CONFIGURING THE XC-RP300
The XC-RP300 is factory configured to customer default specification before shipment. Configuration
options are in tables 2 and 3.
To configure the XC-RP300 in the field you will need an adapter
cable, a PC with a serial port and the 10BaseS GUI software
tool. The 10BaseS GUI is available from GDI Communications.
Please contact GDI Communications to obtain this software tool.
The adapter cable information can be found in Appendix C. The
PC will need to have a serial port or conventional USB serial port
adaptor and be running a Windows 98 or later operating system.
Connect the PC to the console port on the XC-RP300. Set the
console select switch to the SEC (Secondary) position. Using an
in-line attenuator, connect the Primary VDSL port to the
Secondary VDSL port. The VDSL Sync LED on both the Primary
and Secondary should illuminate. Open the GUI by double
clicking on the 10BaseS icon. The “Startup” dialogue box will
appear. Select the COM port for your PC.
After the GUI comes up it will show the “General Settings” screen.
Select the Link Configuration tab. It will show the
present configuration in the selected modem.
From the Rate table, select the new rate you
want to configure. From the table determine the
(Downstream) DS Interpolation, DS
Constellation and DS Carrier Frequency. Make
the desired changes.
Determine the (Upstream) US Interpolation, US
Constellation, and US Carrier Frequency. Make
the desired changes.
Click on the Write & Update button.
The Write & Update Dialogue box will appear.
Click on OK. Observe the following: the update
process will begin, and the VDSL Sync LED will
turn OFF. When the update process is
completed the VDSL sync LED should illuminate
again.
The configuration information displayed will
update with the latest configuration.
Note: The link configuration can only be changed
from an LT unit.
Figure 13
Link Configuration Tab
Figure 12
Startup dialog box
10