONS Passez en revue la liste de contrôle qui suit avant de rétablir l alimentation électrique Tension de secteur correcte Circuit simple seulement Fusible disjoncteur pour chauffage ventilation et climatisation Conduit raccordé Boîtier...

Страница 51: ... peuvent être trop restrictives pour assurer un rendement approprié Consultez votre vendeur si vous avez besoin d aide Le filtre à air est sale Remplacez le filtre au moins tous les 30 jours Reportez vous à la section Entretien et nettoyage Filtres à air La température dans la pièce Lorsque vous mettez en marche l appareil Zoneline pour était peut être basse ou élevée la première fois il faut atte...

Страница 52: ...e met en marche et s arrête de façon cyclique en même temps que le compresseur Il est possible que vous entendiez aussi le bruit du ventilateur lorsqu il se met en marche et s arrête Lorsque vous tentez de remettre en marche l appareil Zoneline trop rapidement après l avoir éteint ou lorsque vous réglez le thermostat immédiatement après l arrêt du compresseur vous remarquerez peut être un délai de...

Страница 53: ...Consignes de sécurité Fonctionnement Entretien et nettoyage Dépannage Service à la clientèle 25 Notes ...

Страница 54: ...Notes 26 Service à la clientèle Dépannage Entretien et nettoyage Fonctionnement Consignes de sécurité ...

Страница 55: ...sibles ou le réenclenchement des disjoncteurs Les filtres Les défaillances du produit attribuables à des modifications apportées au produit ou à une utilisation déraisonnable y compris les défaillances imputables à un entretien inadéquat ou négligent Les défaillances ou les dommages attribuables à la corrosion en raison d une installation dans un environnement côtier sauf dans le cas des modèles a...

Страница 56: ...quate peut affecter le fonctionnement sécuritaire de l appareil Les consommateurs au Canada peuvent commander des pièces et des accessoires en ligne par téléphone à la firme Gordon Williams Corp au 1 888 209 0999 pendant les heures de bureau Contactez nous Si vous n êtes pas satisfait du service après vente dont vous avez bénéficié Premièrement communiquez avec les gens qui ont réparé votre appare...

Отзывы: