Chapter 4: Web-Based Management
134
GE-DS-82 and 82-PoE Ethernet Managed Switch User Manual
OBJECT DESCRIPTION
Power Limit
It can limit the port PoE supply watts.
Per port maximum value must less 15.4, total ports values must less
than the Power Reservation value.
Once power overload detected, the port will auto shut down and keep
on detection mode until PD’s power consumption lower than the power
limit value.
NOTE:
For GE-DS-82-PoE, the total PoE power reservation from Port-1-8 is up to
180W.
PD Classifications
A PD may be classified by the PSE based on the classification information provided by
the PD. The intent of PD classification is to provide information about the maximum
power required by the PD during operation. Class 0 is the default for PDs. However, to
improve power management at the PSE, the PD may opt to provide a signature for
Class 1 to 3.
The PD is classified based on power. The classification of the PD is the maximum
power that the PD will draw across all input voltages and operational modes.
A PD shall return Class 0 to 3 in accordance with the maximum power draw as
specified by the table below.
Class
Usage
Range of maximum power used by the PD
0
Default
0.44 to 12.95 Watts
1
Optional
0.44 to 3.84 Watts
2
Optional
3.84 to 6.49 Watts
3
Optional
6.49 to 12.95 Watts
4
Not Allowed
Reserved for Future Use
NOTE:
Class 4 is defined but is reserved for future use. A Class 4 signature cannot be
provided by a compliant PD.
Содержание 82-POE
Страница 1: ...GE Security P N 1069182 REV 1 0 ISS 23FEB10 GE DS 82 and 82 PoE Ethernet Managed Switch User Manual ...
Страница 26: ...Chapter 2 Installation 22 GE DS 82 and 82 PoE Ethernet Managed Switch User Manual ...
Страница 148: ...Chapter 5 Console Management 144 GE DS 82 and 82 PoE Ethernet Managed Switch User Manual ...
Страница 212: ...Chapter 6 Command Line Interface 208 GE DS 82 and 82 PoE Ethernet Managed Switch User Manual ...
Страница 226: ......