Location 25 - Zones 1 to 8 zone type

Location 25 has eight segments of numerical data. Use this 
location to program the zone type for zones 1 to 8. Use 
segment 1 for zone 1, segment 2 for zone 2, etc. The segment 
defaults are 

3

5

6

6

6

6

6

6

Zones are programmed to be one of thirty different types. Use 
zone types 17 through 20 for wireless, or for hardwired zones 
using European double EOL configuration

Table 5

 describes the zone types. 

Table 5.

Zone types

Zone type 

Description 

1. Day zone

This zone is instant when the system is armed; 

trouble zone when the system is disarmed.

2. 24-hour audible.

This zone creates an instant yelping siren 

alarm regardless of the armed state of the 

control panel.

3. Entry/exit delay 1

A trip starts entry delay 1. The lack of a trip 

during exit delay enables the automatic 

bypass or instant mode if programmed.

4. Follower with autoby-

pass disabled

This zone is instant when the system is armed 

and no entry or exit delays are being timed. It 

is delayed 1 time during entry and exit. This 

zone does not automatically bypass even if 

enabled in segment 1. 

5. Interior follower with 

autobypass

This zone is instant when the system is armed 

and no entry or exit delay is being timed. It is 

delayed 1 time during entry and exit. This 

zone automatically bypasses if enabled in 

segment 1. 

6. Instant

This zone creates an instant alarm whenever 

it is tripped and the armed LED is on.

7. 24-hour silent

This zone creates an instant silent alarm 

regardless of the armed state of the control 

panel. It does not display on the keypad.

8. Fire

This zone illuminates the fire LED and sounds 

the temporal siren each time the zone is 

shorted. The fire LED flashes rapidly indi-

cating a problem if the zone is open. 

9. Entry/exit delay 2

A trip starts entry delay 2. The lack of a trip 

during exit delay enables the automatic 

bypass or instant mode if programmed. 

10. 24-hours silent super-

vised

This zone creates an instant silent alarm 

regardless of the armed state of the control 

panel. It displays on the keypad.

11. Reserved
12. Interior follower with 

cross zone

This zone is instant when the system is armed 

and no entry or exit delay is being timed. It is 

delayed during entry and exit delay times. If a 

cross zone

 is not being timed, it starts a 

cross 

zone

 timer. If a 

cross zone

 is being timed, it 

creates an instant alarm. This zone automati-

cally bypasses when enabled in segment 1.

13. Instant entry guard

This zone creates on instant alarm whenever 

it is tripped and the stay LED is off. It starts an 

entry delay type 2 if it is tripped, the system is 

armed, and the stay LED is on.

14. Entry/exit delay 1 with 

group bypass

A trip starts entry delay 1. This zone bypasses 

when the group bypass command is entered 

at the keypad. The lack of a trip during exit 

delay enables the automatic bypass or 

instant mode if programmed.

15. Interior follower with 

group bypass

This zone is instant when the system is armed 

and no entry or exit delays are being timed. It 

is delayed during entry/exit delay times. This 

zone bypasses when the group bypass 

command is entered at the keypad. This zone 

automatically bypasses if enabled in segment 

1. 

16. Instant with group 

bypass

This zone creates an instant alarm whenever 

it is tripped and the armed LED is on. This 

zone bypasses when the group bypass 

command is entered at the keypad.

17. Entry/exit delay 1 with 

tamper

A trip starts entry delay 1. The lack of a trip 

during exit delay enables the automatic 

bypass or instant mode if programmed. This 

zone type is used to enable the tamper on a 

wireless transmitter.

18. Interior follower with 

tamper and autobypass

This zone is instant when the system is armed 

and no entry or exit delay is being timed. It is 

delayed during entry and exit delay times. 

This zone automatically bypasses if enabled 

in segment 1. This zone type is used to enable 

the tamper on a wireless transmitter.

19. Instant with tamper

This zone creates an instant alarm whenever 

it is tripped and the armed LED is on. This 

zone type is used to enable the tamper on a 

wireless transmitter.

20. Entry/exit delay 2 with 

tamper

A trip starts entry delay 2. The lack of a trip 

during exit delay enables the automatic 

bypass or instant mode if programmed. This 

zone type is used to enable the tamper on a 

wireless transmitter.

21. Gas detection

This zone creates an instant alarm regardless 

of the armed state of the control panel. It 

displays on the keypad and activates the 

keypad sounder.

22. Low temperature 

detection

This zone creates an instant silent alarm 

regardless of the armed state of the control 

panel. It displays on the keypad and activates 

the keypad sounder.

23. High temperature 

detection

This zone creates an instant silent alarm 

regardless of the armed state of the control 

panel. It displays on the keypad and activates 

the keypad sounder.

24. Manual fire

This zone illuminates the fire LED and sounds 

the temporal siren each time the zone is 

shorted. It also flashes (rapidly) the fire LED, 

indicating a problem if the zone is open.

25. Chime only

This zone creates no alarm regardless of the 

armed state of the control panel. It chimes 

anytime it is faulted and displays on the 

keypad. Local only.

26. Interior follower delay 2

This zone is instant when the system is armed 

and no entry or exit delay is being timed. It is 

delayed 2 times during entry and exit. This 

zone automatically bypasses if enabled in 

segment 1. 

27. Interior follower force 

armable

This zone is instant when the system is armed 

and no entry or exit delay is being timed. It is 

delayed 1 time during entry and exit. This 

zone automatically bypasses if enabled in 

segment 1.

28. Entry/exit force 

armable delay 2

A trip starts entry delay 2. The lack of a trip 

during exit delay enables the automatic 

bypass or instant mode if programmed.

29. Interior follower with 

activity supervision

This zone is instant when the system is armed 

and no entry or exit delay is being timed. It is 

delayed during entry and exit delay times. It 

sends a report if the zone activity time is 

reached without a change of state. This zone 

automatically bypasses if enabled in segment 

1. 

30. Entry/exit with activity 

supervision

A trip starts entry delay 1. It sends a report if 

the zone activity time is reached without a 

change of state. The lack of a trip during exit 

delay enables the automatic bypass or 

instant mode if programmed.

Table 5.

Zone types (continued)

Zone type 

Description 

Содержание NetworX Series NX-8V2

Страница 1: ...ted in location 37 this output becomes voltage output 12 VDC 1 Amp maximum load Note A 3 3 kohm resistor may be required across the bell terminals when a 12 VDC siren is used If no resistor is used you may experience voltage leakage into the siren which will cause these devices to output a small signal KP DATA Connect to the data terminal on the keypads and the expanders Maximum number of devices ...

Страница 2: ...previous location Press the Medical key for the same location 5 To review the data in a specific location repeat the above procedure pressing but with no numeric data entry Each time you press the programming data of the next segment displays Exit a location To exit the current programming location do the following 1 Press the key The Ready LED goes off and the Armed LED goes on You must press the...

Страница 3: ...f numerical data Use this loca tion to program the communicator format used to transmit to the receiver connected to phone 1 Refer to your central station receiver documentation to determine which format is compatible Table 4 describes the formats for this location If you need a format other than those listed review the over ride options described in Location 18 Custom communicator format on page ...

Страница 4: ... restores 2 Opening and closings 3 Zone bypass and bypass restores 4 Zone trouble and trouble restores 5 Power fail low battery power restore and low battery restore 6 Bell cut telephone line cut bell cut restore telephone line restore 7 Test reports 8 Start and end programming download complete Segment 2 1 Zone and box tamper and tamper restore 2 Auxiliary power overcurrent ground fault and resto...

Страница 5: ...tomatically bypasses if enabled in segment 1 16 Instant with group bypass This zone creates an instant alarm whenever it is tripped and the armed LED is on This zone bypasses when the group bypass command is entered at the keypad 17 Entry exit delay 1 with tamper A trip starts entry delay 1 The lack of a trip during exit delay enables the automatic bypass or instant mode if programmed This zone ty...

Страница 6: ...ad sounder If the late to close early to open feature is enabled the opening and closing reports must be enabled For Canadian installations the class II transformer secure tab must not be employed The four wire smoke detector employed must be rated to operate over the voltage range of 11 5 to 12 4 V Compatible listed devices special applications Bell output sirens Wheelock models NS 1215W NS 12157...

Страница 7: ... based on three 17 A batteries Table 6 Use markings Model number Use marking Subassemblies NX 8 S Res Fire1 and Burg2 Com Burg4 Acc5 Homehealth Care Control Unit Motherboard NX 8E S Res Fire1 and Burg2 Com Burg4 Acc5 Homehealth Care Control Unit Motherboard NX 8V2 S Res Fire1 and Burg2 Com Burg4 Acc5 Homehealth Care Control Unit Motherboard NX 508 NX 508E Res Fire1 and Burg2 Com Burg4 Acc5 Output ...

Страница 8: ...structions 8 CAUTION Observe polarity when installing a new battery Installing the battery backwards may cause damage to the panel Dispose of used batteries according to the manufacturer s instructions and or local government authorities ...

Страница 9: ...is feature is not programmable in the panel Exit time and progress are always enabled Enabled disabled for remote arming Entry delays b b Combined abort window time and entry delay must not exceed one minute Entry 1 delay 24 1 30 30 to 240 seconds Entry 2 delay 24 3 30 30 to 240 seconds Abort window for nonfire zones Dialer delay 40 8 30 Enabled may be disabled by zone zone type but no cancel repo...

Страница 10: ... draw Without sounder Dimensions 110 mA max 75 mA 6 4 x 5 3 x 1 0 in 16 3 x 13 5 x 2 5 cm Metal enclosure dimension 11 25 x 11 25 x 3 50 in 28 58 x 28 58 x 8 90 cm Shipping weight 9 lb 4 1 kg FCC This device complies with part 15 of the FCC rules Operation is subject to the following conditions 1 This device may not cause harmful interference 2 This device must accept any interference received inc...

Отзывы: