8.2.6 High Frequency Board
1.
Remove upper capacitor bank assembly in accordance with instructions.
2.
Disconnect cable from connector MK100 on high frequency board.
3.
Remove two screws (T25) from high frequency board.
4.
Remove one nut (8mm) from high frequency board standoff and remove board.
Reassembly is done in reverse order.
1
2
3
130BX258.10
1
T25 screw (step 3)
3
8mm retaining nut (step 4)
2
High frequency board
High Power Service Manual for Unit Sizes 6x
114
8
Содержание AF-650 GP Series
Страница 31: ...High Power Service Manual for Unit Sizes 6x 30 3...
Страница 39: ...Illustration 3 5 Intermediate and inverter sections High Power Service Manual for Unit Sizes 6x 38 3...
Страница 41: ...Illustration 3 7 Inverter section High Power Service Manual for Unit Sizes 6x 40 3...
Страница 43: ...Illustration 3 8 Brake option High Power Service Manual for Unit Sizes 6x 42 3...
Страница 97: ...High Power Service Manual for Unit Sizes 6x 96 7...
Страница 111: ...High Power Service Manual for Unit Sizes 6x 110 8...
Страница 121: ...High Power Service Manual for Unit Sizes 6x 120 9...
Страница 134: ...11 Block Diagrams High Power Service Manual for Unit Sizes 6x 133 11...
Страница 135: ...Illustration 11 1 Unit Size 6x drive Top Level Block Diagram High Power Service Manual for Unit Sizes 6x 134 11...