5
Ensure cable is
secured by spring
clips at each end of
the light fixture.
Option A Installation Steps
1a
3
2
4
Loop one end of cable around a structural
member and secure with a stop sleeve.
Secure upper end of support cables to a structural
member at intervals of approximately 16 ft. Secure
lower end to horizontal cable. See
Installation
Overview
diagram above for reference.
Loosen the turnbuckle and secure it to a structural
member. Secure opposite end of cable to turnbuckle.
Tighten turnbuckle to reduce slack in cable.
Hang light engines on horizontal cable and position them evenly along cable.
Connect light engines to drivers directly or by using inter-connection cables (see next section for details).
Stop sleeve
Structural member
Attach turnbuckle and tighten
Structural
member
Horizontal
cable
1b
Loop one end of cable around a structural
member and secure with a wire clamp.
Wire Clamp
Structural member
Inter-connection cable to driver
ATTENTION / ATTENTION
• Installer is responsible for suspension cable assembly.
• Test cable with at least 5x luminaires weight.
• L’installateur est responsable de l’assemblage du câble de
suspension.
• Tester le câble avec au moins 5 fois le poids des luminaires.