– 44 –
Microwave
Place standard test
load in oven.
Program time cook
for 30 seconds.
Does oven start
without pushing
start button?
Perform Control
Panel Test.
Pass test?
YES
Replace main
PCB.
YES
Replace control
panel.
NO
Does oven time
out and turn off?
NO
NO
Replace main
PCB.
YES
Perform
Microwave
Performance Test.
Pass test?
YES
Normal.
YES
Did temperature
rise but less than
28° F?
NO
Check line voltage
under full load.
Voltage OK?
Notify customer of
electrical problem.
High voltage
system
malfunction.
YES
Check relay RY2
om main PCB.
Relay OK?
NO
Replace main
PCB.
NO
YES
NO
High voltage
system
malfunction.
YES
Press start button.
Do fan and lights
come on?
YES
Perform Control
Panel Test.
Pass test?
NO
Replace control
panel.
NO
Check interlocks.
Interlocks OK?
Repair or replace
interlock.
NO
YES