EN-13 Link Speed
Option:
Function:
Forces the link speed for each port in 10 or 100 Mbps. If par. EN-12 is set to: ON, this parameter is read
only and displays the actual link speed. “None” is displayed if no link is present.
[0] *
None
[1]
10 Mbps
[2]
100 Mbps
EN-14 Link Duplex
Option:
Function:
Forces the duplex for each port to Full or Half duplex. If par. EN-12 is set to: ON, this parameter is read
only.
[0]
Half duplex
[1] *
Full duplex
EN-21 Process Data Config Write
Range:
Function:
[[0 - 9] PCD read 0 - 9]
Configuration of readable process data.
NB!
For configuration of 2-word (32-bit) parameter read/write, use 2 consecutive arrays in par. EN-21 and EN-22.
EN-22 Process Data Config Read
Range:
Function:
[[0 - 9] PCD read 0 - 9]
Configuration of readable process data.
EN-28 Store Data Values
Option:
Function:
This parameter activates a function that stores all parameter values in the non-volatile memory (EEPROM)
thus retaining parameter values at power-down.
The parameter returns to “Off”.
[0] *
Off
The store function is inactive.
[1]
Store All set-ups
All parameter value will be stored in the non-volatile memory, in all four setups.
EN-29 Store Always
Option:
Function:
Activates function that will always store received parameter data in non-volatile memory (EEPROM).
[0] *
Off
[1]
On
Modbus TCP
39
6