GE AP12170-4 Скачать руководство пользователя страница 3

Safety Instructions

Installation Instructions

Operating Instructions

Care and Cleaning

T

roubleshooting Tips

Customer Service

Time/Temperature Relationship in Scalds

Water Temperature

Time To Produce a Serious Burn

120°F

More than 5 minutes

125°F

1

1

/

2

to 2 minutes

130°F

About 30 seconds

135°F

About 10 seconds

140°F

Less than 5 seconds

145°F

Less than 3 seconds

150°F

About 1

1

/

2

seconds

155°F

About 1 second

Table courtesy of Shriners Burn Institute

The chart shown above may be used as a guide 
in determining the proper water temperature for
your home.

NOTICE: Households with small children, disabled, 
or elderly persons may require a 120°F or lower
thermostat setting to prevent contact with “HOT”
water.

The temperature of the water in the heater is
regulated by the adjustable surface mounted
thermostat(s) located behind the jacket access
panel(s). Dual element heaters have two
thermostats. To comply with safety regulations
the thermostat(s) were set at 120°F before the
water heater was shipped from the factory.

The illustration at the left
shows the temperature
adjustment dial used
for setting the water
temperature. 

Refer to the Operating
Instructions in this
manual for detailed
instructions in how to
adjust the thermostat(s).

DANGER:

Hotter water increases the Potential 

for Hot Water SCALDS.

!

D A N G E R

!

HOT

Water temperature over 125

°

F can

cause severe burns instantly or
death from scalds.

Children, disabled and elderly are
at highest risk of being scalded.

See instruction manual before
setting temperature at water
heater.

Feel water before bathing or
showering.

Temperature limiting valves are
available, see manual.

BURN

R

E

S

E

T

R

E

S

E

T

TURN OFF

POWER

BEFORE

SERVICING

90

°

F

150

°

F

125

°

F

IMPORTANT SAFETY INFORMATION.

READ ALL INSTRUCTIONS BEFORE USING.

3

Reset button

Thermostat

protective

cover

Thermostat
dial pointer

WARNING!

WATER TEMPERATURE ADJUSTMENT

Safety and energy conservation are factors to be considered when selecting the water
temperature setting of water heater’s thermostat. Water temperatures above 125°F can
cause severe burns or death from scalding. Be sure to read and follow the warnings outlined
on the label pictured below. This label is also located on the water heater near the
thermostat access panel.

NOTICE:  Mixing valves are available for reducing point of
use water temperature by mixing hot and cold water in
branch water lines are available. Contact a licensed
plumber or the local plumbing authority for further
information.

Содержание AP12170-4

Страница 1: ...carefully so that they may understand how to perform these operations Do not destroy this manual Please read carefully and keep in a safe place for future reference Recognize this symbol as an indicat...

Страница 2: ...ip or cancelled check here Proof of the original purchase date is needed to obtain service under the warranty IMPORTANT Fill out and return the Consumer Product Registration Card that is in the back o...

Страница 3: ...e Operating Instructions in this manual for detailed instructions in how to adjust the thermostat s DANGER Hotter water increases the Potential for Hot Water SCALDS D A N G E R HOT Water temperature o...

Страница 4: ...rom Office of the State Architect 400 P Street Sacramento CA 95814 or you may call 916 324 5315 or ask a water heater dealer However applicable local codes shall govern installation For residential wa...

Страница 5: ...d to permit inspection and servicing such as removal of elements or checking controls The water heater and water lines should be protected from freezing temperatures Do not install the water heater in...

Страница 6: ...ld water inlet line can cause what is referred to as a closed water system A cold water inlet line with no check valve or back flow prevention device is referred to as an open water system As water is...

Страница 7: ...of the relief valve and discharge line The end of the discharge line should not be threaded or concealed and should be protected from freezing No valve of any type restriction or reducer coupling shou...

Страница 8: ...jacket at the top front of the water heater An opening for 1 2 or 3 4 electrical fitting is provided for field wiring connections The voltage requirements and wattage load for the water heater are spe...

Страница 9: ...ternal insulation blanket to this water heater pay careful attention to the following so as not to restrict the proper function and operation of the water heater Do not cover the temperature and press...

Страница 10: ...opening of the T P Valve R E L I E F V A L V E COLD HOT Typical top connection arrangement Typical side connection arrangement Relief Valve Insulation Installation CAUTION Ensure the T P Valve openin...

Страница 11: ...Provisions made to protect area from water damage Sufficient room to service heater Water Supply Water heater completely filled with water Air purged from water heater and piping Water connections tig...

Страница 12: ...h as air escaping through the pipe as the water begins to flow Do not smoke or use an open flame near the faucet at the time it is open CAUTION The cause of the high temperature condition must be inve...

Страница 13: ...n be regulated by setting the temperature dial of the adjustable surface mounted thermostat s located behind the jacket access panel s Dual element heaters have two thermostats Safety and energy conse...

Страница 14: ...shorten the life of the glass lined tank and will exclude warranty coverage Care and cleaning of the water heater Draining the Water Heater CAUTION Shut off power to the water heater before draining w...

Страница 15: ...connect switch if used are in the ON position The thermostat may See the Temperature regulation of the water heater be set set too low section of this manual Leaking or open hot Make sure all faucets...

Страница 16: ...T attempt repair of electrical wiring thermostat s heating elements or other operating controls Refer repairs to qualified service personnel Relief valve Junction box cover Anode rod Hot outlet heat t...

Страница 17: ...til it breaks away from the remainder of the cavity insert See illustration to the left Discard the crossbar It cannot and need not be replaced Replace the thermostat and or element as necessary Repla...

Страница 18: ...X 4 L2 RED 1 3 2 UPPER THERMOSTAT HIGH TEMP LIMIT ECO UPPER HEATING ELEMENT BLUE YELLOW BLACK L1 G BRANCH CIRCUIT TO ELECTRICAL DISTRIBUTION PANEL 240 V JUNCTION BOX 4 L2 RED 1 3 1 2 BLACK RED BLACK L...

Страница 19: ...19 Rheem Manufacturing Company Warranty Registration Department P O Box 34070 Louisville KY 40232 4070 Please place in envelope and mail to Cut here Cut here...

Страница 20: ...Mr Ms Mrs Miss Street Address City State Date Placed In Use Month Day Year Zip Code Apt Last Name Phone Number _ _ Complete and mail this Consumer Product Ownership Registration today After mailing th...

Отзывы: