Note:
50 - 60 in. lbs = 5.6 - 6.8 Nm. When installing the Water Cooling Coil, ensure that the edge of the
Sheet Metal Band is not in contact with the cooling tubes. This will ensure that no rubbing or fretting of the
cooling tubes by t
he band’s edge will occur during turbine operation.
1. Apply a small amount of Never-Seez PN NG-165 (GE PN 248A9779P001) to threads, prior
to reinstalling the Flame Sensor
2. Inspect the window and clean with Isopropanol soaked swab. If required install hand tight
(3-4 Full turns) tighten with a wrench approximately 2.5 turns. Tighten further as required to
align keys on cable connector with slots in sensor connector
3. Slide cooling coil over Flame Sensor major diameter and orient tubes on the coil as required
for assembly. Tighten clamps 50-60 in. lbs. Install Swagelok fittings re-torque clamps to 50-
60 in. lbs. after first shut down