background image

Instillation Instructions

 

 these instructions with the appliance.

OWNER: Keep these instructions for future use.

Electrical 

Please Read Carefully.

How to connect electricity

For personal safety, this
appliance must be properly
grounded.

Electrical requirement

 models 

require a 

volt a.c., 60 

 grounded outlet

protected with a 15 amp time delay
fuse or circuit breaker.

The power cord on these models has
a three-prong (grounding) plug that
mates with a standard three-prong
(grounding) wall outlet (Fig. 1) to
minimize the possibility of electric
shock hazard from these appliances.

230/208-volt models 

require their

own single branch circuit supplying
230/208-volt a.c., protected with a
time delay fuse or circuit breaker.
This is recommended for best
performance and to prevent
overloading house wiring circuits,
which could cause a possible fire
hazard from overheating wires.

The power cord on these models
has a 230/208-volt perpendicular,

tandem or large tandem type plug
that mates respectively with a
230/208-volt perpendicular,
tandem or large tandem type wall
outlet. These types of outlets are
available at most hardware stores.

PREFERRED
METHOD

Fig. 1

.

 

‘@q

.

INSURE PROPER 
EXISTS BEFORE USE

Where a standard two-prong wall
outlet is encountered, it is your

MATCHING

PERPENDICULAR TYPE WALL OUTLET

LINE CORD PLUG

REQUIRES 20 AMP TIME DELAY FUSE

OR CIRCUIT BREAKER PROTECTION

230/208-VOLT

MATCHING

TANDEM TYPE

WALL OUTLET

LINE CORD PLUG

REQUIRES 15 AMP TIME DELAY FUSE

OR CIRCUIT BREAKER PROTECTION

\

230/208-VOLT

MATCHING

LARGE TANDEM TYPE

WALL OUTLET

LINE CORD PLUG

REQUIRES 30 AMP TIME 

 FUSE

OR CIRCUIT BREAKER PROTECTION

Whether your air conditioner is a

 or a 230/208-volt unit, it

is important to have the wall
outlet and circuit checked by a
qualified electrician if there is

personal 

 and 

any doubt as to whether a proper

to have it replaced with a properly

ground exists.

grounded three-prong wall outlet.

DO NOT, 

 

 

OR 

 

 THIRD

 PRONG FROM

 POWER CORD.

8

Содержание AJ806L

Страница 1: ...lem Solver 7 Care and Cleaning 6 Safety Instructions 2 Condenser Coils 6 User Maintenance Instructions 6 Consumer Services 15 Warranty Back Cover Control Settings 3 4 Electrical Requirements 8 Energy Saving Tips 5 Extension Cords 9 GEAmwer Cente Grille and Cabinet 6 8M 6262000 Cool Only Models AJ806L AJX06L AJ808A AJX08A AJ81OA AJM1OA AJX09D AJM1OD AJA12D GEAppiances ...

Страница 2: ...ructions before it is used See grounding instructions on page 9 Never unplug your air conditioner by pulling on the power cord Always grip plug firmly and pull straight out from the receptacle Repair or replace immediately dl electric service cords that have become frayed or otherwise damaged Do not use a cord that shows cracks or abrasion damage along its length or at either the plug or connector...

Страница 3: ... the air inside the room can be circulated and conditioned When operation without cookg or heatig it s in the OPEN position some LOW FAN provides low fan indoor air can be exhausted from speed operation without cooling the room or heating LOW COOL provides cooling with low fan speed operation HIGH COOL provides cooling with high fan speed operation Fan Switih The Fan Switch located behind the If y...

Страница 4: ...tor Switch at LOW COOL for very quiet operation and the Thermostat Control at mid range 5 or 6 When the Thermostat Control is set on 9 or 10 and the Fan is set on low speed moisture may freeze on the coils and prevent the unit from cooling If this happens set the Fan at high speed and set the Thermostat Control to a lower number For Extreme Temperatures For greatest economy and best performance we...

Страница 5: ...r smoke or odors from the room Don t let the room get too hot or too cold Whenever possible turn the unit on before the room heats up or cools down Keep windows and doors closed Conditioned air escapes when they re open Keep furnace floor registers and cold air returns closed Conditioned air can easily escape through them Don t block front of unit when it is operating Curtains or drapes blocking i...

Страница 6: ...e through your GE service outlet Air Elter The air filter behind the front grille should be checked and cleaned at least every 30 days or as often as it needs cleaning To remove the filter Grasp the tab at the air outlet on the front grille and pull it straight up Clean the filter with a vacuum cleaner to remove light dust Wash the filter in lukewarm soapy water and rinse in clear water to remove ...

Страница 7: ...urns Ventilation Control maybe set at OPEN allowing outside air to enter room Cooling coils have iced up To melt ice set the Fan at high speed and the Thermostat Control to a lower number OPERATING Thermostat click a metallic sound maybe heard when compressor cycles on and off SOUNDS This is normal Fan cycles on and off with compressor when Fan Switch behind front grille is at UCLE and Selector Sw...

Страница 8: ...230 208 volt perpendicular tandem or large tandem type plug that mates respectively with a 230 208 volt perpendicular tandem or large tandem type wall outlet These types of outlets are available at most hardware stores PREFERRED METHOD Fig 1 VP n q 1 INSURE PROPERGROUNO EXISTS BEFORE USE Where a standard two prong wall outlet is encountered it is your 230 20B VOLT MATCHING PERPENDICULAR TYPE WALL ...

Страница 9: ...t ground the appfiance unless cover screw is meti and not insulated and wdl outlet is grounded through house wiring You should have the circuit checked by a qudifid electrician to make sure the outlet is properly grounded men diseonneetingthe power cord from the adapter always hold the adapter with one hand If this is not done the adapter ground terminal is very likely to break with repeated use S...

Страница 10: ... screwdriver Adjustable wrench Wood saw c Scissors or knife Window Requirements Standard double hung window with actual opening width of 31 to41 Clear vertical opening of 17 minimum from bottom of sash to stool Stool offset height between sill and stool must be less than 1 Yz Note All supporting parts should be secured to firm wood masonry or metal L 31 to41 10 ...

Страница 11: ...e 3 Loosen the ground screw B then remove the ground wire Save the ground wire for reinstallation later I Grille Screws Short 4 Pull the bottom corners of the clhassis and slide it out from the c abinet Note The rear grille may be installed from the room side with 2 short screws provided with the grille 3 Instill Hller Curtains 1 Install the top mounting rail onto the top of the cabinet with 4 pe ...

Страница 12: ...side 3 Pull the window sash down on top of the unit For safety purposes attach the sash locking brackets with 4 type A screws 2 on each side 4 Cut the foam sash gap gasket to window width and stuff it between the top of the lower sash and glass panes of the upper sash The foam gasket should be flush with the top of the lower sash Window S 11 Q Gasket Seal small openings around the cabinet with gum...

Страница 13: ...mp provided Ground Wire on M8 models disconnected when the chassis was removed from the cabinet must be reconnected to the cabinet as shown in step 3 under Prepare the Chassis on page 11 WHEN THE LINE CORD RUN IS TO THE LEFT SIDE OF THE UNIT extend enough cord to reach the wall receptacle Excess cord length may be stored in the space just below the electrical component box Insert the line cord und...

Страница 14: ...Notes 14 ...

Страница 15: ...Pur chase a GE contract while your war ranty is still in effect and you ll receive a substantial discount With a multiple year contract you re assured of future service at today s prices Telecommunication Device for the Deaf Pafls andAccessories 800 626 2002 Individu qutiled to service tieir own appliances can have needed parts or accessories sent direcdy to their home free of shipping charge The ...

Страница 16: ...trips to teach you how to use the product Read your Use and Care material If you then have any questions about operating the product please contact your dealer or our Consumer Affairs office at the address below or call toll free GE Answer Cente 800 626 2000 consumer information service Improper installation If you have an installation problem or if the air conditioner is of improper cooling or he...