FS-9001OM
– REV M
iii
Copyright 2016 GE Reuter-Stokes. All rights reserved
Certification Information
ATTENTION!
The RS-FS-9001
Flame Tracker
sensor complies with the following standards:
ETL
Control Number 9900287
Class 1, Div. 2, Grp A,B,C,D T3
Class 1, Zone 2 AEx nA IIC T3 Gc
ATEX / IECEx
Temperature Range
-40ºC ≤ T
a
≤ 150ºC; T3
-40ºC ≤ T
a
≤ 235ºC; T2 ; with cooling coil
These certifications are based on the use of approved interconnecting cables only. Currently available approved
interconnecting cables are GE Reuter Stokes RS-E2-0285PXXX and GE 362A1053PXXX. See Section 1.1.2 for
details
.
WARNING
Certifications are based on the use of approved cables only. Currently available approved cables are GE Reuter-
Stokes RS-E2-0285 and GE 362A1053.
Do not attempt to disassemble the sensor. Sensor is not repairable. Breaching the seal of the sensor will cause
lose of the inert fill gas and render the sensor unusable.
Do not remove the sensor by wrenching on the body. Always use the 1 3/8 inch mounting nut. Wrenching on the
body may breach the seal. Breaching the seal of the sensor will cause lose of the inert fill gas and render the
sensor unusable. Once the seal has been broken it cannot be resealed by reassembly.
Do not install a sensor that has a cracked window, damaged threads or one that has been disassembled.
CAUTION
The operating temperature range of the Flame Sensor is
-40°C to 150°C
.
Do not
attempt to work on the Flame
Sensor until it has reached a safe handling temperature.
0359
II 3 G
Ex nA IIC T3 Gc