background image

9

English

8

How to operate your 
air-conditioner

• AUTO mode operation

In AUTO mode, the microcomputer
automatically controls the rate of cooling
and heating of the room (only cooling for
models GE AIR 326 and GE AIR 428). If the
room temperature is higher than 25ºC,
the unit will automatically switch to COOL
mode. On models PRO AIR I109 and PRO
AIR I112, if the room temperature is lower
than 20ºC, the unit will automatically
switch to HEAT mode. On all other
models, the unit switches to HEAT mode
below 18ºC. If the fan speed is set at
AUTO mode, the microcomputer will
control the speed of the indoor fan
according to the target temperature.

• FAN mode operation

Use the FAN mode to ventilate air in the
room without cooling, heating or drying
the air. Use the FAN button of the remote
controller to set the fan speed.

• TIMER ON operation

The TIMER ON mode can only be set while
the unit is not in operation. When the unit
is stopped, press TIMER ON button to turn
it on automatically at a specified time up
to 24 hours ahead. To cancel the TIMER
ON setting, press again TIMER ON button.

• TIMER OFF operation

The TIMER OFF mode can only be set
while the unit is in operation. When the
unit is in operation, press TIMER OFF
button to turn it off automatically at a
specified time up to 24 hours ahead. To
cancel the TIMER OFF function, press
again TIMER OFF button.

• COOL mode operation

The microcomputer automatically
controls the rate of cooling. It adjusts the
operation of the unit according to the
actual room temperature and the desired
temperature. If the room temperature is
higher than the desired temperature, the
unit will cool the air of the room. If the fan
speed is set at AUTO mode, the
microcomputer will control the speed of
the indoor fan according to the target
temperature.

• HEAT mode operation (not available on

models GE AIR 326 and GE AIR 428)
The microcomputer automatically
controls the rate of heating. It adjusts the
operation of the unit according to the
actual room temperature and the desired
temperature. If the room temperature is
lower than the desired temperature, the
unit will heat the air of the room. If the fan
speed is set at AUTO mode, the
microcomputer will control the speed of
the indoor fan according to the target
temperature.

• DRY mode operation

Use the DRY mode to both cool the air
and reduce the moisture contained in the
air. The microcomputer automatically
adjusts the operation of the unit
according to the actual dryness and
temperature of the room, and according
to the desired temperature. If the room
temperature is higher than the target
temperature, the unit will both cool and
dry the air of the room. If the fan speed is
set at AUTO mode, the microcomputer
will control the speed of the indoor fan
according to the target temperature.

• SLEEP mode operation

When the unit is cooling or drying and
operating in SLEEP mode, the target
temperature will gradually increase by
1°C per hour for two hours.
When the unit is heating and operating in
SLEEP mode, the target temperature will
gradually decrease by 1°C per hour for
two hours.

• Auto-restart function

If the network loses power, and if the unit
was in operation when the power cut
occurred, it will automatically restart
when the network regains power. 
On all models except GE AIR 116 and GE
AIR 121: if your air-conditioner was not in
operation before a power cut and
automatically switches on when the
network regains power, check the
following.
- Remove surface panel of indoor unit.
- Check the switch located on the right

of the unit is set on RUN.

- If it not set on RUN, use a screw driver

to set it to RUN.

AUTO

TEST

R U N

STOP

Содержание GE AIR 107

Страница 1: ...Wall Mounted Split Air Conditioner Owner s Manual and Installation Instructions GE Consumer Industrial Appliances GE imagination at work English ...

Страница 2: ...How to insert batteries 10 User notices 10 Care and maintenance 11 Troubleshooting 13 Installation instructions 15 Accessories and installation diagram 15 General installation instructions 16 Installing the indoor unit s 18 Installing the outdoor unit 23 Test operation and after installation check 25 Technical specifications 27 Models covered in this document GE GE AIR 107 GE AIR 109 GE AIR 112 GE ...

Страница 3: ...alled at least 2 0 m from the ground Extreme temperature differentials can be harmful to health Do not use the air conditioner for drying clothes preserving foods or other functions for which it was not designed Splashing water on the unit may cause an electric shock and malfunction The ground earthing wire must be properly connected Do not connect the earth wire to a gas or water pipe lightning r...

Страница 4: ...0 C HEAT mode not available on models GE AIR 326 and GE AIR 428 3 MODE button Select the desired mode of operation by pushing this button The unit can operate on AUTO COOL DRY FAN or HEAT modes Heat mode not available on models GE AIR 326 and GE AIR 428 4 FAN button Press this button to change fan speed There are three speeds to choose from or set the FAN to AUTO to let the unit control the air flo...

