Manufactured for: General Electric Company, Louisville, KY 40225
EPA EST. No. 070595-MN-001
Performance Data Sheet
SmartWater Filtration System
MWF Cartridge
This system has been tested according to NSF/ANSI 42/53 for reduction of the substances listed below.
The concentration of the indicated substances in water entering the system was reduced to a concentration
less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42/53.*
(100% safety factors built in for unmetered usage)
Standard No. 42: Aesthetic Effects
Parameter
USEPA
Influent
Influent
Effluent
% Reduction
Min. Required
MCL
Challenge Concentration
Average
Average
Maximum
Average
Minimum
Reduction
Chlorine
—
2.0 mg/L + 10%
1.96 mg/L
0.06 mg/L
0.11 mg/L
96.77%
94.74%
> 50%
T & O
—
—
—
—
—
—
—
—
Particulate**
—
≥
10,000 particles/mL
6,400,000 #/mL
58,833 #/mL
150,000 #/mL
99.14%
97.97%
≥
85%
Standard No. 53: Health Effects
Parameter
USEPA
Influent
Influent
Effluent
% Reduction
Min. Required
MCL
Challenge Concentration
Average
Average
Maximum
Average
Minimum
Reduction
Turbidity
0.5 NTU
11 + 1 NTU***
10.5 NTU
0.14 NTU
0.28 NTU
98.54%
97.20%
0.5 NTU
Cysts
≥
99.95% Reduction
Minimum 50,000 L
118,750 #/L
< 1 #/L
4 #/L
> 99.99%
> 99.99%
≥
99.95%
Asbestos
≥
99% Reduction
10
7
to 10
8
fibers/L; > 10µm
57 MF/L
0.996 MF/L
< 1 MF/L
99.60%
99.39%
≥
99%
Lead at pH 6.5
0.015 mg/L
0.15 mg/L + 10%
0.1567 mg/L < 0.001 mg/L
< 0.001 mg/L
99.36%
99.29%
0.010 mg/L
Lead at pH 8.5
0.015 mg/L
0.15 mg/L + 10%
0.1433 mg/L < 0.001 mg/L
< 0.001 mg/L
99.30%
99.29%
0.010 mg/L
Mercury at pH 6.5
0.002 mg/L
0.006 mg/L + 10%
0.0059 mg/L 0.000350 mg/L
0.0007 mg/L
94.70%
87.50%
0.002 mg/L
Mercury at pH 8.5
0.002 mg/L
0.006 mg/L + 10%
0.0057 mg/L 0.000325 mg/L
0.0006 mg/L
93.20%
89.29%
0.002 mg/L
Alachlor
0.002 mg/L
0.04 mg/L + 10%
0.0367 mg/L 0.00023 mg/L
0.0004 mg/L
99.34%
98.67%
0.002 mg/L
Lindane
0.0002 mg/L
0.002 mg/L + 10%
0.0020 mg/L < 0.00002 mg/L < 0.00002 mg/L
99.00%
98.95%
0.0002 mg/L
2,4-D
0.070 mg/L
0.210 mg/L + 10%
0.2033 mg/L 0.00337 mg/L 0.011000 mg/L
98.32%
94.50%
0.070 mg/L
Toxaphene
0.003 mg/L
0.015 mg/L + 10%
0.0160 mg/L 0.00100 mg/L 0.001000 mg/L
93.44%
91.67%
0.003 mg/L
Benzene
0.005 mg/L
0.015 mg/L + 10%
0.0145 mg/L 0.000500 mg/L 0.000500 mg/L
96.51%
95.83%
0.005 mg/L
Carbofuran
0.040 mg/L
0.080 mg/L + 10%
0.0830 mg/L 0.001000 mg/L 0.001000 mg/L
98.78%
98.65%
0.04 mg/L
1,4 dichlorobenzene
0.075 mg/L
0.225 mg/L + 10%
0.2283 mg/L 0.000500 mg/L 0.000500 mg/L
99.78%
99.77%
0.075 mg/L
Atrazine
0.003 mg/L
0.009 mg/L + 10%
0.0087 mg/L < 0.0005 mg/L < 0.0005 mg/L
94.22%
93.33%
0.003 mg/L
* Tested using a flow rate of 0.50 gpm; pressure of 60 psig; pH of 7.5 ± 0.5; temp. of 68° ± 5°F (20° ± 3°C)
** Measurement in Particles/ml. Particles used were 0.5-1 microns
*** NTU=Nephelometric Turbidity units
Operating Specifications
■
Capacity: certified for up to 300 gallons (1135 l); up to six
months for models without a replacement filter indicator light;
up to one year for models with a replacement filter indicator light
■
Pressure requirement: 40–120 psi (2.8–8.2 bar), non-shock
■
Temperature: 33–100ºF (0.6–38ºC)
■
Flow rate: 0.5 gpm (1.9 lpm)
General Installation/Operation/Maintenance Requirements
■
Flush new cartridge at full flow for 3 minutes to purge out
trapped air.
■
Replace cartridge when the indicator light flashes or water
flow rate is reduced on non-indicator units.
Special Notices
■
Installation instructions, parts and service availability, and standard
warranty are included with the product when shipped.
■
This drinking water system must be maintained according to
manufacturer’s instructions, including replacement of filter cartridges.
■
Do not use with water that is microbiologically unsafe or of unknown
quality without adequate disinfection before or after the system.
Systems certified for cyst reduction may be used on disinfected water
that may contain filterable cysts.
■
The contaminants or other substances removed or reduced by this
water treatment system are not necessarily in your water.
■
Check for compliance with the state and local laws and regulations.
■
Note that while the testing was performed under standard laboratory
conditions, actual performance may vary. Systems must be installed and
operated in accordance with manufacturer’s recommended procedures
and guidelines.
NSF
®
System Tested and Certified by NSF International against
ANSI/NSF Standard 42 & 53 for the reduction of:
State of California
Department of Health Services
Water Treatment Device
Certificate Number
Date Issued:
February 2, 2005
Trademark/Model Designation
Replacement Elements
1698
05 -
MWF
MWF
Manufacturer:
General Electric Company
The water treatment device(s) listed on this certificate have met the testing requirements pursuant to Section
116830 of the Health and Safety Code for the following health related contaminants:
Cysts
Turbidity
Asbestos
Lead
Mercury
Alachlor
Atrazine
Benzene
Carbofuran
Lindane
Mercury
Toxaphene
1,4-dichlorobenzene
2,4-D
Microbiological Contaminants and Turbidity
Inorganic/Radiological Contaminants
Organic Contaminants
Do not use where water is microbiologically unsafe or with water of unknown quality, except that systems certified for
cyst reduction may be used on disinfected waters that may contain filterable cysts.
300 gal
Rated Service Capacity:
0.5 gpm
Rated Service Flow:
Conditions of Certification:
19
Standard No. 42: Aesthetic Effects
Chemical Unit
Chlorine Taste and Odor
Mechanical Filtration Unit
Particulate Reduction, Class I
Standard No. 53: Health Effects
Chemical Reduction Unit
Alachlor and Atrazine Reduction
Benzene and Carbofuran Reduction
1,4 dichlorobenzene and 2,4-D Reduction
Lead and Lindane Reduction
Mercury and Toxaphene Reduction
Mechanical Filtration Unit
Turbidity Reduction
Cyst and Asbestos Reduction
Содержание 197D3351P020
Страница 21: ...Cut here...