4

• Make sure you push the power plug all

the way into the socket. Failure to do so
can cause an electric shock, overheating
or even a fire.

• Do not remove the power plug while the

machine is operating except in an
emergency.

• Never use an extension cord or splice the

power cord.

• Never share the same power outlet with

another electric appliance.

• Do not insert the power plug into the

outlet with wet hands.

• Never insert fingers or objects into the air

intake or outlet vents.

• Do not aim chilled or heated air directly

onto the body for long periods.

• Disconnect the power supply

immediately if you smell burning or
smoke and contact your service center.

• Do not attempt to repair the air-

conditioner yourself.

• Consult with a professional electrician to

ensure that adequate circuit breakers,
fuses and other safety devices are in
place.

• Disconnect the unit whenever it will be

out of service for extended periods.

• Always disconnect the power supply

before cleaning the machine.

• Never pull on the cord to remove the

power plug.

• Do not place a space heater near the

air conditioner. Airflow from the air

Important safety information
Read all instructions before use

conditioner can cause incomplete
combustion in a space heater, resulting
in dangerous fumes.

• Keep combustible sprays away from the

unit.

• Ensure that the unit is mounted securely.
• Do not place objects on the unit.
• Never block the air intake or outlet vents.
• The indoor unit must be installed at least

2,0 m from the ground.

• Extreme temperature differentials can be

harmful to health.

• Do not use the air-conditioner for drying

clothes, preserving foods or other
functions for which it was not designed.

• Splashing water on the unit may cause

an electric shock and malfunction.

• The ground (earthing wire) must be

properly connected. Do not connect the
earth wire to a gas or water pipe,
lightning rod or telephone earth lines.

• The unit must be operated with a stable

voltage in the range of 198-253 Volts.

Name and function of parts

1. Surface panel 
2. Air filters and cleaners
3. Shell
4. Key switch

1

5.  Louver
6. Power plug

2

7. Drain hose
8. Wireless remote controller
9. Connection pipe

3

10. Air outlet cover

Air in

Air in

Air out

Air out

(1)

Not on models GE AIR 116, GE AIR 121, PRO AIR I109 and PRO AIR I112.

(2)

These models do not have a power plug on the indoor unit as they are powered through the outdoor unit:
GE AIR 218, GE AIR 224, GE AIR 326, GE AIR 428, PRO AIR 218. GE AIR 116 and GE AIR 121 are powered
through the indoor unit and do not have a power plug.

(3)

The following models have more than one indoor unit and two connection pipes. Models not mentioned
below have one indoor unit and two connection pipes.
- Two indoor units and four connection pipes for models GE AIR 218, GE AIR 224 and PRO AIR 218
- Three indoor units and six connection pipes for model GE AIR 326
- Four indoor units and eight connection pipes for model GE AIR 428

Owner’s Manual

WARNING!
Use this appliance only for its intended purpose as described in this Owner’s Manual

When using electrical appliances, basic safety precautions should be taken, including the
following:

Содержание GE AIR 107

Страница 1: ...Wall Mounted Split Air Conditioner Owner s Manual and Installation Instructions GE Consumer Industrial Appliances GE imagination at work English ...

Страница 2: ...How to insert batteries 10 User notices 10 Care and maintenance 11 Troubleshooting 13 Installation instructions 15 Accessories and installation diagram 15 General installation instructions 16 Installing the indoor unit s 18 Installing the outdoor unit 23 Test operation and after installation check 25 Technical specifications 27 Models covered in this document GE GE AIR 107 GE AIR 109 GE AIR 112 GE ...

Страница 3: ...alled at least 2 0 m from the ground Extreme temperature differentials can be harmful to health Do not use the air conditioner for drying clothes preserving foods or other functions for which it was not designed Splashing water on the unit may cause an electric shock and malfunction The ground earthing wire must be properly connected Do not connect the earth wire to a gas or water pipe lightning r...

Страница 4: ...0 C HEAT mode not available on models GE AIR 326 and GE AIR 428 3 MODE button Select the desired mode of operation by pushing this button The unit can operate on AUTO COOL DRY FAN or HEAT modes Heat mode not available on models GE AIR 326 and GE AIR 428 4 FAN button Press this button to change fan speed There are three speeds to choose from or set the FAN to AUTO to let the unit control the air flo...

Страница 5: ...control the speed of the indoor fan according to the target temperature HEAT mode operation not available on models GE AIR 326 and GE AIR 428 The microcomputer automatically controls the rate of heating It adjusts the operation of the unit according to the actual room temperature and the desired temperature If the room temperature is lower than the desired temperature the unit will heat the air of...

Страница 6: ...emperature to save energy Keep the room approximately 5 C cooler than the outside temperature when operating in COOL mode Adjust the direction of the airflow appropriately Remember that warm air rises and cool air sinks so adjust the louver downward for heating and upward for cooling to take advantage of natural convection currents User notices CAUTION Always turn power off and remove the power plu...

Страница 7: ...enter Please check for the following 1 Is a power connection loose 2 Is the circuit breaker activated 3 Is the voltage higher than 253 volts or lower than 198 volts 4 Is TIMER ON in operation 1 Is the set temperature suitable 2 Is the air inlet or outlet obstructed 3 Are the air filters dirty or clogged 4 Is the indoor fan speed set too low 5 Is there another heat source in the room 1 Is the remote...

Страница 8: ... 2 5 4 5 Tapping screw 10 10 20 30 40 Plastic drain hose 1 1 2 3 4 Piping hole sleeve 2 2 4 6 8 Wrapping tape 1 1 2 3 4 Connection piping 1 1 2 3 4 Thermal insulation hose 1 1 2 3 4 Outdoor drain elbow 1 1 2 Outdoor drain stem 2 2 4 Air cleaner 2 2 4 6 8 Square ring 1 2 2 2 Immediately stop all operations disconnect the power and contact your nearest service center in the event any of the followin...

Страница 9: ...er before beginning installation to avoid possible malfunctions When picking up and moving the unit be guided by trained and qualified personnel The ground connection of the air conditioner must be made correctly and securely to the recommended earth ground points Contact the service center if you have any question Installation in the following places may cause malfunction Any place where machine o...

Страница 10: ...ter 11 Do not install the unit in the immediate vicinity of a laundry bath shower or swimming pool 12 The power plug must be accessible after the appliance is correctly positioned Install the rear panel 1 Always mount the rear panel horizontally 2 Fix the rear panel on the selected location with the screws supplied with the unit 3 Be sure the rear panel is firmly fixed The mounting must be able to w...

Страница 11: ...d value to operate the air conditioner safely 7 Wiring work must conform to national standards Model GE AIR 107 GE AIR 109 GE AIR 112 PRO AIR 107 PRO AIR 109 PRO AIR 112 GE AIR 116 GE AIR 121 GE AIR 218 GE AIR 224 PRO AIR 218 GE AIR 326 GE AIR 428 PRO AIR I109 PRO AIR I112 Indoor terminal block N 2 4 5 ground N 2 3 4 5 N 2 3 ground N 1 2 3 ground N 1 2 3 ground Cable wire Blue black violet orange ...

Страница 12: ...the connecting cable when fixing it with the wire clamp Make sure the wires are securely connected to the terminal block and the connecting cable is firmly held by the wire clamp Installing the outdoor unit Fig 3 Pipe diameter Torque mm Nm 6 35 15 20 9 52 31 35 12 7 50 55 15 8 60 65 Table 3 Install the piping hole 1 Make the piping hole Ø100 mm for models GE AIR 116 and GE AIR 121 and Ø80 mm for all...

Страница 13: ...it is connected to the power grid or after a power cut AUTO TEST R U N STOP Air purging and leakage test For models with multiple indoor units this procedure must be executed for each indoor unit This procedure requires a manifold valve and a vacuum pump 1 Make sure the liquid side valve and gas side valve are set to the closed position and check pipes are connected properly 2 Remove service port ...

Страница 14: ...in well Is the voltage in accordance with the rated voltage marked on the nameplate Is the electrical wiring and piping connection installed correctly and securely Has the ground connection been made securely to recommended earth ground points Is the power cord as specified Are the air inlet and outlet blocked Has the length of the connection pipe and the thermal capacity been verified Possible cons...

Страница 15: ...770x250x180 770x250x180 770x250x180 907x290x195 907x290x195 770x250x180 770x250x180 770x250x180 770x250x180 Net weight outdoor unit kg 32 32 40 59 59 65 72 71 71 Unit dimensions outdoor unit mm wxhxd 848x540x260 848x540x260 848x540x260 950x700x340 950x840x340 950x700x340 950x840x340 950x840x340 950x840x340 All of the above information may be changed without notice The specifications on the nameplat...

Страница 16: ...30 ...

Отзывы: