3

Loading factory defaults

To load factory defaults, enter program mode, enter the 
device address and number and then enter 

9, 1, 0, #

. The 

keypad beeps three times indicating that loading is in 
progress. The process takes about six seconds. You cannot 
exit the location until loading is completed.

Enrolling modules and keypads

The NX-8V2 automatically finds and stores all keypads, zone 
expanders, wireless receivers, and other modules connected 
to the data terminal into the NX-8V2 memory. This allows the 
modules to be supervised by the control panel.
To enroll the modules, do the following:
1.

Enter program mode and program the desired settings 
for each module.

2.

When you exit program mode, the NX-8V2 automatically 
enrolls the devices. The enrolling process takes about 12 
seconds, during which time the Service LED illuminates. 
If a speaker is attached to the NX-8V2, it clicks at this 
time. If a siren or bell is attached to the NX-8V2, it sounds 
for about one second. If the module is not detected, the 
Service LED illuminates.

Note:  

User codes are not accepted during the enrolling 

process. 

Quick start programming locations

For most routine installations, the quick start locations allow 
you to enable a majority of the options available with the NX-
8V2 (when communicating in Contact ID or SIA formats). The 
quick start locations include:

• Location  0  -  Phone  1
• Location 1 - Phone 1 account code
• Location 2 - Phone 1 communicator format
• Location 3 - Phone 1 dial attempts/backup control

Location 0 - Phone 1

Location 0 has 20 segments of numerical data. Use this loca-
tion to program phone 1. The default for each segment is 

14

.

• To program a delay of four seconds, enter 

13

 in the 

appropriate segment.

• To program tone dialing, enter 

15

 in the segment where 

tone dialing begins.

• If the entire number is tone dialing, enter 

15

 in the first 

segment.

• Enter 

11

 for a 

*

, and 

12

 for a 

#.

Location 1 - Phone 1 account code

Location 1 has six segments of numerical data. Use this loca-
tion to program the account code sent when phone 1 is 
dialed. The default for each segment is 

10

. Program a 

10

 in 

the segment immediately after the last digit of the account 

code. If the account code is six digits long, program all six 
segments. 

Location 2 - Phone 1 communicator format

Location 2 has one segment of numerical data. Use this loca-
tion to program the communicator format used to transmit 
to the receiver connected to phone 1. Refer to your central 
station receiver documentation to determine which format is 
compatible. 

Table 4

 describes the formats for this location. If 

you need a format other than those listed, review the over-
ride options described in 

Location 18 - Custom communicator 

format

 on page 4 to build the appropriate format. Program a 

15 

to create a special format (in addition to the entries in 

Location 18). The default is 

0

. If this location contains a 

0

, the 

built-in communicator is disabled and the NX-8V2 functions 
as a local-only control.

CAUTION:  

A call-waiting cancel on a noncall-waiting 

line prevents successful connection to the central 
station.

Table 4.

Communicator formats

Data

Format

Description

0

Local 

Communicator is disabled

1

Universal 4+2

Two-digit event code 1800 Hz transmit 

2300 Hz handshake double round parity 

40 pps 

a

2

3+1 fast (or 4+1)

One-digit event code 1900 Hz transmit 

1400 Hz handshake double round parity 

20 pps

3

Reserved

Reserved

4

Pager

Two-digit event code DTMF transmis-

sion 

5

3/1 or 4/1 slow

1800 Hz transmit 2300 Hz handshake 

double round parity 20 pps hex capa-

bility

6

3/1 or 4/1 slow 

1800 Hz transmit 1400 Hz handshake 

double round parity 20 pps hex capa-

bility

7

3/1 or 4/1 fast

1800 Hz transmit 2300 Hz handshake 

double round parity 40 pps hex capa-

bility

8

3/1 or 4/1 fast

1800 Hz transmit 1400 Hz handshake 

double round parity 40 pps hex capa-

bility

9

3/1 or 4/1 fast with parity

1800 Hz transmit 2300 Hz handshake 

single round parity 40 pps hex capa-

bility

10

3/1 or 4/1 fast with parity  1800 Hz transmit 1400 Hz handshake 

single round parity 40 pps hex capa-

bility

11

4+2 express

Two-digit event code DTMF transmis-

sion

12

4+2 fast

Two-digit event code 1900 Hz transmit 

1400 Hz handshake double round parity 

20 pps

13

Ademco contact ID

DTMF 

14

SIA

Frequency shift keys

15

Custom format

See 

Location 18 - Custom communi-

cator format

 

