Thermal Expansion

Determine if a check valve exists in the inlet water line. Check with your local water
utility.

It may have been installed in the cold water line as a separate back flow preventer, or it

may be part of a pressure reducing valve, water meter or water softener. A check valve located in
the cold water inlet line can cause what is referred to as a 

“closed water system”

. A cold

water inlet line with no check valve or back flow prevention device is referred to as an 

“open”

water system.

As water is heated, it expands in volume and creates an increase in the pressure within the water
system. This action is referred to as 

“thermal expansion”

. In an 

“open”

water system,

expanding water which exceeds the capacity of the water heater flows back into the city main
where the pressure is easily dissipated.

“closed water system”

, however, prevents the expanding water from flowing back into the

main supply line, and the result of 

“thermal expansion”

can create a rapid and dangerous

pressure increase in the water heater and system piping. This rapid pressure increase can quickly
reach the safety setting of the relief valve, causing it to operate during each heating cycle.
Thermal expansion, and the resulting rapid, and repeated expansion and contraction of
components in the water heater and piping system can cause premature failure of the relief 
valve, and possibly the heater itself. Replacing the relief valve 

will not

correct the problem!

The suggested method of controlling thermal expansion is to install an expansion tank in the cold
water line between the water heater and the check valve (see illustration below). The expansion
tank is designed with an air cushion built in that compresses as the system pressure increases,
thereby relieving the over pressure condition and eliminating the repeated operation of the relief
valve. Other methods of controlling thermal expansion are also available. Contact your installing
contractor, water supplier or plumbing inspector for additional information regarding this subject.

Combustion Air
Inlet Openings

Water Supply Connections

Refer to the illustration below for suggested typical installation. The installation of unions or
flexible copper connectors is recommended on the hot and cold water connections so that the
water heater may be easily disconnected for servicing if necessary. The HOT and COLD water
connections are clearly marked and are 3/4” NPT on all models. Install a shut-off valve in the cold
water line near the water heater.

IMPORTANT: Do not apply
heat to the HOT or COLD
water connections. If sweat
connections are used,
sweat tubing to adapter
before fitting adapter to 
the cold water connections
on heater. Any heat applied
to the cold water supply
fittings will permanently
damage the dip tube.

Typical Installation

Heat trap 
6” minimum

Heat trap 

6” minimum

Union

Hot water outlet

to fixtures

Temperature and

pressure relief valve

Relief valve
discharge line to
suitable open drain.

To gas supply

Cap

Jacket door

Auxiliary catch pan

Ground joint union

To cold water
supply

6” air gap

Draft hood

Pitch up 1/4”
per foot

Union

Thermostatic gas valve

Anode

Vent connector

to chimney

Manual gas shut-off

Shut-off valve

Thermal expansion
tank (if required)

Sediment trap

Shut-
off
valve

Drain Pan Pipe to

suitable drain

NOTICE: The National Fuel
Gas Code (NFGC)
mandates a manual gas
shut-off valve: See (NFGC)
for complete instructions.
Local codes or plumbing
authority requirements may
vary from the instructions
or diagrams provided and
take precedent over these
instructions.

Vacuum Relief Valve

(Not Supplied)

If required, install per local codes

and valve manufacturer’s

instructions.

Содержание AP13204-4

Страница 1: ...ition System The purpose of this manual is twofold one to provide the installer with basic directions and recommendations for the proper installation and adjustment of the water heater and two for the...

Страница 2: ...te is needed to obtain service under the warranty IMPORTANT Fill out and return the Consumer Product Registration Card that is in the back of this manual If you do need service you can relax knowing h...

Страница 3: ...ate air supply for proper operation Be sure to inspect the vent system for proper installation at initial start up and at least annually thereafter Refer to the Care and Cleaning section of this manua...

Страница 4: ...re Dial DANGER Hotter water increases the Potential for Hot Water SCALDS D A N G E R HOT Water temperature over 125 F can cause severe burns instantly or death from scalds Children disabled and elderl...

Страница 5: ...federal state and or local laws rules regulations or customs LP gas must be used with great caution It is heavier than air and will collect first in lower areas making it hard to detect at nose level...

Страница 6: ...a qualified technician SAFETY PRECAUTIONS IMPORTANT SAFETY INFORMATION READ ALL INSTRUCTIONS BEFORE USING WARNING For your safety the information in this manual must be followed to minimize the risk o...

Страница 7: ...not allow the water heater to ignite until examined by a Qualified Service Technician The water heater must be located so it is not subject to physical damage for example by moving vehicles area flood...

Страница 8: ...directly or through vertical ducts there must be two openings located as specified above and each must have a minimum net free area of not less than one square inch per 4000 Btuh of the total input r...

Страница 9: ...nk is designed with an air cushion built in that compresses as the system pressure increases thereby relieving the over pressure condition and eliminating the repeated operation of the relief valve Ot...

Страница 10: ...lve and discharge line The end of the discharge line should not be threaded or concealed and should be protected from freezing No valve of any type restriction or reducer coupling should be installed...

Страница 11: ...than 3 8 psi 10 5 w c for natural gas or 1 2 psi 14 w c for LP gas Gas Supply The branch gas supply line to the water heater should be clean 1 2 black steel pipe or other approved gas piping material...

Страница 12: ...Blankets Insulation blankets available to the general public for external use on gas water heaters are not necessary The purpose of an insulation blanket is to reduce the standby heat loss encountered...

Страница 13: ...the venting system complies with the guidelines found in the Use and Care Manual and National Fuel Gas Code DO contact a Qualified service technician if the pilot or main burner will not stay lit The...

Страница 14: ...nt room to service heater Combustible materials such as clothing cleaning materials rags etc clear of the base of the heater Clearances from combustion air inlet openings observed see page 7 Gas Suppl...

Страница 15: ...c chemicals such as those used for boiler treatment into this system Tee fitting for horizontal hot water supply lines Hot water supply to house From HOT outlet on water heater From HOT outlet on wate...

Страница 16: ...heater be sure to read and follow the instructions on the label pictured below and all other labels on the water heater as well as the warnings printed in this manual Failure to do so can result in u...

Страница 17: ...ps to accumulate near water heater Do Not store or use gasoline or other flammable vapors and liquids such as adhesives or paint thinner in vicinity of this or any other appliance If such flammables m...

Страница 18: ...ken The hottest temperature water will be at the top of the tank closest to the outlet pipe delivering hot water to the home Stacking can cause this top layer of water to be hotter than the water towa...

Страница 19: ...rs of dependable trouble free service It is recommended that a periodic inspection of the gas control thermostat burner relief valve internal flue way and venting system should be made by service pers...

Страница 20: ...g shut down period the water heater s operation and controls should be checked by qualified service personnel Make certain the water heater is completely filled again before placing it in operation NO...

Страница 21: ...ed by a clogged qualified service technician Gas Cock Knob not See the Lighting The Water Heater section of this correctly positioned manual Pilot does not stay Loose thermocouple The connection at th...

Страница 22: ...essary relight using the instructions in the Lighting The Water Heater section of this manual The gas control thermostat See the Water Temperature Setting of The Water may be set too low Heater sectio...

Страница 23: ...Safety Instructions Installation Instructions Operating Instructions Care and Cleaning Troubleshooting Tips Customer Service 23 Notes...

Страница 24: ...Customer Service Troubleshooting Tips Care and Cleaning Operating Instructions Installation Instructions Safety Instructions 24 Notes...

Страница 25: ...Tube The kit provides extra speed clips and tamper resistant screws Not supplied with all models Burner Assembly Kit Heat Trap Nipple Heat Trap Nipple Replacement parts For 30 40 and 50 gallon models...

Страница 26: ...Manufacturer s National Service Department at the following address 2600 Gunter Park Drive Montgomery AL 36109 1413 When contacting the manufacturer the following information will be requested Model a...

Страница 27: ...Rheem Manufacturing Company Warranty Registration Department P O Box 34070 Louisville KY 40232 4070 Please place in envelope and mail to Cut here Cut here 27...

Страница 28: ...rs Miss Street Address City State Date Placed In Use Month Day Year Zip Code Apt Last Name Phone Number _ _ Complete and mail this Consumer Product Ownership Registration today After mailing the regis...

Отзывы: