background image

Model 840/845 Contactless Smart Card Reader

15

NO

TES 

(Unles

s ot

herw

ise

 spe

c

ifie

d):

1

.

470

-ohm

, 1/2

W

pull-u

p

 res

isto

is req

uired

 betw

e

e

n +

12VDC a

nd READER DA

T

A

 1

. T

he p

ull-up

 resi

stor s

houl

d be

 

in

st

a

lled

 at th

e

 m

icroc

ontroll

er

’s

 t

ermin

a

l b

lock. A res

isto

r is s

uppl

ied 

w

it

h

 the

 read

er

. M

icro

Pr

o

x

 do

es 

not re

quire 

th

is re

s

is

tor

.

2

.

Sh

ield

ed c

abl

e

 is

 reco

mme

nde

d in 

e

le

ctrica

lly 

nois

y

 en

v

iron

men

ts.

3

.

If

 u

s

ing 

sh

ield

ed 

cab

le, 

con

n

ec

a

ll 

s

h

ie

lds 

toge

ther 

a

the 

mi

cro 

end.

 C

on

nect

 t

groun

s

tud 

in 

the 

low

e

lef

c

o

rner 

o

f Mi

c

ro/5

 ca

b

ine

ts us

ing

 14 

A

W

G

 w

ire. No 

shie

ld c

onne

ctio

ns a

t the

 read

er

.

4.

If

 u

s

ing

 a

 l

o

c

a

l p

ow

er

 s

u

p

p

ly

d

o

 n

o

c

o

nn

e

c

+

1

2

V

 li

n

e

 f

ro

m t

h

e

 mi

c

ro

c

o

n

tr

o

ll

e

r t

o

 t

h

e r

e

a

d

e

r.

 H

o

w

e

ve

r,

 t

h

e

 n

e

g

at

iv

s

ide

 of the

 pow

e

s

upp

ly m

ust 

be c

onne

cte

d

 to 

the m

icro 

(pin 2

 on 

the re

ade

r port). 

K

e

e

the w

irin

g

 from

 pow

er 

s

uppl

y to 

reade

r les

s

 th

a

n 5

0

 fe

e

t.

5

.

Re

fer to 

the a

pprop

ri

ate 

sys

tem

 man

u

al 

to de

termi

n

e w

h

e

ther th

is c

onne

ctio

n is

 requi

red fo

door s

w

itch o

p

era

tion. 

6

.

B

locki

ng d

iode

s ma

y b

e

 1

N

4

14

8 or

 s

imil

ar

 (ins

tal

ler

 su

ppli

e

d) a

nd l

o

ca

ted i

n

 a s

ec

ur

ed a

rea.

7

.

Pr

o

tecti

on di

odes

 ma

y b

e

 1N

4

002

, 1N

4

003

, or

 1

N

400

4 (i

nst

a

ller

 s

upp

lied)

 for

 the

 doo

str

ike

 as

sem

bly

.

8

.

F

u

se

, pow

e

s

upp

ly

, do

o

r strike, a

nd re

lay 

are p

ro

v

id

ed b

y the

 ins

tall

e

r.

Содержание 840

Страница 1: ...rt Number 460394001E October 2002 Model 840 845 Contactless Smart Card Reader Installation Guide GE Interlogix CASI Division 791 Park of Commerce Boulevard Suite 100 Boca Raton Florida 33487 561 998 6100 ...

Страница 2: ...ch product into the total inventory of in house products While each offering has been reviewed for its compatibility and maintainability no assurance of successful installation can be given The customer accepts full maintenance responsibility A full scope of software and hardware maintenance contracts are available to the customer Copyright 1999 2002 GE Interlogix All Rights Reserved Printed in th...

Страница 3: ...istances 6 Pinouts 7 Communications Settings 9 Testing for Current Settings 9 Setting the Communications Mode CASI Mode 10 Setting the Communications Mode Native Mode 11 Digital Input Door Contact and Exit Request Supervised F 2F Mode Only 13 Testing the Reader 22 Troubleshooting Guide 23 Technical Specifications 26 Functional Specifications 27 Regulatory Notices 30 ...

Страница 4: ...l 84x Reader Wall Mounting 5 Figure 3 Model 84x Reader J2 Connector Location 8 Figure 4 Wiring Diagram Model 84x Supervised F 2F Mode 14 Figure 5 Wiring Diagram Model 84x Wiegand 4001 Mode 16 Figure 6 Wiring Diagram Model 84x Unsupervised F 2F Mode 18 Figure 7 Wiring Diagram Model 84x Omron Magstripe Strobe Mode 20 ...

