4
5812-RND Acoustic Glassbreak Detector
Using the Hand-Clap Test and
Alarm Memory
The alarm memory and microphone operation can be
checked with the hand-clap test as follows:
1. Standing under the detector, clap your hands together.
2. Observe the LED on the detector.
If the detector has power and is functioning properly, the
LED quickly flashes twice.
If the detector has alarmed, the LED will light for 4 seconds.
Cycle the power to clear the alarm memory.
The hand-clap test is intended as a functional test, does not
open the relay, and is not an accurate indication of detector
range.
Maintaining the Detector
When installed and used properly, the detector provides
years of service with minimal maintenance. You should test
the detector annually to ensure proper operation.
Clean the cover with a damp (water) cloth as needed to keep
it free of dust and dirt. Always test the detector after
cleaning.
FCC Compliance
This device complies with Part 15 of the FCC rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference received,
including interference that may cause undesired operation.
Specifications
Input voltage ........................................ 12 VDC Nominal
Current
Typical ................................................................ 15mA
Maximum ............................................................. 25mA
Electrical configuration ........................................ Form A
Relay rating ............................................. 16V, 50mA max.
Detection range .................... 5’ - 25’ (1.5m - 7.6 m) x 360°
(use for rooms 100 sq. ft. and larger)
Alarm response ...................................................... 4 sec.
Minimum glass size ............... 12” x 24” (30.5 cm x 61 cm)
Recommended glass thickness:
Plate ................................ 3/32” - 1/4” (2.4 mm - 6.4 mm)
Tempered ......................... 1/8” - 1/4” (3.2 mm - 6.4 mm)
Wired ....................................................... 1/4” (6.4 mm)
Laminated ................................................ 1/4” (6.4 mm)
Operating temperature ................. 32° - 122° F (0° - 50°C)
Relative humidity ................... 10 - 90% non-condensing
Dimensions:
Depth ...................................................... 0.81” (2.1 cm)
Diameter .................................................. 4.0” (10.2 cm)
Color ..................................................................... White
Field wiring size ............................................ 18-24 AWG
Listing ............................................................... C-UL US
1038240 Rev A 06/02
12345 SW Leveton Drive
Tualatin, OR 97062
www.interlogixsecurity.com
www.sentrol.com
© 2002 GE Interlogix, Inc.
Phone: 503-692-4052
USA & Canada: 800-547-2556
Technical Service: 800-648-7424
FaxBack: 800-483-2495
GE Interlogix
Product Ordering
Model Number
Description
5812-RND
Acoustic glassbreak sensor, round housing, Form A
Accessories
5709C
Glassbreak hand-held tester