– 18 –
Oven/Bake Operation Map
Shaded areas indicate relay contacts closed.
Function
Relay
reached target temp.
No.
start
end
Upper Heater,
Ry8
Ceramic
Upper Heater,
Ry3
Halogen
Lower Heater,
Ry9
Ceramic
MAG
Ry2
Upper Heater,
Ry7
Sheath
Oven Lamp
Ry1
Fan Motor
Ry6
(for MAG)
Convection
Ry16
Motor
Vent Fan,
Ry11
High
Vent Fan,
Ry12
Low
Vent Fan,
Ry13
Slow
Damper
Ry10
Motor
Cook Top
Ry14
Lamp, Hi
Cook Top
Ry15
Lamp, Lo
When base thermostat
is actuated.
Damper closed
When cavity Temp.
exceeds 425° F.
When cavity Temp.
exceeds 425° F.
Damper opens 10 min.
after cook time ends.
Содержание Advantium 120 SCA1000
Страница 15: ... 13 GEA01122 Figure 3 Vent Fan Airflow ...
Страница 16: ... 14 Notes ...
Страница 17: ... 15 Notes ...
Страница 59: ... 57 Schematics and Wiring Diagrams 02 05 2 12 8 Ω 2 5 Ω 22 5Ω 36 6 Ω B Y 32 Ω G R 7 Ω B W 18 Ω W G 24 Ω ...