4 - 16
750/760 FEEDER MANAGEMENT RELAY – COMMUNICATIONS GUIDE
MEMORY MAP
CHAPTER 4: MODBUS MEMORY MAP
03B2
Time of Fault 0 (2 words)
---
---
F22
---
03B4
Type of Fault 0
---
---
F76
---
03B5
Distance to Fault 0
–327.68 to 327.67
km, mi
F52
---
03B6
Line Z1 to Fault 0 (magnitude)
0.00 to 655.35
ohms
F53
---
FAULT LOCATION 1 (read only actual values)
03B8
Date of Fault 1 (2 words)
---
---
F23
---
03BA
Time of Fault 1 (2 words)
---
---
F22
---
03BC
Type of Fault 1
---
---
F76
---
03BD
Distance to Fault 1
–327.68 to 327.67
km
F52
---
03BE
Line Z1 to Fault 1 (magnitude)
0.00 to 655.35
ohms
F53
---
FAULT LOCATION 2 (read only actual values)
03C0
Date of Fault 2 (2 words)
---
---
F23
---
03C2
Time of Fault 2 (2 words)
---
---
F22
---
03C4
Type of Fault 2
---
---
F76
---
03C5
Distance to Fault 2
–327.68 to 327.67
km
F52
---
03C6
Line Z1 to Fault 2 (magnitude)
0.00 to 655.35
ohms
F53
---
FAULT LOCATION 3 (read only actual values)
03C8
Date of Fault 3 (2 words)
---
---
F23
---
03CA
Time of Fault 3 (2 words)
---
---
F22
---
03CC
Type of Fault 3
---
---
F76
---
03CD
Distance to Fault 3
–327.68 to 327.67
km
F52
---
03CE
Line Z1 to Fault 3 (magnitude)
0.00 to 655.35
ohms
F53
---
FAULT LOCATION 4 (read only actual values)
03D0
Date of Fault 4 (2 words)
---
---
F23
---
03D2
Time of Fault 4 (2 words)
---
---
F22
---
03D4
Type of Fault 4
---
---
F76
---
03D5
Distance to Fault 4
–327.68 to 327.67
km
F52
---
03D6
Line Z1 to Fault 4 (magnitude)
0.00 to 655.35
ohms
F53
---
FAULT LOCATION 5 (read only actual values)
03D8
Date of Fault 5 (2 words)
---
---
F23
---
03DA
Time of Fault 5 (2 words)
---
---
F22
---
03DC
Type of Fault 5
---
---
F76
---
03DD
Distance to Fault 5
–327.68 to 327.67
km
F52
---
03DE
Line Z1 to Fault 5 (magnitude)
0.00 to 655.35
ohms
F53
---
FAULT LOCATION 6 (read only actual values)
03E0
Date of Fault 6 (2 words)
---
---
F23
---
03E2
Time of Fault 6 (2 words)
---
---
F22
---
03E4
Type of Fault 6
---
---
F76
---
03E5
Distance to Fault 6
–327.68 to 327.67
km
F52
---
03E6
Line Z1 to Fault 6 (magnitude)
0.00 to 655.35
ohms
F53
---
FAULT LOCATION 7 (read only actual values)
03E8
Date of Fault 7 (2 words)
---
---
F23
---
03EA
Time of Fault 7 (2 words)
---
---
F22
---
03EC
Type of Fault 7
---
---
F76
---
03ED
Distance to Fault 7
–327.68 to 327.67
km
F52
---
03EE
Line Z1 to Fault 7 (magnitude)
0.00 to 655.35
ohms
F53
---
FAULT LOCATION 8 (read only actual values)
03F0
Date of Fault 8 (2 words)
---
---
F23
---
03F2
Time of Fault 8 (2 words)
---
---
F22
---
03F4
Type of Fault 8
---
---
F76
---
03F5
Distance to Fault 8
–327.68 to 327.67
km
F52
---
03F6
Line Z1 to Fault 8 (magnitude)
0.00 to 655.35
ohms
F53
---
Table 3: Modbus Memory Map (Sheet 11 of 40)
ADDR
DESCRIPTION
RANGE
UNITS
TYPE
DEFAULT
1 2 3 4 5 6 7 8 9 10 11 12 13
For explanation of Table footnotes, see the Memory Map Notes at the end of this table.