Segment 2- Phone #1 Backup Control: Programming a "0" in Segment 2 of this location will cause the NX-8 to make
the designated number of attempts to Phone #2 before setting the "Fail To Communicate" condition and stop
reporting. Programming a "1" in this segment will cause the NX-8 to stop trying to communicate after the designated
number of attempts have been made to Phone #1. If a "2" is programmed in this segment, it will cause the NX-8 to
make the dial attempts in increments of two. The first two attempts will be made to Phone #1, the next two attempts to
Phone #2, then repeating until the total number of attempts designated in Segment 1 is completed.
FORMAT SELECTIONS
DATA
FORMAT
DESCRIPTION
0
Local
Communicator is disabled
1
Universal 4+2
Two digit event code 1800hz transmit 2300hz handshake double round parity
40pps
2
3+1 fast (or 4+1)
One digit event code 1900Hz transmit 1400Hz handshake double round parity
20pps
3
Reserved
Reserved
4
Pager
2 digit event code DTMF transmission
5
3/1 or 4/1 slow
1800hz transmit 2300hz handshake double round parity 20 p.p.s. hex capability
6
3/1 or 4/1 slow
1800hz transmit 1400hz handshake double round parity 20 p.p.s. hex capability
7
3/1 or 4/1 fast
1800hz transmit 2300hz handshake double round parity 40 p.p.s. hex capability
8
3/1 or 4/1 fast
1800hz transmit 1400hz handshake double round parity 40 p.p.s. hex capability
9
3/1 or 4/1 fast with parity
1800hz transmit 2300hz handshake single round w/parity 40 p.p.s. hex
capability
10
3/1 or 4/1 fast with parity
1800hz transmit 1400hz handshake single round w/parity 40 p.p.s. hex
capability
11
4+2 express
2 digit event code DTMF transmission
12
4+2 fast
Two digit event code 1900hz transmit 1400hz handshake double round parity
20 p.p.s.
13
Ademco Contact ID
DTMF (see pages 51-52)
14
SIA
FSK (see pages 51-52)
15
Custom format
(See location 18, page 16)
REPORTING EVENTS TO PHONE NUMBER 1
Phone #1 has two programming locations that are used to select which events are reported to this phone number.
Location 4 is used to select which events are reported to Phone #1. Location 5 is used to select which partitions are
reported to Phone #1. If dual or split reporting is not desired, location 4 should be used to select all events to Phone
#1 and location 5 should be left at the factory default of "0". If dual or split reporting is desired, and the split is based
on the event type (such as alarm, open/close, etc.), location 4 should be used to select only those events that should
be reported to Phone #1 and location 5 should be left at the factory default of "0". If dual or split reporting is desired,
and the split is based on partition, location 4 should be programmed as a "0" and location 5 should be used to select
those partitions that should be reported to Phone #1. If no events should be reported to Phone #1, both locations
should be programmed as "0" (disabling all options).
LOCATION 4 - EVENTS REPORTED TO PHONE # 1 (2 segments, feature selection data)
Segment 1:
1 = Alarms and Alarm Restores.
2 = Opening and Closings.
3 = Zone Bypass and Bypass Restores.
4 = Zone Trouble and Trouble Restores.
5 = Power Fail, Low Battery, Power Restore, and Low Battery Restore.
6 = Bell Cut , Telephone Line Cut, Bell Cut Restore, Telephone Line Restore.
7 = Test Reports.
8 = Start and End programming, Download complete.