Страница 5: ...control the speed of the indoor fan according to the target temperature HEAT mode operation not available on models GE AIR 326 and GE AIR 428 The microcomputer automatically controls the rate of heating It adjusts the operation of the unit according to the actual room temperature and the desired temperature If the room temperature is lower than the desired temperature the unit will heat the air of...

Страница 6: ...emperature to save energy Keep the room approximately 5 C cooler than the outside temperature when operating in COOL mode Adjust the direction of the airflow appropriately Remember that warm air rises and cool air sinks so adjust the louver downward for heating and upward for cooling to take advantage of natural convection currents User notices CAUTION Always turn power off and remove the power plu...

Страница 7: ...enter Please check for the following 1 Is a power connection loose 2 Is the circuit breaker activated 3 Is the voltage higher than 253 volts or lower than 198 volts 4 Is TIMER ON in operation 1 Is the set temperature suitable 2 Is the air inlet or outlet obstructed 3 Are the air filters dirty or clogged 4 Is the indoor fan speed set too low 5 Is there another heat source in the room 1 Is the remote...

Страница 8: ... 2 5 4 5 Tapping screw 10 10 20 30 40 Plastic drain hose 1 1 2 3 4 Piping hole sleeve 2 2 4 6 8 Wrapping tape 1 1 2 3 4 Connection piping 1 1 2 3 4 Thermal insulation hose 1 1 2 3 4 Outdoor drain elbow 1 1 2 Outdoor drain stem 2 2 4 Air cleaner 2 2 4 6 8 Square ring 1 2 2 2 Immediately stop all operations disconnect the power and contact your nearest service center in the event any of the followin...

Страница 9: ...er before beginning installation to avoid possible malfunctions When picking up and moving the unit be guided by trained and qualified personnel The ground connection of the air conditioner must be made correctly and securely to the recommended earth ground points Contact the service center if you have any question Installation in the following places may cause malfunction Any place where machine o...

Страница 10: ...ter 11 Do not install the unit in the immediate vicinity of a laundry bath shower or swimming pool 12 The power plug must be accessible after the appliance is correctly positioned Install the rear panel 1 Always mount the rear panel horizontally 2 Fix the rear panel on the selected location with the screws supplied with the unit 3 Be sure the rear panel is firmly fixed The mounting must be able to w...

Страница 11: ...d value to operate the air conditioner safely 7 Wiring work must conform to national standards Model GE AIR 107 GE AIR 109 GE AIR 112 PRO AIR 107 PRO AIR 109 PRO AIR 112 GE AIR 116 GE AIR 121 GE AIR 218 GE AIR 224 PRO AIR 218 GE AIR 326 GE AIR 428 PRO AIR I109 PRO AIR I112 Indoor terminal block N 2 4 5 ground N 2 3 4 5 N 2 3 ground N 1 2 3 ground N 1 2 3 ground Cable wire Blue black violet orange ...

Страница 12: ...the connecting cable when fixing it with the wire clamp Make sure the wires are securely connected to the terminal block and the connecting cable is firmly held by the wire clamp Installing the outdoor unit Fig 3 Pipe diameter Torque mm Nm 6 35 15 20 9 52 31 35 12 7 50 55 15 8 60 65 Table 3 Install the piping hole 1 Make the piping hole Ø100 mm for models GE AIR 116 and GE AIR 121 and Ø80 mm for all...

Страница 13: ...it is connected to the power grid or after a power cut AUTO TEST R U N STOP Air purging and leakage test For models with multiple indoor units this procedure must be executed for each indoor unit This procedure requires a manifold valve and a vacuum pump 1 Make sure the liquid side valve and gas side valve are set to the closed position and check pipes are connected properly 2 Remove service port ...

Страница 14: ...in well Is the voltage in accordance with the rated voltage marked on the nameplate Is the electrical wiring and piping connection installed correctly and securely Has the ground connection been made securely to recommended earth ground points Is the power cord as specified Are the air inlet and outlet blocked Has the length of the connection pipe and the thermal capacity been verified Possible cons...

Страница 15: ...770x250x180 770x250x180 770x250x180 907x290x195 907x290x195 770x250x180 770x250x180 770x250x180 770x250x180 Net weight outdoor unit kg 32 32 40 59 59 65 72 71 71 Unit dimensions outdoor unit mm wxhxd 848x540x260 848x540x260 848x540x260 950x700x340 950x840x340 950x700x340 950x840x340 950x840x340 950x840x340 All of the above information may be changed without notice The specifications on the nameplat...

Страница 16: ...30 ...

Отзывы: