![GE Grid Solutions MDS Master Station Скачать руководство пользователя страница 112](http://html.mh-extra.com/html/ge-grid-solutions/mds-master-station/mds-master-station_technical-manual_571877112.webp)
108
MDS™ Master Station
MDS 05-6399A01, Rev. F
Table 6-17. 400MHz LN Master Station Technical Specifications
Transmit (TX) Parameter
Specification
Frequency Range
330-406MHz (L4A) 406-470MHz (L4E)
1
Frequency Stability
<0.5 ppm, -30C to +60C
TX Power Out
+38.8dBm (-0.2/+0.35dB),, Peak at radio card for-30 to +60C
2
+37.2dBm (+/-0.5dB), Peak, in redundant configuration with
integrated duplexer
Agency Approvals
FCC Part 90 (L4E)
ETSI EN 300 113 (L4E)
1
Load VSWR
10:1 Max, All angles, No damage
Power Consumption
<45W for all DC and AC versions, 100% TX Duty Cycle
Receive (RX) Parameter
Specification
Frequency Range
330-406MHz (L4A) 406-470MHz (L4E)
RX Intermodulation
>60 dB
RX Adjacent Channel
>60 dB
RX Spurious and Image
>60 dB
RSSI Accuracy
+/-3 dB for RSSI -110 to -30 dBm
RX High RF Input Level
-20 dBm, no damage
Power Consumption
<30W for all DC and AC versions, transmitter disabled
Noise Figure
<4 dB
Operating Range
-30°C to +60°C
1
L4E ETSI Range = 333-406MHz.
2.
Peak and average power are based on modem type:
a.
64QAM, 16QAM: Average power is 7dB less than peak
b.
4QAM: Average power is 5dB less than peak