SOFTWARE COMMAND SUMMARY
Table 2
lists software commands commonly used during initial instal-
lation and setup of the transceiver. A complete list of commands and
detailed descriptions is contained in the
Reference Manual
.
Table 2. Command Summary
Command Name
Function
BAUD [xxxx xxx]
Sets radio’s serial data interface rate/format.
Default setting is BAUD 9600 8N1.
DATAKEY
Keys the transmitter on receipt of data.
DKEY
Dekey the radio (transmitter OFF). This is
generally a radio test command.
KEY
Key the radio (transmitter ON). This is
generally a radio test command.
MODEM [xxxx]
Set the modem characteristics of the radio.
PORT [RS232, RS485]
Selects signaling standard to be used on
COM2 DATA port. For RS-485 operation,
see
Reference Manual
.
PWR [20–37]
Set or display the transmit power setting.
PTTSIG [ON, OFF]
Set/display push-to-talk configuration.
RSSI
Display the Received Signal Strength
Indication.
RTSKEY
Set/display how the radio responds to RTS
keying. Default is RTSKEY ON, which
causes the radio to key the transmitter when
RTS is raised.
RTU [ON/OFF/0-80]
Re-enables or disables the radio’s internal
RTU simulator and sets the RTU address.
RX [xxx.xxxx]
Set or display receiver frequency.
SER
Display the radio serial number.
SNR
Signal-to-Noise Ratio (in dB).
SPECTRUM
[xxx.xx]
Display internal spectrum analyzer, where
xxx.xx
characters denote center frequency
in MHz. The command
spectrum
may be
entered alone to view current operating
channel.
SREV
Display the Software Revision Level.