![GE Grid Solutions MDS Master Station Скачать руководство пользователя страница 84](http://html.mh-extra.com/html/ge-grid-solutions/mds-master-station/mds-master-station_technical-manual_571877084.webp)
80
MDS™ Master Station
MDS 05-6399A01, Rev. F
Rekey Interval (AP only) –
The session key for an active secure link changes at a regular
basis. You may increase the length of the rekey interval in order to reduce overhead caused by
the rekeying communications between radios on a narrowband channel. Valid values:
-
0 – Rekeying will not be time-based, but will instead occur every one million packets.
-
30-525600 minutes, DEFAULT 180.
NOTE
Remember to click on the
Save
button when finished.
Advanced Configuration
Figure 5-9. Licensed Narrowband AP Advanced Settings
Figure 5-10 Licensed Narrowband (LN) Remote Advanced Settings
The Advanced Setting menu appears slightly different on APs than on Remotes.
Data Retries
- Number of times to retry unicast data before declaring failure. Valid values:
0—15
,
DEFAULT = 3.
Packet TTL (Time-to-Live)
– Length of time, in milliseconds, of inactivity of all over-the-air
traffic before registering a disconnection. The radio will then attempt to reconnect to the
network. Valid values: 100 to 65535 ms, DEFAULT = 2000 (2 seconds).
Содержание MDS Master Station
Страница 2: ......
Страница 4: ......
Страница 126: ...122 MDS Master Station MDS 05 6399A01 Rev F Remove four screws to remove the duplexer assembly from the tray ...
Страница 137: ......