background image

Problem

Possible Causes

What To Do

Condensation

This usually happens when  

This is normal. After the water in the tank warms 

a new water heater is 

up the condensation will disappear. If, however, the 

filled for the first time. 

condition persists, examine the piping and fittings 
for possible leaks.

Moisture from the products

This is normal and will disappear in time. Excessive 

of combustion condensing 

condensation can cause pilot outage.

on the tank surface.

An undersized water 

Use a water heater size that meets the requirements 

heater will cause 

of your needs.

condensation. 

Yellow flame 

Scale on top of the burner.

Call a qualified service technician to remove scale.

or soot

Flue or combustion air inlet 

Remove obstruction or debris from flue or 

openings are restricted. 

combustion air inlet openings on jacket. 

Not enough combustion or

Proper operation of the water heater requires air for 

ventilation air supplied to

combustion and ventilation. See the Combustion and

the water heater location.

Ventilation Air information in the “Installing The Water 
Heater” section of this manual.

Unable to light

Air in gas line.

Contact a qualified service technician to purge the air

the pilot

from the gas line.

Pilot orifice clogged.

The pilot should be cleaned or replaced by a qualified 
service technician.

Pilot tube pinched or 

The pilot should be cleaned, repaired or replaced by a 

clogged.

qualified service technician.

Gas Cock Knob not

See the “Lighting The Water Heater” section of this 

correctly positioned.

manual. 

Pilot does not stay 

Loose thermocouple.

The connection at the gas control (thermostat) should 

lit when the RED

be tightened by a qualified service technician.

button is released

Thermocouple defective.

The thermocouple should be replaced by a qualified 
service technician.

Safety magnet defective.

The gas control (thermostat) should be replaced by a 
qualified service technician.

Gas control (thermostat)’s

The gas control (thermostat) should be replaced by a  

single use gas shut-off 

qualified service technician.

device has opened.

Combustion Shutoff Device

The combustion shutoff device should be replaced  

Tripped.

by a qualified service technician

CAUTION:

For your safety DO NOT attempt repair of gas piping, gas control (gas control (thermostat)),

burners, vent connectors or other safety devices. Refer repairs to qualified service personnel.

!

Troubleshooting Tips

Save time and money! Review the charts on the following 
pages first and you may not need to call for service. 

This water heater incorporates a combustion shut off device that shuts the operation of the water heater
down if undesirable combustion conditions occur. Such as the presence of flammable vapors or blockage of
the combustion air inlet openings. Please contact a Qualified Service Technician if this occurs.

Safety Instructions

Installation Instructions

Operating Instructions

Care and Cleaning

T

roubleshooting Tips

Customer Service

21

Before you call for service…

Содержание AP13204-4

Страница 1: ...ition System The purpose of this manual is twofold one to provide the installer with basic directions and recommendations for the proper installation and adjustment of the water heater and two for the...

Страница 2: ...te is needed to obtain service under the warranty IMPORTANT Fill out and return the Consumer Product Registration Card that is in the back of this manual If you do need service you can relax knowing h...

Страница 3: ...ate air supply for proper operation Be sure to inspect the vent system for proper installation at initial start up and at least annually thereafter Refer to the Care and Cleaning section of this manua...

Страница 4: ...re Dial DANGER Hotter water increases the Potential for Hot Water SCALDS D A N G E R HOT Water temperature over 125 F can cause severe burns instantly or death from scalds Children disabled and elderl...

Страница 5: ...federal state and or local laws rules regulations or customs LP gas must be used with great caution It is heavier than air and will collect first in lower areas making it hard to detect at nose level...

Страница 6: ...a qualified technician SAFETY PRECAUTIONS IMPORTANT SAFETY INFORMATION READ ALL INSTRUCTIONS BEFORE USING WARNING For your safety the information in this manual must be followed to minimize the risk o...

