6. APPLY UPGRADE PACKAGE 2
Case 1:
If the system (server/IMB/projector) is already a SX-2000(A/T)R system, please ensure the
system (server/IMB/projector) is able to playback a DCP from the server right before applying the
incremental upgrade to a newer build version.
This is to guarantee IMB will be able to access the server storage (no matter through server
eth1 or server eth2) successfully for some upgrade files.
Server eth2 is available when the additional gigabit network card is installed in the server
(section 4).
If the IMB is not able to access the server storage during the incremental upgrade, i.e. without checking
that the system is able to playback a DCP from the server, the upgrade may fail and the IMB LED will
display a RED color after reboot. When this happens, only a GDC authorized personnel can recover the
system.
Case 2:
When converting the SX-2000A server to work with HFR IMB, please ensure the incremental
upgrade package version is the same as the IMB build version.
e.g.
if the IMB build version is build55 and the incremental upgrade package version is given as build56,
please request build55 upgrade package when converting the SX-2000A server to work with the IMB of
version build55. After successfully converting the server and IMB, then follow case 1 to update to a
newer build 56.
Figure 5 Apply package 2.
1
After reboot, go to SMS->Configuration->Assistance->USB Disk again.
2
Apply package 2 as indicated in Figure 5.
3
Same as Section5.2, reboot the server after the upgrade.