Page 25
L
LOCATION 51 - AUTOTEST CONTROL (4 segments, numerical data)
Segment 1:
Program a "1" if the interval is to be in hours; Program a "0" if in days. Add a
A
2" to suppress the daily
test or a
A
3" to suppress the hourly test if any report has been sent.
Segment 2:
Program the Autotest interval from 1-255 hours/days.
Segment 3:
Program the Autotest report hour in 24 hour format (if the interval is in hours, this segment is ignored).
Segment 4:
Program the Autotest report time, number of minutes after the hour.
LOCATION 52 - OPENING TIME (2 segments, numerical data)
Location 52 contains the time in 24 hour format the NX-8 enables codes designated as arm only after closing. This
time is only valid on those days programmed in location 54. Note: Opening time must be earlier than closing time for
Auto Arm, Aux. Outputs, or Code Authorization to function properly.
Segment 1:
Program the hour of the opening time.
Segment 2:
Program the minutes after the hour of the opening time.
LOCATION 53 - CLOSING TIME/AUTOMATIC ARMING TIME (2 segments, numerical data )
Location 53 contains the time in 24 hour format the NX-8 disables the disarm capability for codes designated as arm
only after closing. This is also the time the Automatic Arming sequence will begin (if enabled in location 55). Note:
Opening time must be earlier than closing time for Auto Arm, Aux. Outputs, or Code Authorization to function properly.
Segment 1:
Program the hour of the closing / auto arm time.
Segment 2:
Program the minutes after the hour of the closing / auto arm time.
LOCATION 54 - DAYS OF THE WEEK EACH PARTITION IS OPEN (8 Segments, feature selection data)
Location 54 selects which days of the week each partition is open. On these days,
A
arm only after close window
@
codes will be able to arm and disarm during open window. NOTE: If any partition is not programmed to be opened
and is programmed to Auto-Arm (Location 55), the NX-8 will try to arm every 45 minutes for the duration of the
closed period. On days not selected here,
A
arm only after close window
@
codes will not disarm. Segment 1 is for
partition 1, and segment 8 is for partition 8. (See locations 52 and 53 for the opening and closing times for the
open days.)
Segment 1-8:
1 - Open on Sunday.
2 - Open on Monday.
3 - Open on Tuesday.
4 - Open on Wednesday.
5 - Open on Thursday.
6 - Open on Friday.
7 - Open on Saturday.
8 - Reserved.
LOCATION 55 - DAYS OF THE WEEK FOR AUTO ARMING IN PARTITIONS 1 THRU 8 (8 Segments, feature
selection data)
Location 55 selects which days each partition will auto arm. Segment 1 is for partition 1, and segment 8 is for partition
8. If a zone is faulted when the panel tries to auto arm, the zone will be bypassed.
Segments 1-8: 1 - Auto Arming on Sunday.
2 - Auto Arming on Monday.
3 - Auto Arming on Tuesday.
4 - Auto Arming on Wednesday.
5 - Auto Arming on Thursday.
6 - Auto Arming on Friday.
7 - Auto Arming on Saturday.
8 - Reserved.
Содержание NetworX NX-8
Страница 10: ...Page 10 PROGRAMMING EXAMPLE TO BE INSERTED HERE ...
Страница 60: ...Page 60 SYSTEM NOTES ...