Страница 7: ...not allow the water heater to ignite until examined by a Qualified Service Technician The water heater must be located so it is not subject to physical damage for example by moving vehicles area flood...

Страница 8: ...directly or through vertical ducts there must be two openings located as specified above and each must have a minimum net free area of not less than one square inch per 4000 Btuh of the total input r...

Страница 9: ...nk is designed with an air cushion built in that compresses as the system pressure increases thereby relieving the over pressure condition and eliminating the repeated operation of the relief valve Ot...

Страница 10: ...lve and discharge line The end of the discharge line should not be threaded or concealed and should be protected from freezing No valve of any type restriction or reducer coupling should be installed...

Страница 11: ...than 3 8 psi 10 5 w c for natural gas or 1 2 psi 14 w c for LP gas Gas Supply The branch gas supply line to the water heater should be clean 1 2 black steel pipe or other approved gas piping material...

Страница 12: ...Blankets Insulation blankets available to the general public for external use on gas water heaters are not necessary The purpose of an insulation blanket is to reduce the standby heat loss encountered...

Страница 13: ...the venting system complies with the guidelines found in the Use and Care Manual and National Fuel Gas Code DO contact a Qualified service technician if the pilot or main burner will not stay lit The...

Страница 14: ...nt room to service heater Combustible materials such as clothing cleaning materials rags etc clear of the base of the heater Clearances from combustion air inlet openings observed see page 7 Gas Suppl...

Страница 15: ...c chemicals such as those used for boiler treatment into this system Tee fitting for horizontal hot water supply lines Hot water supply to house From HOT outlet on water heater From HOT outlet on wate...

Страница 16: ...heater be sure to read and follow the instructions on the label pictured below and all other labels on the water heater as well as the warnings printed in this manual Failure to do so can result in u...

Страница 17: ...ps to accumulate near water heater Do Not store or use gasoline or other flammable vapors and liquids such as adhesives or paint thinner in vicinity of this or any other appliance If such flammables m...

Страница 18: ...ken The hottest temperature water will be at the top of the tank closest to the outlet pipe delivering hot water to the home Stacking can cause this top layer of water to be hotter than the water towa...

Страница 19: ...rs of dependable trouble free service It is recommended that a periodic inspection of the gas control thermostat burner relief valve internal flue way and venting system should be made by service pers...

Страница 20: ...g shut down period the water heater s operation and controls should be checked by qualified service personnel Make certain the water heater is completely filled again before placing it in operation NO...

Страница 21: ...ed by a clogged qualified service technician Gas Cock Knob not See the Lighting The Water Heater section of this correctly positioned manual Pilot does not stay Loose thermocouple The connection at th...

Страница 22: ...essary relight using the instructions in the Lighting The Water Heater section of this manual The gas control thermostat See the Water Temperature Setting of The Water may be set too low Heater sectio...

Страница 23: ...Safety Instructions Installation Instructions Operating Instructions Care and Cleaning Troubleshooting Tips Customer Service 23 Notes...

Страница 24: ...Customer Service Troubleshooting Tips Care and Cleaning Operating Instructions Installation Instructions Safety Instructions 24 Notes...

Страница 25: ...Tube The kit provides extra speed clips and tamper resistant screws Not supplied with all models Burner Assembly Kit Heat Trap Nipple Heat Trap Nipple Replacement parts For 30 40 and 50 gallon models...

Страница 26: ...Manufacturer s National Service Department at the following address 2600 Gunter Park Drive Montgomery AL 36109 1413 When contacting the manufacturer the following information will be requested Model a...

Страница 27: ...Rheem Manufacturing Company Warranty Registration Department P O Box 34070 Louisville KY 40232 4070 Please place in envelope and mail to Cut here Cut here 27...

Страница 28: ...rs Miss Street Address City State Date Placed In Use Month Day Year Zip Code Apt Last Name Phone Number _ _ Complete and mail this Consumer Product Ownership Registration today After mailing the regis...

Отзывы: