8

Installing the water heater.

CAUTION: The presence of water in the piping and water heater does not provide sufficient conduction for a

ground. Non-metallic piping, dielectric unions, flexible connectors etc. can cause the water heater to be electrically
isolated.

Customer Service

T

roubleshooting Tips

Care and Cleaning

Operating Instructions

Installation Instructions

Safety Instructions

Branch Circuit Sizing and Wire Size Guide

Total Water

Recommended Over Current Protection 

Copper Wire Size AWG Based 

Heater Wattage

(fuse or circuit breaker amperage rating)

on N.E.C. Table 310-16 (75°C)

120V

208V

240V

120V

208V

240V

1500*

20

15

15

12

14

14

1700

20

15

15

12

14

14

2000

25

15

15

10

14

14

2500

30

15

15

10

14

14

3000

35

20

20

8

12

12

3500

25

20

10

12

3800

25

20

10

12

4000

25

25

10

10

4500

30

25

10

10

5000

30

30

10

10

5500

35

30

8

10

6000

40

35

8

8

9000

50

8

*Less than 1500 watts may be wired 14 gauge with 15 amp protection. Check Local Electrical Codes, as they will also apply.

Electrical Connections

A separate branch circuit with copper
conductors, overcurrent protective device
and suitable disconnecting means must
be provided by a qualified electrician. 
All wiring must conform to local codes
or latest edition of National Electrical
Code ANSI/NFPA 70.
The water heater is completely wired to
the junction box inside jacket at the top
front of the water heater. An opening for
1/2

or 3/4

electrical fitting is provided

for field wiring connections.
The voltage requirements and wattage load
for the water heater are specified on the
rating plate on the front of the water heater. 

The branch circuit wiring should
include either:

Metallic conduit or metallic sheathed
cable approved for use as a grounding
conductor and installed with
fittings approved for the purpose.
Non-metallic sheathed cable, metallic
conduit or metallic sheathed cable
not approved for use as a ground
conductor shall include a separate
conductor for grounding. It should
be attached to the ground terminals
of the water heater and the electrical
distribution box.

WARNING

WARNIN

G

Water heater junction box.

NOTICE: This guide
recommends minimum
branch circuit sizing and
wire size based on National
Electric Code. Refer to
wiring diagrams in this
manual for field wiring
connections.

Ground screw

Junction 

box

cover

Wire connections

Conduit

connector

Condensation

Condensation can form on the tank 
when it is first filled with water.
Condensation might also occur with 
a heavy water draw and very cold inlet
water temperatures. 

This condition is not unusual, and will
disappear after the water becomes
heated. If, however, the condensation
continues, examine the piping and fittings
for possible leaks.

Additional information on this subject
may be found at 

www.rheem.com

under “Library,” scroll down to the
Technical Service Bulletins 1400 Series
Section and choose Bulletin #1402.

Содержание AP12170-4

Страница 1: ...carefully so that they may understand how to perform these operations Do not destroy this manual Please read carefully and keep in a safe place for future reference Recognize this symbol as an indicat...

Страница 2: ...ip or cancelled check here Proof of the original purchase date is needed to obtain service under the warranty IMPORTANT Fill out and return the Consumer Product Registration Card that is in the back o...

Страница 3: ...e Operating Instructions in this manual for detailed instructions in how to adjust the thermostat s DANGER Hotter water increases the Potential for Hot Water SCALDS D A N G E R HOT Water temperature o...

Страница 4: ...rom Office of the State Architect 400 P Street Sacramento CA 95814 or you may call 916 324 5315 or ask a water heater dealer However applicable local codes shall govern installation For residential wa...

Страница 5: ...d to permit inspection and servicing such as removal of elements or checking controls The water heater and water lines should be protected from freezing temperatures Do not install the water heater in...

Страница 6: ...ld water inlet line can cause what is referred to as a closed water system A cold water inlet line with no check valve or back flow prevention device is referred to as an open water system As water is...

Страница 7: ...of the relief valve and discharge line The end of the discharge line should not be threaded or concealed and should be protected from freezing No valve of any type restriction or reducer coupling shou...

Страница 8: ...jacket at the top front of the water heater An opening for 1 2 or 3 4 electrical fitting is provided for field wiring connections The voltage requirements and wattage load for the water heater are spe...

Страница 9: ...ternal insulation blanket to this water heater pay careful attention to the following so as not to restrict the proper function and operation of the water heater Do not cover the temperature and press...

Страница 10: ...opening of the T P Valve R E L I E F V A L V E COLD HOT Typical top connection arrangement Typical side connection arrangement Relief Valve Insulation Installation CAUTION Ensure the T P Valve openin...

Страница 11: ...Provisions made to protect area from water damage Sufficient room to service heater Water Supply Water heater completely filled with water Air purged from water heater and piping Water connections tig...

Страница 12: ...h as air escaping through the pipe as the water begins to flow Do not smoke or use an open flame near the faucet at the time it is open CAUTION The cause of the high temperature condition must be inve...

Страница 13: ...n be regulated by setting the temperature dial of the adjustable surface mounted thermostat s located behind the jacket access panel s Dual element heaters have two thermostats Safety and energy conse...

Страница 14: ...shorten the life of the glass lined tank and will exclude warranty coverage Care and cleaning of the water heater Draining the Water Heater CAUTION Shut off power to the water heater before draining w...

Страница 15: ...connect switch if used are in the ON position The thermostat may See the Temperature regulation of the water heater be set set too low section of this manual Leaking or open hot Make sure all faucets...

Страница 16: ...T attempt repair of electrical wiring thermostat s heating elements or other operating controls Refer repairs to qualified service personnel Relief valve Junction box cover Anode rod Hot outlet heat t...

Страница 17: ...til it breaks away from the remainder of the cavity insert See illustration to the left Discard the crossbar It cannot and need not be replaced Replace the thermostat and or element as necessary Repla...

Страница 18: ...X 4 L2 RED 1 3 2 UPPER THERMOSTAT HIGH TEMP LIMIT ECO UPPER HEATING ELEMENT BLUE YELLOW BLACK L1 G BRANCH CIRCUIT TO ELECTRICAL DISTRIBUTION PANEL 240 V JUNCTION BOX 4 L2 RED 1 3 1 2 BLACK RED BLACK L...

Страница 19: ...19 Rheem Manufacturing Company Warranty Registration Department P O Box 34070 Louisville KY 40232 4070 Please place in envelope and mail to Cut here Cut here...

Страница 20: ...Mr Ms Mrs Miss Street Address City State Date Placed In Use Month Day Year Zip Code Apt Last Name Phone Number _ _ Complete and mail this Consumer Product Ownership Registration today After mailing th...

Отзывы: