background image

Alliance Arming Station

Installation Instructions

4

Power up.  

Upon initial power-up, the beeper will sound 

two beeps indicating that the internal nonvolatile 
memory is okay. All of the area LEDs may illuminate, 
indicating that the system is armed. All areas must be 
disarmed in order to enable access to the installer 
programming menu options.

Text scrolling speed.  

You can change the text scrolling 

speed (for all LCD RAS in the system). Refer to the 
Alliance programming manual for details.

Programming

The AL-1116 is fitted with a Smart card reader. You can use an 
LCD RAS on the system data bus or a reader configuration card 
to configure (change from the default settings) smart card 
readers. The method you use depends on the reader’s mode 
setting in menu option 7, Security Mode. The modes are:

Unsecured mode (default setting).  

The reader is ready for 

use with unprogrammed or blank smart cards in IUM-
equipped systems. You may use either an LCD RAS or a 
reader configuration card to configure the reader, if required.

Secured mode.  

You must configure the reader via a reader 

configuration card before it can be used. The reader will 
recognize only programmed smart cards, in either IUM or 
non-IUM systems.

If used, the reader configuration card is programmed using Alli-
ance management software in conjunction with the AL-1623 
Smart Card Programmer.

Main menu

The programming menu is structured in two sections:

• Menus 1 to 6 are common to both AL-1111 and AL-1116 

models.

• Menus 7 to 12 apply only to the AL-1116 model.

To access the main menu, do the following:
1.

With all areas disarmed, press

 Menu

installer code

Enter.

2.

To access the installer programming menu, press 

19

Enter

Menu

28

Enter

.

3.

To access the RAS menu, press 

2

Enter

.

4.

Enter the 

RAS address

 and press 

Enter

.

You are now in the RAS main menu and the text display should 
be similar to the following:

GE Security, RAS111X, Vxx

0-Exit, Menu:

In the sample, 

111X

 is the product name and 

Vxx

 is the firmware 

revision number.

Navigation

The navigation sequence varies depending on where you are in 
the menu. Navigate the main menu in the following manner:

• Press 

Enter

 to scroll forward and 

Menu

 to scroll backward 

through the menu options.

• Each menu option has an associated option number. To 

select a menu option and open its submenu, enter the option 
number and press 

Enter

.

• Press 

0

Enter

 to exit the RAS main menu.

Submenus typically offer a choice between a default setting and 
alternative settings. Navigate the submenus in the following 
manner:

• Press 

Enter

 to accept the currently displayed setting and to 

return to the main menu.

• Press 

Menu

 to scroll to an alternative setting.

Menu options

The RAS menu provides numbered options. Options 7 to 12 
apply only to the AL-1116 Smart Card reader RAS.

1. Access LED

Use this option to enable (default) or disable the blue access 
LED.

2. Night light

A dimly lit keypad backlight provides a night light to easily 
locate the keypad in dark locations. Use this option to enable 
(default) or disable the night light.

3. Keypad backlight

The keypad backlight turns on bright for night time illumination 
of the key labels. Use this option to enable (default) or disable 
the keypad backlight.

4. Egress control

The unit is fitted with an egress (exit) control port (IN) on the 
wiring connector. When connected to a simple push button 
(

Figure 7

 on page 3), the OUT (open) collector terminal may be 

used to control a door relay.
Choose one of the following settings:

Egress only (default).  

This setting requires you to connect 

a simple push button to the IN terminal. A press of the 
button will release the door lock relay. Used for a quick 
exit from an area.

 Egress disabled.  

When the IN terminal is not used, we 

recommend that you use the egress disable setting.

5. Reserved

Menu 5 is reserved for future development.

6. Factory defaults

Use this option to return all settings to factory defaults (if appli-
cable) shown in 

Table 1

.

7. Security mode

Use this option to select the type of user card the AL-1116 reader 
will recognize. The reader will recognize configuration and 
default cards in both mode settings.

Secured mode.  

Only cards programmed on AL-1623 

programmers will be recognized in this mode. The 4-
byte security password is used.

Unsecured mode.  

The reader will recognize blank or 

unprogrammed cards only, by using the card’s unique 
serial number. The 4-byte security password is not 
used. Unsecured mode (default) requires an expanded 
memory system.

8. Valid card flash

Use this option to enable (default) or disable the blue LED flash 
when a valid card is badged at the AL-1116 reader.

Table 1.

Factory defaults

Menu option

Default setting

1. Access LED

Enabled

2. Night light

Enabled

3. Keypad backlight

Enabled

4. Egress control

Egress only

7. Security mode

Secured mode

8. Valid card flash

Enabled

9. Protocol options

Wiegand format

10. Card beeps

Enabled

11. Option card

Enabled

Содержание AL-1111

Страница 1: ...one of the pins away from the body of the unit and pull Figure 1 Unit front 2 The metal mounting plate at the back of the unit is held by a locking screw Figure 2 To remove the mounting plate loosen the screw by at least 0 3 in 8 mm slide the mounting plate down and then pull the bottom of the mounting plate away from the body of the unit Figure 2 Unit back and mounting plate 3 Attach the mounting...

Страница 2: ...e RS 485 system bus You can connect the unit up to 5 000 ft 1 5 km from the control panel or 4 door elevator controller DGP We recommend you use a Beldon 8723 twisted pair shielded data cable The shield of any system bus cable must be connected to system ground at one end only This unit does not provide an Earth connection for this purpose If you daisy chain the system bus to the unit ensure that ...

Страница 3: ...to arm Operating features The unit includes the following features Keyboard backlight and night light By default the keyboard backlight is on bright for approximately 4 15 minutes following a key press The night light by default is on dim To change these options see Menu options on page 4 LCD contrast To adjust the LCD contrast press and hold the Menu key Figure 1 on page 1 while you press the Up ...

Страница 4: ...ter Press 0 Enter to exit the RAS main menu Submenus typically offer a choice between a default setting and alternative settings Navigate the submenus in the following manner Press Enter to accept the currently displayed setting and to return to the main menu Press Menu to scroll to an alternative setting Menu options The RAS menu provides numbered options Options 7 to 12 apply only to the AL 1116...

Страница 5: ... or disable the use of reader configuration cards at the AL 1116 reader If you wish to prevent modification of the reader setup by configuration card you should disable this option 12 Last card Use this option to display the number of the last card badged at the AL 1116 reader The format shows the facility code and the ID number Offline mode If the unit has power available but loses communication ...

Страница 6: ...to radio or tele vision reception which can be determined by turning the equip ment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet or a circuit different than that to which the receiver is connected...

Отзывы: