This installation manual is designed to guide the installer
through the process of installing and starting conditioners
featuring the AvantaPure
series controllers.
This manual is a reference and will not include every
system installation situation. The person installing this
equipment should have:
•
Training in the AvantaPure series controllers and
Autotrol brand valves
•
Knowledge of water conditioning and how to
determine proper control settings
•
Basic plumbing skills
•
The directional instructions "left" and “right" are
determined by looking at the front of the unit.
Figure 1
Icons That Appear In This Manual
WARNING:
Failure to follow this
instruction can result in personal injury or
damage to the equipment.
Note:
This will make the process easier if followed.
Introduction
Inspect the unit for damage or missing parts. Contact your
supplier if any discrepancies exist.
Parts Included
•
Resin Tank with Valve
•
Brine Tank with Cover
•
Power Transformer
•
Water Bypass
•
Hose Adapter and Flow Control in a bag
•
Brine Well Assembly
General Warnings and Safety
Information
Electrical
There are no user-serviceable parts in the AC adapter,
motor, or controller. In the event of a failure, these should
be replaced.
•
All electrical connections must be completed
according to local codes.
•
Use only the power AC adapter that is supplied.
•
The power outlet must be grounded.
•
To disconnect power, unplug the AC adapter from its
power source.
Mechanical
•
Do not use petroleum based lubricants such as
vaseline, oils, or hydrocarbon based lubricants. Use
only 100% silicone lubricants.
•
All plastic connections should be hand tightened.
Teflon tape may be used on connections that do not
use an O-ring seal.
Do not use pliers or pipe
wrenches.
•
All plumbing must be completed according to local
codes.
•
Soldering near the drain line should be done before
connecting the drain line to the valve. Excessive heat
will cause interior damage to the valve.
•
Observe drain line requirements.
•
Do not use lead-based solder for sweat solder
connections.
•
The drain line must be a minimum of 1/2-inch
diameter. Use 3/4-inch pipe if the backwash flow rate
is greater than 7 GPM (26.5 Lpm) or the pipe length is
greater than 20 feet (6 m).
•
Do not support the weight of the system on the
control valve fittings, plumbing, or the bypass.
•
It is not recommended to use sealants on the threads.
Use Teflon
a
tape on the threads of the 1-inch NPT
elbow, the drain line connections, and other NPT
threads.
•
Install appropriate grounding strap across the inlet
and outlet metal piping of the water conditioning
system to ensure that a proper ground is maintained.
WARNING:
Dry location use only, unless
used with a Listed Class 2 Power Supply
suitable for outdoor use.