![GE Security CareGard Скачать руководство пользователя страница 11](http://html.mh-extra.com/html/ge-security/caregard/caregard_user-manual_572135011.webp)
Performing System Tests
7
5. Press
Done.
The panel announces
“Sensor test OK.”
Testing Voice Event Notification
Testing the Voice Event Notification feature requires you to activate your per-
sonal help button or press the panel
Call
button. To prevent a test failure, you
must also answer the secondary or event notification phone.
¾
To test Voice Event Notification:
1. If your panel is monitored, contact your central monitoring station and inform
the operator that you are testing your panel.
2. Press your personal help button
or
the panel
Call
button.
3. Answer the secondary or voice event phone. The panel announces
“Press
STAR for alarm.”
4. On the phone, press
*
to hear each alarm. The panel announces
“Sensor XX
panic alarm.”
• If the call ends and you did not press
*,
the panel calls the programmed
number eight times.
• After reviewing each alarm, press
5
to enter a two-way audio session or go
to Step 5. Refer to Table 2 for a list of accessible remote phone commands.
5. On the phone, press
#
to terminate the call.
Table 1: Activating a Sensor
How do I activate a...
You simply...
Personal Help / Pendant
Help Button
Press and hold the help button until the red
light flashes.
Door / Window Sensor
Open a door or window that has a sensor.
Freeze Sensor
Remove sensor cover and press
Program.
Water Sensor
Remove sensor cover and press
Program.
Smoke Alarm
Press
Test
on the smoke alarm.
Carbon Monoxide Alarm
Unplug the alarm and plug it back in. Press
Test/Reset
until the alarm sounds six beeps.
Motion Sensor
Remove motion sensor from mounting plate.
Repeater
Remove cover and press
Tamper Switch.
Touchpad / Keychain
Press and hold the two
emergency buttons.
Keychain Touchpad
Press and hold the
lock
and
unlock
buttons.