16

3/1 or 4/1 slow

Same as 5, but sends the alarm event 

code rather than the zone number

17

3/1 or 4/1 slow

Same as 6, but sends the alarm event 

code rather than the zone number

18

3/1 or 4/1 fast

Same as 7, but sends the alarm event 

code rather than the zone number

19

3/1 or 4/1 fast

Same as 8, but sends the alarm event 

code rather than the zone number

20

3/1 or 4/1 fast with parity

Same as 9, but sends the alarm event 

code rather than the zone number

Содержание NetworX Series NX-8V2

Страница 1: ...ted in location 37 this output becomes voltage output 12 VDC 1 Amp maximum load Note A 3 3 kohm resistor may be required across the bell terminals when a 12 VDC siren is used If no resistor is used you may experience voltage leakage into the siren which will cause these devices to output a small signal KP DATA Connect to the data terminal on the keypads and the expanders Maximum number of devices ...

Страница 2: ...previous location Press the Medical key for the same location 5 To review the data in a specific location repeat the above procedure pressing but with no numeric data entry Each time you press the programming data of the next segment displays Exit a location To exit the current programming location do the following 1 Press the key The Ready LED goes off and the Armed LED goes on You must press the...

Страница 3: ...f numerical data Use this loca tion to program the communicator format used to transmit to the receiver connected to phone 1 Refer to your central station receiver documentation to determine which format is compatible Table 4 describes the formats for this location If you need a format other than those listed review the over ride options described in Location 18 Custom communicator format on page ...

Страница 4: ... restores 2 Opening and closings 3 Zone bypass and bypass restores 4 Zone trouble and trouble restores 5 Power fail low battery power restore and low battery restore 6 Bell cut telephone line cut bell cut restore telephone line restore 7 Test reports 8 Start and end programming download complete Segment 2 1 Zone and box tamper and tamper restore 2 Auxiliary power overcurrent ground fault and resto...

Страница 5: ...tomatically bypasses if enabled in segment 1 16 Instant with group bypass This zone creates an instant alarm whenever it is tripped and the armed LED is on This zone bypasses when the group bypass command is entered at the keypad 17 Entry exit delay 1 with tamper A trip starts entry delay 1 The lack of a trip during exit delay enables the automatic bypass or instant mode if programmed This zone ty...

Страница 6: ...ad sounder If the late to close early to open feature is enabled the opening and closing reports must be enabled For Canadian installations the class II transformer secure tab must not be employed The four wire smoke detector employed must be rated to operate over the voltage range of 11 5 to 12 4 V Compatible listed devices special applications Bell output sirens Wheelock models NS 1215W NS 12157...

Страница 7: ... based on three 17 A batteries Table 6 Use markings Model number Use marking Subassemblies NX 8 S Res Fire1 and Burg2 Com Burg4 Acc5 Homehealth Care Control Unit Motherboard NX 8E S Res Fire1 and Burg2 Com Burg4 Acc5 Homehealth Care Control Unit Motherboard NX 8V2 S Res Fire1 and Burg2 Com Burg4 Acc5 Homehealth Care Control Unit Motherboard NX 508 NX 508E Res Fire1 and Burg2 Com Burg4 Acc5 Output ...

Страница 8: ...structions 8 CAUTION Observe polarity when installing a new battery Installing the battery backwards may cause damage to the panel Dispose of used batteries according to the manufacturer s instructions and or local government authorities ...

Страница 9: ...is feature is not programmable in the panel Exit time and progress are always enabled Enabled disabled for remote arming Entry delays b b Combined abort window time and entry delay must not exceed one minute Entry 1 delay 24 1 30 30 to 240 seconds Entry 2 delay 24 3 30 30 to 240 seconds Abort window for nonfire zones Dialer delay 40 8 30 Enabled may be disabled by zone zone type but no cancel repo...

Страница 10: ... draw Without sounder Dimensions 110 mA max 75 mA 6 4 x 5 3 x 1 0 in 16 3 x 13 5 x 2 5 cm Metal enclosure dimension 11 25 x 11 25 x 3 50 in 28 58 x 28 58 x 8 90 cm Shipping weight 9 lb 4 1 kg FCC This device complies with part 15 of the FCC rules Operation is subject to the following conditions 1 This device may not cause harmful interference 2 This device must accept any interference received inc...

Отзывы: