CHAPTER 13: MODBUS MEMORY MAP
8 SERIES PROTECTIVE RELAY PLATFORM – COMMUNICATIONS GUIDE
13-301
83764
0xAAF3 Pickup
1
3000000
1
kW
F11
10000
2
Y
83766
0xAAF5 Relays
0
0xFFFFFFFF
1
FC198
0
2
Y
83768
0xAAF7 Block
0
0xC6CD00
1
FC142
0
2
Y
83770
0xAAF9 Events
0
1
1
FC126
1
1
Y
83771
0xAAFA Targets
0
2
1
FC101
1
1
Y
Real Power Demand 3
83785
0xAB08 Function
0
4
1
FC100A 0
1
Y
83786
0xAB09 Signal Input
0
3
1
FC286
0
1
Y
83787
0xAB0A Measurement Type
0
2
1
FC254
0
1
Y
83788
0xAB0B Thermal 90% Response
Time
0
4
1
FC255
2
1
Y
83789
0xAB0C Time Interval
0
4
1
FC255
3
1
Y
83790
0xAB0D Pickup
1
3000000
1
kW
F11
10000
2
Y
83792
0xAB0F Relays
0
0xFFFFFFFF
1
FC198
0
2
Y
83794
0xAB11 Block
0
0xC6CD00
1
FC142
0
2
Y
83796
0xAB13 Events
0
1
1
FC126
1
1
Y
83797
0xAB14 Targets
0
2
1
FC101
1
1
Y
Real Power Demand 4
83811
0xAB22 Function
0
4
1
FC100A 0
1
Y
83812
0xAB23 Signal Input
0
3
1
FC286
0
1
Y
83813
0xAB24 Measurement Type
0
2
1
FC254
0
1
Y
83814
0xAB25 Thermal 90% Response
Time
0
4
1
FC255
2
1
Y
83815
0xAB26 Time Interval
0
4
1
FC255
3
1
Y
83816
0xAB27 Pickup
1
3000000
1
kW
F11
10000
2
Y
83818
0xAB29 Relays
0
0xFFFFFFFF
1
FC198
0
2
Y
83820
0xAB2B Block
0
0xC6CD00
1
FC142
0
2
Y
83822
0xAB2D Events
0
1
1
FC126
1
1
Y
83823
0xAB2E Targets
0
2
1
FC101
1
1
Y
Reactive Power Demand 1
83863
0xAB56 Function
0
4
1
FC100A 0
1
Y Y Y Y
83864
0xAB57 Signal Input
0
3
1
FC286
0
1
Y
Y
83865
0xAB58 Measurement Type
0
2
1
FC254
0
1
Y Y Y Y
83866
0xAB59 Thermal 90% Response
Time
0
4
1
FC255
2
1
Y Y Y Y
83867
0xAB5A Time Interval
0
4
1
FC255
3
1
Y Y Y Y
83868
0xAB5B Pickup
1
3000000
1
kvar
F11
10000
2
Y Y Y Y
83870
0xAB5D Relays
0
0xFFFFFFFF
1
FC198
0
2
Y Y Y Y
83872
0xAB5F Block
0
0xC6CD00
1
FC142
0
2
Y Y Y Y
83874
0xAB61 Events
0
1
1
FC126
1
1
Y Y Y Y
83875
0xAB62 Targets
0
2
1
FC101
1
1
Y Y Y Y
Reactive Power Demand 2
83889
0xAB70 Function
0
4
1
FC100A 0
1
Y
83890
0xAB71 Signal Input
0
3
1
FC286
0
1
Y
83891
0xAB72 Measurement Type
0
2
1
FC254
0
1
Y
83892
0xAB73 Thermal 90% Response
Time
0
4
1
FC255
2
1
Y
Modbus
Address
Hex
Address
Description
Min
Max
Step Units
Format
Code
Factory
Default
Size in
Words
8
5
0
8
6
9
8
8
9
8
4
5
Содержание 845
Страница 26: ...3 6 8 SERIES PROTECTIVE RELAY PLATFORM COMMUNICATIONS GUIDE REAL TIME CLOCK CHAPTER 3 TIME PROTOCOLS ...
Страница 40: ...4 14 8 SERIES PROTECTIVE RELAY PLATFORM COMMUNICATIONS GUIDE DNP IMPLEMENTATION CHAPTER 4 DNP PROTOCOL ...
Страница 54: ...6 10 8 SERIES PROTECTIVE RELAY PLATFORM COMMUNICATIONS GUIDE INTEROPERABILITY CHAPTER 6 IEC 60870 5 104 ...
Страница 86: ...8 24 8 SERIES PROTECTIVE RELAY PLATFORM COMMUNICATIONS GUIDE THE IEC 61850 CONFIGURATOR CHAPTER 8 IEC 61850 ...
Страница 788: ...14 294 8 SERIES PROTECTIVE RELAY PLATFORM COMMUNICATIONS GUIDE CHAPTER 14 FORMAT CODES ...
Страница 868: ...B 74 8 SERIES PROTECTIVE RELAY PLATFORM COMMUNICATIONS GUIDE PIXIT CHAPTER B IEC 61850 IMPLEMENTATION DETAILS ...