10
• Once the switch is part of the network, the same basic
procedure is used to add the switch to groups & scenes or
change advanced functions. Refer to the primary controller’s
instructions for details.
Please Note: After a power failure, the 45609 switch returns to the
last used state.
ADVANCED OPERATION
The following Advanced Operation parameters require that you
have an advanced controller like the GE model 45601 LCD remote.
Advanced remotes from other manufacturers may also be able to
change these settings; however, basic remotes do not have this
capability.
All On/All Off
Depending upon your primary controller, the 45609 switch can
be set to respond to ALL ON and ALL OFF commands in up to four
different ways. Some controllers may not be able to change the
response from its default setting. Please refer to your controller’s
instructions for information on whether or not it supports the con-
figuration function and if so, how to change this setting.
The four possible responses are:
It
will
respond to ALL ON and the ALL OFF command (default).
It
will not
respond to ALL ON or ALL OFF commands.
It
will
respond to the ALL OFF command but
will not
respond to
the ALL ON command.
It
will
respond to the ALL ON command but
will not
respond to
the ALL OFF command.
LED Light
When shipped from the factory, the LED is set to turn ON when the
connected light is turned OFF. This allows the LED to indicate the
switch’s location in a dark room. This is the default setting and can
be changed if your primary controller supports the node configu-
ration function. To make the LED turn ON when the light is turned
ON, change parameter 3’s value to “1”.
• Parameter No: 3
• Length: 1 Byte
• Valid Values = 0 or 1 (default 0)