2
5812-RND Acoustic Glassbreak Detector
Selecting the Best Location for
Multiple Window Coverage
The detector has a 360degree coverage pattern that can be
used to cover several windows in a single room as follows:
•
Draw an imaginary line from the center of each window
to be covered in towards the center of the room.
•
Mount the detector as close to where the lines intersect
as possible. See Figure 3.
•
Do not mount the detector at more than a 60 degree
angle from the center of any window to be protected.
See Figure 3.
Installing the Detector
All wiring must conform to the National Electric Code
(NEC) and/or local codes having jursidiction.
Important !
Important !
Important !
Important !
Important !
If you are unsure about a location, connect a 9V
battery to the detector and test it before
permanently mounting. See Testing the Detector.
Use the following steps to install the detector:
1. Run the security system wiring to the detector location.
2. To remove the front cover, press the release tab on the
lip of the base, twist the cover counter clockwise, and
lift off. See Figure 4.
3. Remove the appropriate wiring and mounting
knockout holes from the base. See Figure 6.
4. Pull the wires through the knockout holes and use two
screws to attach the base to the surface. Use wall
anchors if necessary.
5. Strip 1/4 inch of insulation from each wire.
6. Connect the system wires to the appropriate screw
terminals on the base and tighten the screws. See
Figure 7.
7. To replace the cover, line up the tabs on the base with
the corresponding tabs on the cover, press together
and turn clockwise until the cover snaps firmly into
place. See Figure 5.
8. Apply power. The red LED should flash once.
9. Test the detector. See Testing the Detector.
Figure 3. Multiple Window Coverage
Figure 4. Housing Parts
Figure 5. Attaching the Cover
Figure 6. Detector Knockout Locations
Ceiling
Ceiling
Ceiling
Ceiling
Ceiling
mount
mount
mount
mount
mount
Detector
60 max.
60 max.
Microphone
LED
Release tab
Knockouts