Страница 5: ... this guide the abbreviation 84x will stand for reader Models 840 and 845 The 84x Reader is designed to mount on a standard U S single electrical gang box The Model 845 is identical to the Model 840 except for a built in twelve position keypad This feature makes this reader ideal for installations requiring keypad PIN entry in addition to a valid smart card read ...

Страница 6: ... switch status Microcontroller acknowledgments and commands Intelligent bidirectional communication between the reader and microcontroller which can be accomplished over 4 conductor telephone cable Weather resistant housing for outdoor use Standard 12V operation A clear logical user interface with three LEDs and a beeper Rugged molded polycarbonate construction with integral backplate Built in tam...

Страница 7: ...ing the Reader below 4 Test the reader Refer to Testing the Reader on page 22 5 If necessary refer to Troubleshooting Guide on page 23 for troubleshooting information Mounting the Reader The reader comes with a backplate suitable for mounting directly onto a standard U S electrical single gang box The reader may also be mounted directly onto a hollow wall The reader is supplied with a weather resi...

Страница 8: ...4 Model 840 845 Contactless Smart Card Reader FIGURE 1 Model 84x Reader Gang Box Mounting ...

Страница 9: ...Model 840 845 Contactless Smart Card Reader 5 FIGURE 2 Model 84x Reader Wall Mounting ...

Страница 10: ...f 24 AWG telephone wire 4 The reader will work well with unshielded cable in most environments No company can guarantee that data will be reliably transmitted for long distances on unshielded cable in every installation Typical Wiegand reader installation requires eight conductor shielded cable to provide reader power controller communication door contact exit push button and tamper switch status ...

Страница 11: ...or JP2 pin 1 is to the right as you view the connector from behind the reader See Figure 3 Model 84x Reader J2 Connector Location on page 8 TABLE 2 Pinouts for Connector J2 J2 Pin Signal 1 12VDC 2 Ground 3 Green LED 4 RS 232 Output 5 No Connection 6 Reader Data 7 Reader Data 1 8 Door DI Point 9 Door DI Return 10 Exit DI Point 11 Exit DI Return ...

Страница 12: ...8 Model 840 845 Contactless Smart Card Reader FIGURE 3 Model 84x Reader J2 Connector Location ...

Страница 13: ...move power from the reader 2 Place a mini jump over both pins of JP4 3 Add power to the reader and listen for the number of beeps NOTE The number of beeps indicate the current communications mode set 1 beep Supervised F 2F 2 beeps Unsupervised F 2F 3 beeps Strobe 4 beeps Wiegand 4001 5 beeps RS 232 4 Remove power from the reader 5 Place a mini jump over one 1 pin of JP4 6 Add power to the reader a...

Страница 14: ...circuit boards and higher 1 Remove power from the reader 2 Place a mini jump over both pins of JP4 JP3 is open 3 Add power to the reader and listen for the number of beeps NOTE The number of beeps indicate current communications mode set 1 beep Supervised F 2F 2 beeps Unsupervised F 2F 3 beeps Strobe 4 beeps Wiegand 4001 5 beeps RS 232 4 Push and release the tamper switch the number of times that ...

Страница 15: ...rinted circuit boards and higher 1 Remove power from the reader 2 Place a mini jump over both pins of JP4 and JP3 3 Add power to the reader and listen for the number of beeps NOTE The number of beeps indicate current communications mode set 1 beep Supervised F 2F 2 beeps Unsupervised F 2F 3 beeps Strobe 4 beeps Unused 5 beeps RS 232 4 Push and release the tamper switch the number of times the corr...

Страница 16: ...n remove power from the reader 6 Place a mini jump over one 1 pin of JP4 and remove JP3 7 Add power to the reader and resume normal operations NOTE Mode 4 is not available in Native Mode Beeping and flashing LEDs indicate that Mode 4 has erroneously been set in Native Mode ...

Страница 17: ...then end of line resistors two at 1 000 ohms each are required 1 Install the door contact and the two end of line resistors installer supplied at the contact 2 Wire the door contact end of line resistors to pin JP2 8 and pin JP2 9 3 Install the exit request contact and the two end of line resistors installer supplied at the contact 4 Wire the exit request end of line resistors to pin JP2 10 and pi...

Страница 18: ...14 Model 840 845 Contactless Smart Card Reader FIGURE 4 Wiring Diagram Model 84x Supervised F 2F Mode ...

Страница 19: ... Micro 5 cabinets using 14 AWG wire No shield connections at the reader 4 If using a local power supply do not connect 12V line from the microcontroller to the reader However the negative side of the power supply must be connected to the micro pin 2 on the reader port Keep the wiring from power supply to reader less than 50 feet 5 Refer to the appropriate system manual to determine whether this co...

Страница 20: ...16 Model 840 845 Contactless Smart Card Reader FIGURE 5 Wiring Diagram Model 84x Wiegand 4001 Mode ...

Страница 21: ...at the microcontroller s terminal block A resistor is supplied with the reader MicroProx may not require this resistor 3 If using a local power supply do not connect 12V line from the microcontroller to the reader However the negative side of the power supply must be connected to the micro pin 2 on the reader port Keep the wiring from power supply to reader less than 50 feet 4 Blocking diodes may ...

Страница 22: ...18 Model 840 845 Contactless Smart Card Reader FIGURE 6 Wiring Diagram Model 84x Unsupervised F 2F Mode ...

Страница 23: ... Micro 5 cabinets using 14 AWG wire No shield connections at the reader 4 If using a local power supply do not connect 12V line from the microcontroller to the reader However the negative side of the power supply must be connected to the micro pin 2 on the reader port Keep the wiring from power supply to reader less than 50 feet 5 Refer to the appropriate system manual to determine whether this co...

Страница 24: ...20 Model 840 845 Contactless Smart Card Reader FIGURE 7 Wiring Diagram Model 84x Omron Magstripe Strobe Mode ...

Страница 25: ... of the power supply must be connected to the micro pin 2 on the reader port Keep the wiring from power supply to reader less than 50 feet 2 Blocking diodes may be 1N4148 or similar installer supplied and located in a secured area 3 Protection diodes may be 1N4002 1N4003 or 1N4004 installer supplied for the door strike assembly 4 Fuse power supply door strike and relay are provided by the installe...

Страница 26: ...e microcontroller Refer to the appropriate microcontroller manual 5 Close the tamper switch by joining the reader and backplate When all wires are connected to the reader ensure that the supervision function is operating properly by verifying that the reader is not sounding a short triple beep every 30 seconds and that the red LED is not flashing slowly every 2 seconds If such an alarm is present ...

Страница 27: ...JP2 pin 1 power and JP2 pin 2 ground This voltage should be greater than 9VDC and less than or equal to the reader supply voltage If the voltage is too low correct the wiring If the voltage is correct replace the reader None of the LEDs are on Present a known good MIFARE 1 type card to the reader while listening for the beeper If the beeper sounds the reader is faulty and should be replaced If the...

Страница 28: ... seconds and the red LED flashes slowly every 2 seconds The reader has lost communication with the microcontroller 1 Check the reader to microcontroller wiring Refer to the appropriate installation drawing Verify that the AUX DO is jumpered to the reader data 1 on the microcontroller 2 Verify that the correct pull up resistor is installed on the microcontroller 3 Verify that the microcontroller ha...

Страница 29: ...he reader sounds a short triple beep every 30 seconds and the red LED is on continuously Check that the 4 state supervised switches are connected with two 1K ohm resistors to the door contact and the exit request inputs or if the inputs are not used that a 1K ohm resistor is installed at the reader connector See Figure 4 Wiring Diagram Model 84x Supervised F 2F Mode on page 14 ...

Страница 30: ...Product Catalog for part numbers and ordering information Maximum Cabling Distance The maximum cable distance between the reader and the microcontroller is influenced by a number of factors including wire gauge See Table 1 Cable Distances on page 6 NOTE The reader will work well with unshielded cable in most environments No company including GE Interlogix can guarantee that data will be reliably t...

Страница 31: ...efly 100 ms to indicate that a smart card has been read and sent to the microcontroller Blinks off while a key is pressed Model 845 only Green LED Indicates that the microcontroller has activated the door strike Flashes quickly every 400 ms to indicate a request for PIN entry Upon completion of the PIN entry the LED stops flashing Beeper A short triple beep sounds every 30 seconds to indicate lost...

Страница 32: ...to connector JP3 on the printed circuit board assembly and install the switch between the wall and reader backplate When the reader and the backplate are removed from the wall the switch will close therefore closing the connection causing a tamper condition Door Contact and Exit Request Inputs The 84x Readers have a 4 state supervised door contact switch input and an exit request switch input The ...

Страница 33: ...tions Modes 1 Wiegand 4001 Unsupervised F 2F and Omron Magstripe Strobe and RS 232 do not support the Door Contact and Exit Request Inputs 2 The use of PIN codes requires a Model 845 Contactless Smart Card Reader 3 PIN codes are supported for the following Modes only Supervised F 2F Wiegand 4001 4 Omron Magstripe Strobe Mode RS 232 Mode and Wiegand 4001 are provided for use with other systems 5 To...

Страница 34: ...g under the scope of R TTE Means of Conformity We declare under our sole responsibility that this product is in conformity with Directive 93 68 EEC Marking and or complies with the essential requirements and all other relevant provisions of the 1999 5 EC R TTE based on test results using harmonized standards in accordance with the Directives mentioned Concerning R TTE EMC Safety Radio A sample of ...

Отзывы: